• 제목/요약/키워드: Indoor noise condition

검색결과 46건 처리시간 0.027초

Enhanced Spatial Modulation of Indoor Visible Light Communication

  • Shan, Ye;Li, Ming;Jin, Minglu
    • Journal of information and communication convergence engineering
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, we consider visible light communication in an indoor line-of-sight environment. It has been proved that among the multiple input multiple output (MIMO) techniques, spatial modulation (SM) performs better than repetition coding (RC) and spatial multiplexing (SMP). On the basis of a combination of SM and pulse amplitude modulation (PAM), here, we propose an enhanced SM algorithm to improve the bit error rate. Traditional SM activates only one light-emitting diode (LED) at one time, and the proposed enhanced SM activates two LEDs at one time and reduces the intensity levels of PAM by half. Under the condition of a highly correlated channel, power imbalance is used to improve the algorithm performance. The comparison between the two schemes is implemented at the same signal-to-noise ratio. The simulation results illustrate that the enhanced SM outperforms the traditional SM in both highly correlated and lowly correlated channels. Furthermore, the proposed enhanced SM scheme can increase the transmission rate in most cases.

약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례 (Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers)

  • 김제훈;김기연
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.

가전제품 소음등급 기준설정에 관한 연구 (Study on Establishment of the Noise Grade Criteria for Household Appliances)

  • 박형규;이재원;이우석;한진석;구진회
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

친환경건축물 인증제도 평가를 통한 고층 주거용 건물의 환경성능 분석 (A Study on the Analysis of Environment Performances in High-Rise Residential Building Through Green Building Certification System)

  • 채문병;차민철;제성호;석호태
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.281-286
    • /
    • 2006
  • In case of Korea, immovable property like location, land prise or investment value is more highly estimated than quality of life of residents for performance and value of apartment house, because of limited land area or high density of population. But the high level of life has recently caused the increasing demand in better life. As there is no cases to provide the house in bulk due to the housing market condition, it is necessary to evaluate performance and value of structure, disaster prevention safety, habitability, antiquated condition of building and equipment, maintenance condition and so on that has importantly influence on resident's life quality. So, this study aims to understand the actual condition of environmental performance for the present apartment by comparing the designated apartment, which is ready to have completed in Daegu, with the mixed use residential building, which gained the best grade for green building certification system. Also by analyzing and evaluating a right to enjoy sunshine, floor impact noise etc. and indoor air quality.

  • PDF

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

창호지의 흡음성능에 관한 실험적 연구 (Sound Absorption Performance of Korean Traditional Window Papers)

  • 최은석;이태강;김항;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2006
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to he standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound absorption characteristics according to difference in thickness and finishing method of window paper and those in sound absorption characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

전통창호의 차음 특성에 관한 연구 (A study on the Sound Insulation Characteristics of Korean Traditional Windows)

  • 김항;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1147-1150
    • /
    • 2007
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material. Or traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to be standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound insulation characteristics according to difference in thickness and finishing method of window paper and those in sound insulation characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

댐 수차 발전기 소음의 전달특성과 평가에 관한 연구 (A Study on Traveling Characteristics and Evaluation about Noise of Hydraulic Turbine Dynamo in Dam)

  • 윤재현;국정훈;김재수
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.705-711
    • /
    • 2008
  • 국내의 경우 1965년 섬진강댐을 시초로 홍수조절 수력발전 관개 상수 공업용수 공급 등의 역할을 하는 14개의 다목적댐을 건설하였다. 이러한 다목적댐의 경우 물의 낙차와 양에 의한 위치에너지를 운동에너지로 전환하여 전기에너지를 생산하게 된다. 그러나 이 과정에서 수차 발전기에 연결된 터빈의 회전시 고소음을 발생시켜 사람들에게 신체적, 정신적 악영향과 효율적인 업무능률의 저하를 초래한다. 이러한 관점에서 본 연구는 16개의 다양한 측정점을 선정하여 대청댐의 수차 발전기에서 발생하는 소음의 전달특성을 측정 분석하였으며, PSIL, NC 등의 평가지수로 실내소음의 정도를 평가해 보았다. 소음평가 결과 대청댐의 경우 여러 공간에서 소음의 피해 정도는 매우 심각하게 나타나 방음대책이 절실히 필요할 것으로 사료된다. 이러한 자료는 향후 수차 발전소의 효율적인 소음 저감대책과 쾌적한 업무 환경 수립을 위한 유용한 자료로 활용될 수 있을 것으로 사료된다.

도심형 소규모 초등학교의 외부공간 계획방향에 관한 연구 (A Study on the Outdoor Space Design for Urban Mini Schools)

  • 이선영;권민성
    • 교육시설 논문지
    • /
    • 제20권2호
    • /
    • pp.33-42
    • /
    • 2013
  • Due to the lack of available site in urban setting outdoor space in elementary schools are getting smaller and tend to be replaced by indoor spaces. Focusing on courtyard, piloti space and roof space, this study analyzed the current condition and usage of the outdoor spaces in the urban mini-schools based on the analysis of architectural drawing, interview, survey, and observation. Following issues are found for appropriate planning for outdoor spaces in the urban mini-schools. Firstly, roof space needs to be coordinated with the physical education and outdoor class curriculum and should be planned separately for quiet activities. Secondly, the piloti space should be planned as an independent space rather than a connection between classroom and outdoor space, with appropriate surveillance from teacher's space for the lower graders. Thirdly, courtyard space, typical space in urban mini school surrounded by densely arranged buildings, should be thermally controlled for outdoor class or resting with appropriate screen from noise to keep quiet atmosphere.