• Title/Summary/Keyword: Indoor-outdoor air quality

Search Result 172, Processing Time 0.027 seconds

Indoor and Outdoor Air Quality and Its Relation to Allergic Diseases among Children: A Case Study at a Primary School in Korea

  • Kim, Ho-Hyun;Kim, Chang-Soo;Lim, Young-Wook;Suh, Min-A;Shin, Dong-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.3
    • /
    • pp.157-165
    • /
    • 2010
  • The purpose of this study is to investigate allergic diseases related to allergy caused by the exposure to indoor and outdoor sources of air pollution in primary schools. The symptoms questionnaire of allergic diseases based on the International Study of Asthma and Allergies in Childhood (ISAAC) was completed by the participants. The past and present status of asthma, allergic rhinitis, eczema, and allergic conjunctivitis were investigated by providing a questionnaire to all the participating children. Questionnaires were sent to a total of 61,350 children from 438 primary schools. A total of 40,522 children responded to the questionnaire, which represents a 66.1% return rate. Volatile Organic Compounds (VOCs), $\underline{A}$ldehydes, and Particulate Matter ($PM_{10}$) were measured and analyzed from October to December of 2006, in 82 primary schools. The final study population comprised 35,168 children with complete data which excluded incomplete questionnaire responded by 5,354 children. Based on the survey, the level of indoor air contamination did not appear to be high, but 27.2% of the schools evaluated had exceeded the $PM_{10}$ level specified by the school health guidelines ($100\;{\mu}g/m^3$). The overall mean concentration of formaldehyde was $22.07\;{\mu}g/m^3$ and 1.0% of schools (1 school) exceeded the $100\;{\mu}g/m^3$. Statistically significant relationships have been observed between indoor air quality and prevalence rate of allergic rhinitis and conjunctivitis of primary schools in Korea.

Performance Evaluation of Heat Exchangers due to Air-side Particulate Fouling in the Air Conditioners (공기측 파울링에 의한 에어컨 열교환기의 성능분석 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.447-453
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the cooling performance and pressure drop on the air-side particulate fouling of heat exchangers for air conditioners. Air conditioners being used in the field such as inn, restaurant, and office are collected in chronological used order. Test results show 15% decrease of the cooling capacity and 44% increase of the pressure drop for the 7 years air conditioners used in the seaside inn.

A study on the finishing materials for Reduction of Indoor pollution (실내 환경오염 감소를 위한 건축마감 재료에 관한 연구)

  • Kim, Ja-Kyung;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.303-313
    • /
    • 2007
  • Nowadays, according to many studies, indoor space's pollution level is two to ten times higher than outdoor space's. This result arouses our attention. The major causes of deterioration of indoor air quality are the lack of ventilation caused by draught-proofing and insulation construction, and harmful chemical substances emitted from building materials, office machine and furniture. Therefore, we are continuing research to find the method for healthful house and production of many forms of well-being goods. However, because of exaggerated advertisements and the lack of accurate information, consumers choose the products whose performance is not verified. Therefore, this study investigates the actual conditions of pollution by building materials and the extent of the health damage by this pollution, and suggests the method for minimizing indoor pollution in aspect of indoor environment control and the use of environment friendly materials. But the building materials presented in this study are limited to the environment friendly construction materials that are in circulation In domestic market because this research is primarily aimed to give domestic consumers the standard for selecting this materials.

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter (겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염)

  • Kim, Jong Bum;Lee, Gwangjae;Ryu, Sung Hee;Lee, Jae Young;Woo, Sung-Ho;Lee, Seung-Bok;Kim, Kyung Hwan;Yun, Seong-Taek;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City (부산광역시 지하철 내의 대기오염도 분석)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • Journal of Environmental Science International
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.

Indoor environmental alarm robot (실내환경 오염 측정장치 알람봇 구현)

  • Cho, Hae-Jin;Lee, Hye-bin;Lee, Gi-Ho;Oh, Min-u;Choi, Ji-Seung;Kim, Su-Min;Kim, Seong-Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.549-551
    • /
    • 2016
  • In this paper, With the development of modern science and technology are Sheds to stay indoors rather than outdoors space it increased significantly compared to the past. And a wide variety of research about outdoor air quality until recently, efforts are underway but the issue of air quality in the room is the fact that all considered relatively lightly. As the contamination of the room air is polluted, unlike the natural environment, a large outdoor air dilution rate, the dilution rate is very low, once the contaminated air continuously circulating exerts a very bad influence on the health of people staying in the room. In this study, movement characteristics of the person living in a room, the air measuring device for the study of the active indoor environmental control system reflects the life form to measure the quality of the measured air in real time for transmitting the information to the user of the smart devices, alarm bot It was implemented and operational applications.

  • PDF

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF

A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness (차음성능과 기밀성능이 향상된 경량 간막이벽 개발)

  • 배상환;박진우;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF