• Title/Summary/Keyword: Indoor light

Search Result 519, Processing Time 0.037 seconds

Reliability Analysis of Degradation Data for LEDs (LED 열화데이터의 신뢰성 분석)

  • Park, Chang-Kyu
    • Journal of Applied Reliability
    • /
    • v.9 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF

High efficient Transflective TFT-LCD by tRGB-rW Sub-Pixel Rendering

  • Lin, L.;Liang, B.J.;Huang, C.M.;Lin, H.C.;Chen, Y.N.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1613-1617
    • /
    • 2006
  • The total light efficiencies of the novel 1.9" transflective tRGB-t/rW and tRGB-rW TFT LCDs are calculated and they are implemented by the traditional 7-mask ${\alpha}$-Si processing. Then, the two vehicles are turned on with the appropriate Sub-Pixel Rendering White (SPRW) algorithms, so they can exhibit the extra luminance without the original visual resolution loss. Their outstanding optical properties are approved by measuring the contrast ratio (C.R.) and the NTSC ratio. Because they utilize the light resource very effectively and efficiently, they are very suitable for the dark indoor and the bright outdoor environments.

  • PDF

Indoors Thermal Environment by Vertical Temperature Differences in Atrium Space (아트리움형 공간 내 수직온도차에 따른 온열환경)

  • We, Seunghwan;Lee, Jongki;Kim, Sughwan;Kim, Sumin;Chang, Jae D.
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.2
    • /
    • pp.122-128
    • /
    • 2014
  • Recently, many studies have conducted to satisfy a physical need of human between environment of light on space, so an atrium structure has been applied to cultural complex. However, this structure brings about many problems such as overheating in summer, excessive vertical temperature differences, condensation, diffusion of noise, effect of echo, and withering landscapes. Especially, in this research, thermal comfort by difference of vertical temperature in the space of atrium and the optical characteristics of glass skins of the atrium could be remarkably effected by solar flux entering indoors.

  • PDF

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

A Study on the Architectural Design Plans Using BIPV (BIPV를 활용한 건축물 디자인 계획에 관한 연구)

  • Juen, Guen-Sik;Ryu, Soo-Hoon
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.3
    • /
    • pp.5-13
    • /
    • 2012
  • In this study, features and design effects of PV(Photovoltaic) modules were classified to help the installation of BIPV(Building Integrated Photovoltaic) In addition, through domestic and international trends and cases survey, installation method was organized and applicable range of efficiency and design from First-generation solar cells to the third-generation solar cell was classified. Frist, Crystalline Solar cell module of first-generation is appropriate for the wall type, roof, louver, shading and etc. It has superiority of technology and price stability and can be achieved by a variety of aesthetic effects. Second, Dye-Sensitized Solar Cell of Thin Film solar cell can express a variety of colors, adjust light transmittance and maximize the aesthetic splendor. It is appropriate for the wall type, window type, curtain wall type and etc. Also, see-through type solar cell can provide comforts cause of free flow of light. And it is advantageous from economic due to adjust the indoor temperature. It is appropriate for the atrium type, curtain wall type, window type and etc.

Development of the Inorganic Paint Using Blast Furnace Slag$\cdot$Photocatalytic Carrier and the Removal Property of NOx and Indoor a Pollutant (고로슬래그$\cdot$광촉매담체를 이용한 무기도료의 개발과 질소산화물 및 실내오염물질의 제거 특성에 관한 연구)

  • Chai Han sik;Lee Jun-cheol;Kim Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.385-388
    • /
    • 2005
  • In this study, the objective is to develope environment friendship mineral pigments for removal of harmful chemical substance. Environment friendship mineral pigments made of Slag blast furnace-photocatalyst carriers were developed to identify their removal effects of NOx, HCHO and VOCs(benzene, Toluene) on sunlight, fluorescent light and UV lamp. In case of NOx at UV light, the eliminative ability was been better than different harmful materials, and it was appeared large degree rather than different harmful materials.

