• Title/Summary/Keyword: Indoor pollution degree

Search Result 22, Processing Time 0.035 seconds

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

Pproperties of formaldehyde and CO2 adsorption type matrix using TiO2 photocatalysis (광촉매를 활용한 흡착형 경화체의 포름알데히드 및 CO2 특성)

  • Lee, Won-Gyu;Pyeon, Su-Jeong;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.153-154
    • /
    • 2018
  • As the air pollution progresses, the pollution degree of the indoor air quality is increased, and when the pollution degree of the indoor air quality is increased, it causes respiratory diseases and skin diseases. In addition, volatile organic compounds are released from the materials used for architectural interior decoration, and volatile organic compounds are the main cause of polluting indoor air quality. In order to improve indoor air quality, we tried to secure indoor air quality pollution by using photocatalyst which has the function of decomposing harmful substances. photocatalyst is a material that promotes chemical reaction by absorbing light. The photocatalyst used in the experiment was TiO2, In this study, an adsorption type hardener for reducing volatile organic compounds was prepared by photocatalytic reaction. the formaldehyde and CO2 concentrations of the cured products were analyzed according to the TiO2 content.

  • PDF

Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model (실내 공간별 미세먼지농도 비교 데이터의 시각화)

  • Lee, Sangik;Lee, Jin-Kook
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

A Study on Plant Effects on Decontamination of Polluted Indoor Air with Formaldehyde (포름알데히드로 오염된 실내공기의 정화에 미치는 식물효과에 관한 연구)

  • Park, Soyoung;Kim, Jeoung;Jang, Young-Kee;Sung, Kijune
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.147-155
    • /
    • 2005
  • This study was designed to investigate the effect of plant as a botanical air purification on the indoor pollution by formaldehyde. Three indoor plants such as Dracaena marhginata, Spathiphyllum and Dracaena reflexa, were placed in the artificially contaminated reactor under laboratory condition. Both plant and soil effects on removal of formaldehyde from contaminated indoor air were observed. Reductions in the formaldehyde levels appeared to have been associated with soil medium factors as well as plant factors. The effect of soil on formaldehyde reduction was high in the early stage of the experiment and the results suggest that sorption could be more important factor than microbial degradation in the initial dissipation of contaminants in the soil. It was suggested that the effect of plant on formaldehyde reduction might be related to the plant species, total leaf surface area of plant, degree of contribution of soil medium, and exposed concentration level. The results of this study showed that air purification using plants is an effective means of reduction on indoor formaldehyde level, though, utilization of soil media with high sorption capacity and/or supplementary purifying aids were also suggested when the source is continuous or exposed concentration level is high.

The Evaluation and Investigation of Conscious Cognition Degree on a room-size air cleaner (실내용 공기청정기의 성능평가 및 인식도 조사)

  • 손종렬;김영환;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.115-120
    • /
    • 2002
  • This study was performed on a questionnaire survey of 500 people about their awareness for indoor air pollution, and measured efficiency of air cleaner which can remove the CO and air-borne particulate of ETS(Environmental Tobacco Smoke) in air clean chamber. The room-size cleaner for measuring indoor air contaminants has been applied to evaluation of two different air cleaner such as the mechanic air cleaner with hepafilter(HPA) and the electrostatic air cleaner with metal plate. The measuring experiment was carried out in a chamber by sampling the air. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 38% of them can feel indoor air pollutions degrees directly by their sense of smell, For the installation of indoor pollution control equipment, 34% of all respondents installed air cleaner because of the problem of economical charge and almost respondents was not satisfied the trust of ability purified indoor air pollutants. In the experimental results, it was found that more than 95% of CD and air-borne particulate of ETS were removed within 20 minutes. The reaction kinetics of removal pollutants was verified as the pseudo-first order, Finally, it appeared that the room-sire air cleaner can be applied to new technology for removing indoor air contaminants.

Physical Properties of Magnesium Oxide-Based Adsorption Matrix using Diatomite (산화마그네슘 기반 규조토를 활용한 흡착형 경화체의 물리적 특성)

  • Lee, Won-Gyu;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.184-185
    • /
    • 2019
  • Korea has defined fine dust as a social disaster as the problem of fine dust and air pollution becomes serious. Fine dust is classified as class one carcinogens because it is harmful to human body. When fine dusts enter the human body, they cause bronchial and skin diseases such as respiratory allergies, irritable pneumonia, asthma and atopy. As the air pollution becomes serious, the government is demanding measures to reduce fine dust. The polluted air in the outdoor is introduced into the room, thereby increasing the pollution degree of the indoor air quality. In this study, an adsorption type matrix for the improvement of indoor air quality was produced. Magnesium oxide and magnesium chloride were used as binders and diatomaceous earth was used as a adsorption material.

  • PDF

Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment (실내환경중의 산소발생기 사용에 대한 인식도 평가)

  • 손종렬;조윤수;이규현;황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

The satisfaction and subjective symptom level by indoor air quality in dental parlor in Capital and Jeon-nam area (일부지역 치과위생사의 치과진료실 실내공기질에 대한 만족도 및 자각증상 비교)

  • Choi, Mi-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.405-417
    • /
    • 2011
  • Objectives : A precedent research has documented that indoor air pollution is closely associated with increased the risk of symptom and decreased in job satisfaction. This study was conducted in an effort to assess the relationship of indoor air quality to self-perceived symptom and satisfied with working environment. Methods : This research is based on self-filling survey which 393 dental hygienists who work in seoul and Jeon-nam area participated on October 2010 through January 2011. This survey was compared and analyzed about the level of satisfaction and subjective symptom by the indoor air quality that dental office's working environment. Results : The result of satisfaction degree of hospital working environment was pretty low about office air. Most people mentioned that they were sore and dull all over the back, shoulder, and neck. Also, they were drowsy and exhausted in work place. Conclusions : In conclusion, it is need to improve their quality of life and mental health by developing proper air conditioning system and using one in their work place.