• 제목/요약/키워드: Indoor thermal comfort

검색결과 243건 처리시간 0.026초

전남지방 전통주택의 하절기 온습도 측정 및 주관평가에 관한 실험적 연구 (An Experimental Study on the Thermal Environmental Measurements and Subjective Reponses in Summer Season for the Korean Traditional Houses in Chonnam Province)

  • 김선우;이태강;김형렬
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.41-46
    • /
    • 2006
  • This study aims to analyzed thermal comfort characteristics and subject response for thermal environment of Korean traditional houses.. The air temperature and humidity in the living area of the residence were measured in during a day. And the subject response were surveyed to evaluate of controling the thermal environment factor (temperature, humidity, comfort) of the korean traditional houses. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls. And environmental control for the air temperature and humidity is estimated considerably satisfactory.

치환환기되는 실내에 있어서 인체주변의 기류 및 온열환경 특성에 대한 검토 (Examination of Airflow and Thermal Environment Characteristic around Human Body in a Room with Displacement Ventilation)

  • 양정훈
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.299-306
    • /
    • 2007
  • Recently, the numerical analysis using person shape model for CFD (Computational Fluid Dynamic) has been researched widely for the thermal comfort and inhaled air quality of human body in the indoor environments. The purpose of this research is to examine the characteristic of airflow and thermal environment around human body by the experiment of displacement ventilation that assumes the indoor environment of natural convection. In this study, thermal manikin was used instead of real human body. The Airflow characteristic around human body was measured in precision by PIV (Particle Image Velocimetry). This experimental result will be used as data for CFD benchmark test using person shape model.

겨울철 난방시 아파트 구조체의 축방열 특성에 대한 연구 (A Study on Characteristics of Heat Storage and Emission of Apartment Structures in Winter Season)

  • 조근제;장현재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.208-213
    • /
    • 2011
  • In the former study, it is obtained that thermal storage effect of the apartment structure is the disadvantage to maintain comfort indoor thermal environment. However, because the thermal storage effect can be changed of its aspect in heating season, field measurement at the same apartment with the measurement in summer season was conducted in winter season. As results, thermal storage effect of apartment structure was the disadvantage in winter season, too.

  • PDF

소형아파트의 방위에 따른 실내온열환경 실태와 평가 (Thermal Environment of Small-size Apartments Facing in Two Different Directions)

  • 최윤정
    • 대한가정학회지
    • /
    • 제31권3호
    • /
    • pp.213-222
    • /
    • 1993
  • The purpose of this study was to investigate the present conditions of thermal environment in small-size apartments. The research methods used were measuring of environmental elements and personal self-administration for the residents' thermal comfort responses. The house subjected were 25 peung apartments facing southeast and southwest directions. The results of this study were summarized as follow ; The indoor temperature and humidity of houses subjected were 25.0∼27.3℃, 37.1∼42.5%. Compared with the distribution of indoor temperature and globe temperature of houses subjected, those of southeast house were more stable. And in the residents' thermal sensation responses, the residents of southeast houses checked more often neutral zone. Therefore the thermal environment of southeast houses were more comfortable condition than southwest houses.

  • PDF

거주후 평가를 통한 공동주택의 실내환경 성능평가요소 분석에 관한 연구 (An Analysis of Performance Assessment Factors of Indoor Environmental Quality in Multi-Family Housing Using Post Occupancy Evaluation)

  • 이시내;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.128-134
    • /
    • 2011
  • The objective of this study is to analyze the major factors of indoor environment that affect the satisfaction of the occupancy in multi-family residential buildings. The results of this study can contribute to improving the comfort of the residents effectively as they are applied preferentially at the design and construction stages. The indoor environment factors investigated for the analysis included thermal, light, air and the acoustic environment. The individual factors were derived from the 'indoor environment' assessment indices of the green building certificate systems of various countries. Based on these, a questionnaire was prepared to conduct the Post Occupancy Evaluation. The survey results were statistically analyzed.

신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발 (Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks)

  • 김형중;두석배;신중린;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토 (Study on Indoor Thermal Environment Controlled by Portable Cooler)

  • 최동균;송두삼;김중호
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구 (A study on the comfort thermal environment by the Draft in floor panel heating system)

  • 이경희
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

Granulated PCM(G-PCM)소재의 열적성능 평가에 관한 실험적 연구 (Experimental Study on Thermal Performance Evaluation of Granulated PCM(G-PCM))

  • 정유건;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.265-266
    • /
    • 2012
  • Recently, preparing countermeasures about energy depletion and CO2 emission progressing rapidly is considered as an urgent problem not only in domestic country but also in international countries. Among this, the requirement for the comfort development of in door environment is increasing according to housing culture and life environment changing. Thus, it is required urgently to save building energy and develop fusion technology maintaining comfort of indoor environment. Recently, energy-saving ways in saving heating and cooling energy by latent heat and thermal storage is considered significantly. In this study, keeping up with the times, thermal performance analyzed. Also, this study has the aim to draw materials for evaluating usefulness and efficiency.

  • PDF

하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.