Abstract

This study evaluated formaldehyde concentration in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. These schools were chosen based on their surrounding environments that included industrial site, landfill, railway, 8-lane road and harbor. Indoor concentration ranged between 4.65 and $56.25{\mu}g/m^3$, while that of outdoor concentration was $1.23{\sim}10.22{\mu}g/m^3$, both of which were below $100{\mu}g/m^3$, a formaldehyde criterion stipulated by the School Health Act. Indoor concentration was higher than outdoor concentration by $1.4{\sim}5.9$ times, and there was a positive correlation between indoor and outdoor formaldehyde concentrations (R=0.49). As for indoor concentration, multi-use practice rooms had an average 2.8 times higher than that of usual classrooms with a statistically significant difference (p<0.01). Indoor formaldehyde concentration had a positive correlation with the construction year (R=0.55). The school close to the industrial complex had the highest ambient formaldehyde concentration, followed by the one near a landfill. The formaldehyde concentration in school in the vicinity of the industrial complex was twice or more than that of the school located other site. In conclusion, this study suggests that it is crucial to consider surrounding environments in selecting school sites, as it can influence ambient air contamination, as well as using construction material that emit less formaldehyde, in order to protect the health of students, teachers and school staff.

Keywords

References

  1. Levy, J. I., Lee, K., Spengler, J. D. and Yanagisawa, Y. : Impact of residential nitrogen dioxide exposure on personal exposure: an international study. Journal of the Air & Waste Management Association, 48, 553-60, 1998 https://doi.org/10.1080/10473289.1998.10463704
  2. EPA: Indoor air quality(IAQ) tool for school, IAQ coordinator's guide. 2nd ed, EPA, 2000
  3. NRC: Formaldehyde and other aldehydes. National Academy Press, National Research Council, National Academy of Sciences, Committee on Aldehydes, Board on Toxicology and Environmental Health Hazards, 1981
  4. International Agency for Research on Cancer(IARC): IARC monographs Vol. 88 formaldehyde, 2-butoxyethanol and 1-tert-butoxy-2-propanol. IARC, Lyon, France, 2005
  5. 노동부 : 화학물질 및 물리적인자의 노출기준. 노동부 고시 제2007-25호, 2007
  6. 환경부 : 다중이용시설등의 실내공기질 관리법 시행규칙 제3조 별표 2. 실내공기질유지기준. 환경부령 제 201호, 2006
  7. 교육인적자원부: 학교보건법 시행규칙 제3조 별표 4의 2. 교사안에서의 실내공기질 유지.관리기준. 교육인적자원부령 제905호, 2007
  8. WHO : Air quality guidelines. 2nd ed, Formaldehyde Chapter 5.8, 2001
  9. Lee, S. C., Guo, Hai., Li, W. and Chan, L. : Intercomparison of air pollutant concentrations in different indoor environments in Hong Kong. Atmospheric Environment, 36, 1929-1940, 2002 https://doi.org/10.1016/S1352-2310(02)00176-0
  10. 김윤신, 김미경 : 실내외 포름알데히드 농도에 관한 조사연구. 한국환경보건학회지, 15(2), 1-9, 1989
  11. 하권철 : 경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성. 한국환경보건학회지, 30(5), 353-357, 2004
  12. 윤충식, 정지연, 이광용, 박동욱, 박두용 : 유아교육시설의 위치 및 실내 . 실외에 따른 포름알데히드 농도변화. 한국환경보건학회지, 30(3), 259-263, 2004
  13. 환경부: 실내공기질관리 업무편람 2004. 2004
  14. National Institute for Occupational Safety & Health(NIOSH): NIOSH manual of analytical methods. 4th ed, DHHS(NIOSH), Method No. 2016, 3rd Supplement 2003-154, 2003
  15. Matthews, T. G., Funga, K. W., Tromberg, B. J. and Hawthorne, A. R. : Surface emission monitoring of pressed-wood products containing urea-formaldehyde resins. Environment International, 12(1-4), 301-309, 1986 https://doi.org/10.1016/0160-4120(86)90002-4
  16. 심상효, 김윤신: 신축공동주택의 실내공기질 특성 및 평가-휘발성 유기화합물 및 포름알데히드 중심으로. 한국환경보건학회지, 32(4), 275-281, 2006