• Title/Summary/Keyword: Indoor facility

Search Result 227, Processing Time 0.023 seconds

Study on Changes of Street Furniture in Digital Environment (디지털 환경에서 가로시설물의 변화에 관한 연구)

  • In, Chiho;Kim, Hyunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1D
    • /
    • pp.129-136
    • /
    • 2008
  • Along with the development in cutting-edge digital technology, the street space is also being changed. Mobile telecommunication units and internet give a big change in a human being's lifestyle. And the ubiquitous computing is proceeding with expanding its application range from the indoor space to the street space. As the street furniture is the convenient facility that allows a human being's life in street space to be abundant, it is getting advanced. First of all, in terms of such phenomenon, this study analyzed the cases of a research on application of street space and the actual condition of a change in the number of individuals for the street furniture, through a literature research of ubiquitous. Also, it researched into the realities of using the street furniture of the walking-desired streets at Daehac-ro and Hongdae district, where are two representative places related to digital generation. The next was carried out FGI (Focus Group Interview) with users of the street space in front of Hongik University and managers of the street furniture, and was researched into the use & management behavior, and recognition level on the street furniture. Thus, the key elements were extracted such as interchange of information for cultural activities, automation for interaction variability in function. Finally the core elements for future vision of street furniture in this digital era were extracted in 3I, namely, Information, Intellectualization, and Integration. This is considered to be applied to the establishment of direction in the process of high-tech digitalization in street furniture related to information hereafter.

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

Changes in Accommodative Function of Young Adults in their Twenties following Smartphone Use (스마트폰 사용에 따른 20대 성인의 조절기능 변화)

  • Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.

A Case Study on Introducing Vita Parcours as Forest Leisure Sports Facility in Saneum Healing Forest (산음 치유의 숲 Vita Parcours 도입 사례 연구 - Vita Parcours 도입을 사례로 -)

  • Lee, Jin-Kyu;Kim, Ki Weon
    • The Journal of the Korean Institute of Forest Recreation
    • /
    • v.22 no.4
    • /
    • pp.71-81
    • /
    • 2018
  • It is necessary to build a quality-enhancing forest leisure sports facility according to values that value life quality, national forest policy. Vita Parcours (fitness trails) is found to be the activities highly convenient, so their introduction and promotion in Korea should be highly considered. field survey was necessary to explore the possibility of installing Vita Parcours. Several sites were selected, such as Asean recreational forest, Unaksan recreational forest, Yumyeongsan recreational forest, Saneum recreational forest, Jungmisan recreational forest and National center for forest therapy. At these locations, we explored the current status of forest facilities and forest trails. A total number of 31 exercise facilities has been identified and surveyed, some of which are located on the trails (2), alongside the trail (9), alongside trail boundaries (2) or represent facilities suitable for both outdoor and indoor exercise within the forest (18), all of whom provide location for 44 different exercise routines (flexibility exercises (23), endurance (12) and strength exercises (9)). Field work also included identification of forests paths, the total number of whom was 34 paths - 30 identified as trails, 2 as hiking trails, 1 as a forest path for relaxation and healing and 1 as an exploratory path. Regarding the structure and shape of these trails, 32 was straight in shape and only 2 designed as a circular forest trails. Average length of these trails was 652.2m with the highest and the lowest point altitude difference of 60m, on average. Saneum recreational forest provide the most suitable site/environment for Vita Parcours and as a result of this, Saneum recreational forest is proposed as a location to support the endeavors in promotion of these valuable forest fitness trails. Among the forest paths at this site, a forest path which has a length of 1.84km and 73.0m the highest and the lowest point altitude difference was selected as the most suitable, and may be equipped with necessary stations for exercise or obstacles. In addition, if these trails are to be introduced and welcomed by its users, we must assure that they are properly maintained.

A Study of Fluoride Adsorption in Aqueous Solution Using Iron Sludge based Adsorbent at Mine Drainage Treatment Facility (광산배수 정화시설 철 슬러지 기반 흡착제를 활용한 수용액상 불소 흡착에 관한 연구)

  • Lee, Joon Hak;Kim, Sun Joon
    • Economic and Environmental Geology
    • /
    • v.54 no.6
    • /
    • pp.709-716
    • /
    • 2021
  • In this study, an adsorbent prepared by natural drying of iron hydroxide-based sludge collected from settling basin at a mine drainage treatment facility located in Gangneung, Gangwon-do was used to remove fluoride in an artificial fluoride solution and mine drainage, and the adsorption characteristics of the adsorbent were investigated. As a result of analyzing the chemical composition, mineralogical properties, and specific surface area of the adsorbent used in the experiment, iron oxide (Fe2O3) occupies 79.2 wt.% as the main constituent, and a peak related to calcite (CaCO3) in the crystal structure analysis was analyzed. It was also identified that an irregular surface and a specific surface area of 216.78 m2·g-1. In the indoor batch-type experiment, the effect of changes in reaction time, pH, initial fluoride concentration and temperature on the change in adsorption amount was analyzed. The adsorption of fluoride showed an adsorption amount of 3.85 mg·g-1 16 hours after the start of the reaction, and the increase rate of the adsorption amount gradually decreased. Also, as the pH increased, the amount of fluoride adsorption decreased, and in particular, the amount of fluoride adsorption decreased rapidly around pH 5.5, the point of zero charge at which the surface charge of the adsorbent changes. Meanwhile, the results of the isotherm adsorption experiment were applied to the Langmuir and Freundlich isotherm adsorption models to infer the fluoride adsorption mechanism of the used adsorbent. To understand the thermodynamic properties of the adsorbent using the Van't Hoff equation, thermodynamic constants 𝚫H° and 𝚫G° were calculated using the adsorption amount information obtained by increasing the temperature from 25℃ to 65℃ to determine the adsorption characteristics of the adsorbent. Finally, the adsorbent was applied to the mine drainage having a fluoride concentration of about 12.8 mg·L-1, and the fluoride removal rate was about 50%.