COMPARISON OF PLASMA-INDUCED SURFACE DAMAGES IN VARIOUS PLASMA SOURCES

  • Yi, Dong-Hyen;Lee, Jun-Sik;Kim, Sang-Kyun;Kim, Jae-Jeong
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.338-344
    • /
    • 1996
  • This study was an investigation of plasma-induced damages on silicon substrate in the semiconductor manufacturing technology. The plasma-induced damage level on silicon substrate was analyzed and compared in various plasma etching systems. The analysis methods were therma wave, life-time recovery, SCA (Surface Charge Analyzer) and TRXF (Total Reflection X-ray Fluorescence) measurements, and the measured values were compared for each systems. In the comparison of the values which were obtained by a system that had low life-time recovery, there was not any differences in DC parameters. However, the reflesh time distribution of device of that system had decreased about 10 to 20m sec compared to a system which had high life-time recovery.

  • PDF

Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구 (A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe)

  • 손의정;김동현;이호준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

Circulating Plasma and Exosomal microRNAs as Indicators of Drug-Induced Organ Injury in Rodent Models

  • Cho, Young-Eun;Kim, Sang-Hyun;Lee, Byung-Heon;Baek, Moon-Chang
    • Biomolecules & Therapeutics
    • /
    • 제25권4호
    • /
    • pp.367-373
    • /
    • 2017
  • This study was performed to evaluate whether microRNAs (miRNAs) in circulating exosomes may serve as biomarkers of drug-induced liver, kidney, or muscle-injury. Quantitative PCR analyses were performed to measure the amounts of liver-specific miRNAs (miR-122, miR-192, and miR-155), kidney-specific miR-146a, or muscle-specific miR-206 in plasma and exosomes from mice treated with liver, kidney or muscle toxicants. The levels of liver-specific miRNAs in circulating plasma and exosomes were elevated in acetaminophen-induced liver injury and returned to basal levels by treatment with antioxidant N-acetyl-cysteine. Circulating miR-146a and miR-206 were increased in cisplatin-induced nephrotoxicity and bupivacaine-induced myotoxicity, respectively. Taken together, these results indicate that circulating plasma and exosomal miRNAs can be used as potential biomarkers specific for drug-induced liver, kidney or muscle injury.

Vitamin B6 결핍이 Streptozotocin 유발 당뇨 흰쥐의 에너지 대사물 농도에 미치는 영향 (The Effect of Vitamin B6 Deficiency on Energy Metabolite in Streptozotocin-induced Diabetic Rats)

  • 주윤옥
    • Journal of Nutrition and Health
    • /
    • 제27권3호
    • /
    • pp.228-235
    • /
    • 1994
  • The purpose of this study was to investigate the effect of vitamin B6 deficiency on the concentration of energy metabolite in streptozotocin-induced diabetic rats. Thirty rats were fed a vitamin B6 deficient diet(-B6) or a control diet(+B6) for 5 weeks and then subdivided into 3 groups respectively ; base group, one day diabetic group and three day diabetic group. Diabetes of rats were induced by streptozotocin injection into the tail vein. Glucose, glycogen, protein, alanine, triglyceride and free fatty acids were compared in plasma, liver skeletal muscle of rats. Also, the total urinary nitrogen and glucose excretion were compared. Compared with +B6 rats, the increase of plasma glucose in -B6 rats due to the diabetes was smaller. After diabetes was induced, the level of plasma alamine was not changed in -B6 rats while increased significantly(p<0.05) in +B6 rats. The increase of urinary nitrogen excretion was smaller and the increase of muscle protein was larger in -B6 rats at the first day diabetes was induced. The levels of plasma free fatty acid and liver triglyceride were significantly (p<0.05) higher in -B6 rats after diabetes was induced. These results suggest that vitamin B6 deficiency may impair the adaptation of animals to the energy metabolism related due to a decrease of the body protein catabolism of fatty acid oxidation in diabetes and aggravate fatty liver which is one of the chronic complications of diabetes.

  • PDF

Pharmacokinetics of Acebutolol and Its Main Metabolite, Diacetolol After Oral Administration of Acebutolol in Rabbits with Carbon Tetrachloride-Induced Hepatic Failure

  • Choi, Jun-Shik;Burm, Jin-Pil
    • Archives of Pharmacal Research
    • /
    • 제25권4호
    • /
    • pp.541-545
    • /
    • 2002
  • Pharmacokinetic characteristics of Acebutolol and its main metabolite, diacetolol, following a single 10 mg/kg oral dose, were investigated in rabbits with carbon tetrachloride-induced hepatic failure. Plasma concentrations of acebutolol and diacetolol were determined by a high performance liquid chromatography assay. The area under the plasma concentration-time curves (AUC) and maximum plasma concentration ($C_{max}$) of acebutolol were significantly increased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. The ratio of the diacetolol to total acebutolol in plasma (i.e., metabolite percentage rate) was significantly decreased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. Volume of distribution ($V_{d}$) and total body clearance ($CL_{t}$) of acebutolol were significantly decreased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. Slope of terminal phase ($\beta$) of acebutolol was significantly decreased in hepatic failure rabbits. These findings suggest that the $V_{d},{\;}CL_{t}$ and $\beta$ of acebutolol were significantly decreased as a result of inhibition of the hepatic metabolism in moderate to severe hepatic failure rabbits. Therefore, dose adjustment may be necessary for acebutolol in hypertensive patients with hepatic damage.

