Measurement Examination of Indoor Thermal Environment Characteristic in accordance with Heat Loads from Occupant for Large Enclosure in Winter (인체부하를 고려한 대규모 실내경기장의 동계 온열환경 특성 실측조사)

  • Seok, Ho-Tae;Chae, Mun-Byoung;Choi, Dong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.97-107
    • /
    • 2007
  • The purpose of this study is to grasp the characteristic of indoor thermal environment from large enclosures in connection with heating condition and outdoor environment. This study has measured indoor thermal environment in accordance with heat loads from occupant for large enclosures in winter. We examined indoor thermal environment of the large enclosures in this study which include temperature distribution vertical, horizontal, seat and surface and thermal comfort environment.

  • PDF

The Analysis for Thermal Comfort Evaluation during long time operating Air Conditioner (에어컨 장시간 운전시 온열쾌적감 평가에 관한 연구)

  • Kim, Dong-Gyu;Park, Jong-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.59-64
    • /
    • 2007
  • Using air conditioner has been increased in home or office buildings in summer. Also various problems related to air conditioning such as disease induction happened by using air conditioner excessively and operating long. Active operation control is needed for occupant's health when air conditioner operates long. We should think ahead to acquire thermal comfort of occupants which represents psychological and physiological reaction for this operation. Research has been progressed to observe activity of autonomic nervous system by trying to quantitate change of thermal comfort. In this study, questions of the subject and change of body's autonomic nervous system were chosen to evaluate thermal comfort during operation of air conditioner for a long time. Electrocardiogram and questions of the subject which is the progress of changing TSV and CSV by occupants indoor were measured when room air conditioner is operated for a long time, and an air-conditioned adaptability of human body was evaluated by acquiring the change rate of autonomic nervous system through analyzing HRV. As a result of the evaluation, change rate of body's autonomic nervous system corresponded to votes of the subject's question generally, but was distinguished from analysis result of warm-cold sensation in a low temperature area.

Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements (PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계)

  • Sung, Jae-Yong;An, Kwang-Hyup;Lee, Gi-Seop;Choi, Ho-Seon;Lee, In-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) (개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가)

  • 최익순;정광섭;박영철;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

A Study of Thermal Comfort by Winter Temperature Humidity Change (겨울철 온도 및 습도변화에 따른 온열쾌적감에 관한 연구)

  • Kim, Se-Hwan;Lee, Sung;Kim, Dong-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.803-809
    • /
    • 2007
  • To those who spend most time within a room, comfortable indoor environment is a very critical element to job performance and health. The comfort technology, which is for enhancing comfort in human living, relates with various factors to ensure human activities efficient, comfortable, safe and satisfactory. Experiments were performed in environmental chamber. Experimental conditions were combinations from three temperatures of 18, 22 and 26C, and two relative humidity levels of 45 and 60%. Air-flow was controlled to 0.1m/s through the experiment. Four male and four female university students participated in the experiments. They had normal blood pressure and their body temperature was under $37^{\circ}C$. From the experiments for evaluating thermal sensation to the air-heating conditions, relationships among TSV, CSV, $SET^*$, PMV were analyzed. Results can be summarized as followings; Thermal neutrality $SET^*$ of man and female was $24.8^{\circ}C$. In air-heating condition, $SET^*$ values for thermal comfort zone were $23.0{\sim}26.5^{\circ}C$. These values were higher than the values from ASHRAE.

Evaluation of the Indoor Thermal Comfort in Consideration of the Solar Radiation (태양 일사를 고려한 실내 열쾌적성 평가 연구)

  • Kim Se-Hyun;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1140-1148
    • /
    • 2004
  • Recently the Predicted Mean Vote (PMV) has been used as an important index to evaluate the degree of the indoor thermal comfort in modern residential buildings. It is known that the PMV is mainly affected by four major factors, which are the air temperature, the air velocity, the humidity and the mean radiant temperature (MRT). Through the numerical calculation of the temperature and the modeling of the mean radiant temperature considering the solar radiation, we proposed the new modeling strategies of the mean radiant temperature and investigated the PMV index and evaluated the MRT. Also, we compared the numerical results with the experimental values. As the results, we found out that the MRT is affected by the wall temperature and the solar radiation. We also knew that the new modeling strategies of the mean radiant temperature is a more correct way of PMV calculation. Especially, the new modeling is necessary for the spaces like an atrium and large rooms with windows mainly influenced by solar radiation.