  • PDF

Energy harvesting from conducted electromagnetic interference of fluorescent light for Internet of Things application

  • Hyoung, Chang-Hee;Hwang, Jung-Hwan
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.759-768
    • /
    • 2022
  • A novel energy harvesting technique that uses conducted electromagnetic interference as an energy source is presented. Conducted EMI generated from fluorescent light using a switched-mode power supply was measured and modeled as an equivalent voltage source. Two types of rectifier circuits-a bridge rectifier and a voltage doubler-were used as the harvesting devices for conducted EMI source. The matching networks were designed based on the equivalent model, and the harvested power was improved. The implemented energy harvester produces a regulated power over 68.9 mW and current over 15.1 mA while a regulated voltage can be selected between 3.3 V and 5 V. The proposed system shows the highest harvesting power indoor environment and can provide enough power for the Internet of Things devices.

Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings (스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이)

  • Jae-Hyang Kim;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

An Efficient Smart Indoor Emotional Lighting Control System based on Android Platform using Biological Signal (생체신호를 이용한 안드로이드 플랫폼 기반의 효율적인 스마트 실내 감성조명 제어 시스템)

  • Yun, Su-Jeong;Hong, Sung-IL;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.199-207
    • /
    • 2016
  • In this paper, we propose efficient smart indoor emotional lighting control system based on android platform using the biological signal. The proposed smart indoor smart emotional lighting control system were configured as the biological signal measurement device and removable smart wall pad, lighting driver, luminaire. The control system was extracts the emotional language by measured the biological signal, and it was transmitted a control signal to each lighting driver using a bluetooth in the wall pad. The lighting driver were designed to control the lighting device through an expansion board by collected control signal and the illuminance information the surrounding. In this case, the wall pad can be selecting of manual control and the bio signal mode by that indoor emotional lighting control algorithms, and it was implemented the control program that possible to partial control by selecting the wanted light. Experiment results of the proposed smart indoor emotional lighting control system, it were possible to the optional control about the luminaire of required area, and the manual control by to adjustable of color temperature with that the efficiently adjustable of lighting by to biological signal and emotional language. Therefore, were possible to effective control for improvement of concentration and business capability of indoor space business conduct by controlling the color and brightness that is appropriate for your situation. And, was reduced power consumption and dimmer voltage, lighting-current than the existing-emotional lighting control system.

Assessment of Exposure to and Risk of Formaldehyde and Particulate Matter (PM10 and PM2.5) by Time Activity Applying Real-Time Indoor and Outdoor Monitoring (실내·외 실시간 모니터링을 활용한 폼알데하이드 및 미세먼지(PM10, PM2.5)의 거주시간별 노출 및 위해도 평가)

  • Yoon, Danki;Namgoung, Sunju;Kong, Hyekwan;Hong, Hyungjin;Lim, Huibeen;Park, Sihyun;Lee, Hyewon;Lee, Jungsub;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.646-657
    • /
    • 2019
  • Objectives: The purpose of this study was to suggest methods to investigate continuous monitoring of concentration levels and assess the exposure of individuals considering the actual time activity of residents for formaldehyde and particulate matter (PM10, PM2.5) in the indoor and outdoor air of a house, assess the health risks of children and adults based on the results of the exposure assessment, and provide basic data on studies for assessing exposure and health risks in Korea in the future. Methods: The concentration levels of formaldehyde and particulate matter were measured in a family home in Gyeonggi-do Province from April 25 to July 31, 2019, using electrochemical sensors (formaldehyde) and light scattering sensors (PM10, PM2.5). Risk assessment by the duration of exposure by time activity was performed by dividing between weekdays and weekends, and indoors and outdoors. Results: The greatest level of carcinogenic risk from inhaling formaldehyde was indoors during the weekdays for both children and adults. For children, the risk was at 7.5 per approximately 10,000 people, and for adults, the risk was at 4.1 per approximately 10,000 people. PM10 and PM2.5 also showed the greatest values indoors during the weekdays, with children at 1.7 people and 1.4 per approximately 100 people, respectively, and adults at 8.2 per approximately 1,000 and 1.8 per approximately 100 people, respectively. Conclusions: The risks of formaldehyde, PM10 and PM2.5 were shown to be high indoors. Therefore, consideration of exposure assesment for each indoor pollutant and management of indoor air quality is necessary.