• 제목/요약/키워드: Indoor-outdoor air quality

검색결과 172건 처리시간 0.025초

교사 내 플랜트 모델 유형별 적용에 따른 공기질 변화 (Changes in Air Quality through the Application of Three Types of Green-Wall Model within Classrooms)

  • 양호형;김형주;방성원;조흔우;이형석;한승원;김광진;김호현
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.295-304
    • /
    • 2023
  • Background: Adolescents are relatively more sensitive than adults to exposure to indoor pollutants. The indoor air quality in classrooms where students spend time together must therefore be managed at a safe level because it can affect the health of students. Objectives: In this study, three types of green-wall models were applied to classrooms where students spend a long time in a limited space, and the resulting effects on reducing PM were evaluated. Methods: In the middle school classrooms which were selected as the experimental subjects, IoT-based indoor air quality monitoring equipment was installed for real-time monitoring. Three types of plant models (passive, active, and active+light) were installed in each classroom to evaluate the effects on improving indoor air quality. Results: The concentration of PM in the classroom is influenced by outdoor air quality, but repeated increases and decreases in concentration were observed due to the influence of students' activities. There was a PM reduction effect by applying the green-wall model. There was a difference in PM reduction efficiency depending on the type of green-wall model, and the reduction efficiency of the active model was higher than the passive model. Conclusions: The active green-wall model can be used as an efficient method of improving indoor air quality. Additionally, more research is needed to increase the efficiency of improving indoor air quality by setting conditions that can stimulate the growth of each type of plant.

업무용 빌딩 소재 사무실의 실내환기 평가 (Assessment of indoor ventilation in commercial office buildings)

  • 정지연;이광용;이병규
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.

구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정 (Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model)

  • 양원호;손부순;손종렬
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

인천지역 일부 학교의 실내 및 대기 중 포름알데히드 농도 평가 (Assessment of Formaldehyde Concentration in Indoor and Outdoor Environments of Schools in Incheon)

  • 정연희;최상준
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.372-378
    • /
    • 2007
  • This study evaluated formaldehyde concentration in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. These schools were chosen based on their surrounding environments that included industrial site, landfill, railway, 8-lane road and harbor. Indoor concentration ranged between 4.65 and $56.25{\mu}g/m^3$, while that of outdoor concentration was $1.23{\sim}10.22{\mu}g/m^3$, both of which were below $100{\mu}g/m^3$, a formaldehyde criterion stipulated by the School Health Act. Indoor concentration was higher than outdoor concentration by $1.4{\sim}5.9$ times, and there was a positive correlation between indoor and outdoor formaldehyde concentrations (R=0.49). As for indoor concentration, multi-use practice rooms had an average 2.8 times higher than that of usual classrooms with a statistically significant difference (p<0.01). Indoor formaldehyde concentration had a positive correlation with the construction year (R=0.55). The school close to the industrial complex had the highest ambient formaldehyde concentration, followed by the one near a landfill. The formaldehyde concentration in school in the vicinity of the industrial complex was twice or more than that of the school located other site. In conclusion, this study suggests that it is crucial to consider surrounding environments in selecting school sites, as it can influence ambient air contamination, as well as using construction material that emit less formaldehyde, in order to protect the health of students, teachers and school staff.

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인 (Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces)

  • 박희은;박정호;김형갑
    • 한국산업보건학회지
    • /
    • 제22권2호
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

미생물을 이용한 일부 병원, 가정 및 일반 대기질의 평가 (Assessment of Indoor and Outdoor Air Quality through Determination of Microorganism)

  • 하권철;백남원
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.73-81
    • /
    • 1991
  • To assess biological air quality, concentrations of viable airborne microbes were determined in hospital home and outdoor air from August 25 to October 18, 1990. Bacteria, fungi and thermophilic bacteria were sampled using gravitational and suctional sampling method. In bacteria groups, the Staphylococcus spp. was identified by microscopic examination and biochemical tests. Results of the study are as follows. 1. Results using the gravitational sampling method indicated that average numbers of airborne microbes in hospital home and outdoor air were 21.5, 12.2 and 17.6 CFU/plate, respectively. These levels are well within an appropriate standard of 50 CFU/plate suggested by Endo. 2. Results using the suctional sampling method indicated that total airborne microbe concentrations in hospital, home and outdoor air were 1,998, 1,363 and $1,880CFU/m^3$, respectively. All of the results were within the recommended remedial action level, $10,000CFU/m^3$ of the American Conference of Governmental Industrial Hygienists(ACGIH). 3. Concentration of thermophilic bacteria in hospital and outdoor air were 79 and $111CFU/m^3$, respectively. Thermophilic bacteria were not detected in the home air. These results were within the remedial action level, $500CFU/m^3$. 4. Concentrations of Gram negative bacilli in holpital home and outdoor air were 20.3, 23.6 and $16.8CFU/m^3$, respectively. all were within the remedial action level, $500CFU/m^3$, recommended by ACGIH. 5. Concentrations of Staphylococcus spp. in hospital, home and outdoor air were 34.8, 14.7, and $22.4CFU/m^3$. respectively. all were within the remedial action level, $75CFU/m^3$, recommended by ACGIH. The percentages of Staphylococcus spp. in total bacteria in hospital, home and outdoor air were 19.0, 10.2 and 14.5%, respectively.

  • PDF

공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 - (A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA -)

  • 윤성훈
    • 한국실내디자인학회논문집
    • /
    • 제18권4호
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.

광촉매 활용 광투과 노출콘크리트 블록 및 거푸집 개발 (Photocatalyst Applied Light Transparent Exposed Concrete Block and Mold Development)

  • 서승훈;강영언;전승헌;권시원;김병일
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.16-17
    • /
    • 2018
  • A few years ago, the rapid degradation of domestic air quality has led to the efforts of exhaust gas policy and fine dust mask, but it is not a fundamental measure. In Korea, photocatalyst will be applied to residential and multi-use facilites to purify indoor and outdoor air. Also, in this study, it is tried to produce exposed concrete that is aesthetically pleasing as well as air purification of indoor by combining with light transparent concrete according to the increasing interest in human indoor living environment. For this purpose, we have developed a block formwork for photocatalysis light transparent concrete and established a suitable manufacturing method for on-site construction.

  • PDF

산화마그네슘 기반 규조토를 활용한 흡착형 경화체의 물리적 특성 (Physical Properties of Magnesium Oxide-Based Adsorption Matrix using Diatomite)

  • 이원규;경인수;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2019
  • Korea has defined fine dust as a social disaster as the problem of fine dust and air pollution becomes serious. Fine dust is classified as class one carcinogens because it is harmful to human body. When fine dusts enter the human body, they cause bronchial and skin diseases such as respiratory allergies, irritable pneumonia, asthma and atopy. As the air pollution becomes serious, the government is demanding measures to reduce fine dust. The polluted air in the outdoor is introduced into the room, thereby increasing the pollution degree of the indoor air quality. In this study, an adsorption type matrix for the improvement of indoor air quality was produced. Magnesium oxide and magnesium chloride were used as binders and diatomaceous earth was used as a adsorption material.

  • PDF

30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구 (An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance)

  • 노지희;박상현;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.