Evaluation of Thermal Comfort during Sleeping in Summer - Part IV : Study on Indoor Temperature Conditions for Comfort Sleep - (여름철 수면시 온열쾌적감 평가 - 제4보 : 쾌적수면을 위한 실내온도 설정에 관한 연구 -)

  • Kum, Jong-Soo;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.307-312
    • /
    • 2007
  • This study was performed to evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of sleep efficiency and MST under four thermals conditions ($22^{\circ}C,\;24^{\circ}C,\;26^{\circ}C,\;30^{\circ}C$). Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. Their age was from 20 to 22 years old. They were healthy, and had regular sleep with consistent bed and wakeup time. It was checked whether they had a good sleep before the night of experiment. Experiments were performed in an environmental chamber using thermo-hygrostat. The physiological signal (EEG) for sleep stage were obtained from C3-A2 and C4-Al electrode sites. Sleep stages were classified, then SWS latency and SWS/TST were calculated for the evaluation for sleep efficiencies on thermal conditions. As results, mean skin temperature for comfort sleeping was $34.5{\sim}35.4^{\circ}C$. Considering sleep efficiency and mean skin temperature, indoor room temperature of upper limit was $28.1^{\circ}C$.

A Measurement and Evaluation on the Indoor Thermal Conditions in Summer of a New Training ship (신조 운항실습선의 여름철 실내 온열환경 실측평가)

  • Shin, Dong-Keol;Lee, Jin-Uk;Lee, Hyong-Ki;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.276-283
    • /
    • 2008
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those which are supplied and controlled by marine HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured like previous report on a newly-launched training ship during 25th through 27th of July, 2007. Followings are the results of this study. (1)The air supply volumes to each cabins are measured 250CMH(Recreation room), 800CMH(Conference room), 1.000CMH(Bridge), 5,100CMH(Lecture room) respectively. (2)The temperatures are maintained at $21{\sim}27^{\circ}C$ in almost cabins through measuring period, but the temperatures are fluctuated over ${\pm}4^{\circ}C$ at the bridge and conference room. (3)The relative humidities are shown between $40{\sim}60%$ known as comfort conditions, but the conference room is needed to dehumidified because of over 70% humidity. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of temperature diversities, only 32% among the measured data are satisfied with the comfort standard range proposed by ASHREA.

Study on Comfortable Room Temperature using Mean Skin Temperature analysis in Sleeping (평균피부온도 분석을 통한 수면시 쾌적 실내 온도조건에 관한 연구)

  • KIm, Dong-Gyu;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • It is necessary to control the room temperature for comfortable and deep sleep during a tropical night. We need to investigate thermal transport and parameter between human and environment for comfortable sleep. Therefore this study is performed to evaluate the comfortable room temperature based on the change of skin temperature under variations in thermal conditions and several reports. Five female subjects of 20~22 years with similar sleeping pattern were participated for the experiment. The subjects arrived in chamber at 9 pm and adapted to thermal circumstances during 2 hours. The sensors was sticked in body for skin temperatures. If subjects fall asleep in chamber, lights off and then sleep during 8 hours.As results, indoor temperature range for comfort sleep was $23.9{\sim}28.4^{\circ}C$ based on comfort mean skin temperature. But considering transition of time, minimum indoor temperature was $21.6^{\circ}C$, $22.9^{\circ}C$, $24.1^{\circ}C$, $23.9^{\circ}C$ and maximum indoor temperature was $28.2^{\circ}C$, $30.1^{\circ}C$.

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.