Effects of stress on scuticociliate killing activity of olive flounder (Paralichthys olivaceus) plasma in relation to humoral immunity

  • Kwon, Se-Ryun;Kim, Chun-Soo;Kim, Ki-Hong
    • 한국어병학회지
    • /
    • 제15권2호
    • /
    • pp.77-82
    • /
    • 2002
  • Effects of stress-induced suppression of humoral immunity on scuticociliate killing activity of olive flounder plasma were investigated. Changes in glucose level. alternative complement activity and Iysozyme activity of plasma by handling stress were analysed in relation to in vitri parasiticidal activity of plasma. The plasma glucose level was about two times higher in fish after a handling stress than in control fish. Plasma lysozyme activity and natural haemolytic activity were decreased in suessed fish.The scuticociliate killing activity of plasma was significantly lower in stressed fish than in non-stressed control fish. The present results indicated that stress-induced immunodepression could be a cause of scuticociliatosis occurrence in olive flounder.

레이저 유도 플라즈마에 대한 자기장 감금의 영향 연구 (Research on the magnetic confinement of laser-induced plasma)

  • 현은주;김용현
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.38-45
    • /
    • 2024
  • 간단한 자기장 감금이 레이저 유도 플라즈마의 전하 입자들에 미치는 영향이 논의 되었다. 자기장 영향에 대한 이전 연구들은 주로 플라즈마 방전 세기의 향상이나 수명시간 연장에 집중되었다. 이와 대조적으로, 본 개발은 과거에 거의 다뤄지지 않았던, 플라즈마 소멸에 대해 연구하였다. 이는 플라즈마를 활용한 기술개발에 혁신적인 도움이 될 것으로 기대한다. Nd:YAG 레이저(1064 nm, 6 ns)가 3가지 타입의 금속 물질(Al, Ti, STS)과 공기 중에 집광되었다. Nd2Fe14B 자석으로 0.4T 크기의 자기장을 만들었고, 이를 레이저 유도 플라즈마에 관통시켰다. 플라즈마 스펙트럼은 레이저 파워와 분광기의 딜레이 타임을 조정해 가면서 자기장 여부에 따른 수치가 측정되었다. O I(777.42 nm), Fe I (520.447 nm), Ti I (503.649 nm), Al I (396.147 nm) 스펙트럼 분석을 통해 자기장에 의한 플라즈마의 소멸이 특정 조건에 상관없이 항상 촉진됨을 독점적으로 발견하였다.

Ion-induced secondary electron emission coefficient and work function for MgO thin film with $O_2$ plasma treatment

  • Jung, J.C.;Jeong, H.S.;Lee, J.H.;Oh, J.S.;Park, W.B.;Lim, J.Y.;Cho, J.W.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.525-528
    • /
    • 2004
  • The ion-induced secondary electron emission coefficient ${\gamma}$ and work function for MgO thin film with $O_2$ plasma treatment has been investigated by ${\gamma}$ -FIB (focused ion beam) system. The MgO thin film deposited from sintered material with $O_2$ plasma treatment is found to have higher ${\gamma}$ and lower work function than those without $O_2$ plasma treatment. The energy of various ions used has been ranged from 100eV to 200eV throughout this experiment. It is found that the highest secondary electron emission coefficient ${\gamma}$ has been achieved for 10 minutes of $O_2$ plasma treatment under RF power of 50W.

  • PDF

자동차용 강판의 겹치기 $CO_2$ 레이저 용접에서 발생되는 플라즈마 특성에 관한 연구 (Study on the characteristics of the plasma induced by lap-joint $CO_2$ laser welding of automotive steel sheets)

  • 남기중;박기영;이경돈
    • 한국레이저가공학회지
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 2002
  • In order to investigate the characteristics of the plasma induced by lap-joint CO$_2$ laser welding of automotive steel sheets, the effects of welding speed, shield gas flow rate, gap size, and laser beam defocus to plasma intensity emitted from keyhole have been investigated. The plasma light is measured by fiber and photodiode. Also, the plasma images were captured by the high speed digital camera in 1000frames/sec in order to correlate the plasma light signal with plasma pattern. From the results, it is observed that the difference of the plasma intensity for between the deep penetration and partial penetration exists from 1.2 to 2 times. The plasma light intensity decreased in case of the deep penetration Is observed due to the exhausting of the plasma gas under the sheet. On the other hand, under the conditions of the deep penetration, the plasma intensity is significantly increased by controling the conditions decreasing the penetration depth. It was specially founded that the effect of 0.3mm gap size at partial penetration condition is approximately similar to deep penetration in 0mm gap. It is concluded that the plasma intensity is able to evaluate the penetration depth in lap-joint welding and appears to offer the most straightforward correlation to the welding process.

  • PDF

알루미늄 합금의 레이저 용접시 유기하는 플라즈마의 스펙트럼 분석 (Spectral Analyses of Plasma Induced by Laser Welding of Aluminum Alloys)

  • 김종도;최영국;김영식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.292-300
    • /
    • 2001
  • The paper describes spectroscopic characteristics of plasma induces in the pulsed YAG laser welding of alloys containing a large amount of volatile elements. The authors have conducted the spectroscopic analyses of laser induced Al-Mg alloys plasma in the air and argon atmosphere. In the air environment, the identified spectra were atomic lines of Al, Mg, Cr, Mn, Cu, Fe and Zn, and singly ionized Mg lines, as well as the intense molecular spectra of A10 and Mg0 formed by chemical reactions of evaporated Al and Mg atoms from the pool surface with oxygen in the air. In argon atmosphere, Mg0 and AI0 spectra vanished, but AIH spectrum was detected. The hydrogen source was presumably hydrogen dissolved in the base metals, water absorbed on the surface oxide layer, or $H_2$ and $H_2O$ in the shielding gas. The resonant 1ines of Al and Mg were strongly self-absorbed, in particular, self-absorption of the Mg 1ine was predominant. These results show that the laser induced plasma was made of metal1ic vapor with relatively low temperature and high density.

  • PDF