• Title/Summary/Keyword: Indoor facility

Search Result 230, Processing Time 0.025 seconds

The Effects of Psychomotorik in the Forest on the Sensory and Visual Perception of Children with Intellectual Disabilities

  • You, Jin-Hee;Shin, Won-Sop
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.3
    • /
    • pp.321-332
    • /
    • 2019
  • The purpose of this study is to investigate the changes of sensory and visual perception of children with intellectual disabilities by conducting psychomotorik (psychomotor activity) in the forest and indoor treatment rooms. Accordingly, this study divided 18 children with intellectual disabilities living in the facility for persons with disabilities located in Seoul into three groups: the experimental group participating in psychomotorik in the forest, the comparative group participating in psychomotorik in the treatment room, and the control group without any treatment at all. The program was conducted for 32 weeks, 4 hours a month. The results showed that psychomotorik promoted the sensory and visual development of children with disabilities. Psychomotorik in the forest showed significant effects on touch and activity level, form constancy and eye-hand coordination. Psychomotorik in the treatment room showed significant improvement in figure-ground with reduced motion. This suggests that psychomotorik in the forest as well as indoors is a positive factor for sensory adaptation reaction and visual development of children with intellectual disabilities.

A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation (건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구)

  • Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

An Analysis of the Current Status and Characteristics of Airborne Fungi in Indoor Air in Multi-Use Facilities Nationwide (전국 다중이용시설의 실내공기 부유 곰팡이의 현황 및 특성 분석)

  • Park, Yongsung;Kwon, Soonhyun;Park, Song-Yi;Kee, Sun-Ho;Yoon, Wonsuck
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.5
    • /
    • pp.282-289
    • /
    • 2022
  • Background: Airborne fungi are ubiquitous in the air and exposure to an airborne fungus can be a significant risk factor. The composition of fungi has been potentially important for human health, especially for respiratory diseases like asthma and atopic dermatitis. Therefore, we attempted to ascertain what kind of airborne fungi affect human health at a nationwide level. Objectives: This study was carried out to provide information on indoor fungi distribution at multi-use facilities throughout South Korea. Methods: We classified our data by region and public facility after collection, cultivation, and identification via the sequencing of the ITS (internal transcribed spacer) region. We investigated whether or not the proliferation of HaCaT cells was affected by the identified airborne fungi. Results: In our data, the most isolated airborne fungi by region were Penicillium spp (Seoul, Daegu), Periconia sp (Gyeonggi-do), Iprex sp (Gangwon-do), Phanerochaete sp (Busan), Bjerkandera sp (Gwangju), and Aspergillus sp (Jeju-do). In the public facilities, the most detected fungi were Cladosporium sp (public transport), Penicillium sp (apartment house, retail market, financial institution, karaoke room), Bjerokandera sp (underground parking lot, public toilet, medical institution), Periconia sp (retail store), and Fusarium sp (general restaurant). Next, we selected twenty airborne fungi to examine their cytotoxicity and proliferation of human skin cells. In this experiment, the proliferation of the cells was influenced by most of the identified fungi. In case of the cytotoxicity test, most genera except for Rhodotorula sp and Moesziomyces sp showed cytotoxicity in HaCaT cells. Conclusions: The distribution of mold in the indoor air in multi-use facilities in South Korea differs from region to region, and this is an indicator that should be considered in future health impact studies. In addition, as a result of culturing about 20 types of bacteria dominant in indoor air, it was found that most (90%) inhibit the growth of skin cells, which can be harmful to health. An in-depth study of the health effects of floating fungi is needed.

Field Study of Characteristics of Airborne Bacteria Distributed in the Regulated Public Facilities (규제대상 다중이용시설내 부유세균의 분포 특성에 관한 현장 조사)

  • Kim, Ki Youn;Jang, Gyu Yeob;Park, Jae Beom;Kim, Chi-Nyon;Lee, Kyung Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Concentration and identification of airborne bacteria in the regulated public facilities were examined with the six-stage cascade impactor. Geometric mean total and respirable concentrations of airborne bacteria were $404cfu/m^3$ and $194cfu/m^3$ in hospital, $931cfu/m^3$ and $358cfu/m^3$ in kindergarten, $294cfu/m^3$ and $134cfu/m^3$ in day-care center, and $586cfu/m^3$ and $254cfu/m^3$ in postpartum nurse center, respectively. As a result, culturable total and respirable concentrations of airborne bacteria were significantly highest in kindergarten and lowest in day-care center (p<0.05). The ratio of respirable to total concentration of airborne bacteria in the investigated public facilities was ranged from 30% to 40% but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.58 and 0.66 in hospital, 0.71 and 0.83 in kindergarten, 0.28 and 0.41 in day-care center, and 0.63 and 0.78 in postpartum nurse center, respectively. Day-care center showed the lowest I/O ratio of culturable total and respirable concentration of airborne bacteria (p<0.05) but a significant difference was not found among other facilities. Indoor concentration of airborne bacteria did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ and surrounding condition (p<0.05). Staphylococcus spp., Micrococcus spp., Corynebacterium spp., and Bacillus spp. were dominant genera and amounted to over 95% of total airborne bacteria identified in the investigated public facilities. Size distributions of four dominant genera did not observed inconsistently regardless of type of public facility.

A Study of Color Scheme on Coastal Passenger Ship Seafarer's Workspace (연안여객선 선원의 작업공간 색채계획에 관한 연구)

  • Jin Park
    • Journal of Navigation and Port Research
    • /
    • v.48 no.3
    • /
    • pp.221-231
    • /
    • 2024
  • The aim of this study was to enhance the safety and care of mental health for seafarer working in passenger ship workspaces. Brightness, color values, and color distribution were investigated with issues and improvement ways identified through seafarers' interviews. Firstly, previous studies, references, current policy, regulations, and accident case studies were reviewed. Color compositions of wheelhouse and engine room of M Ship were then surveyed in the field. Color values of each space were analyzed using a colorimeter. Colormeter analysis of brightness and color measurements in the wheelhouse and engine areas indicated that ceilings, walls, and floors were generally dark, with the engine area being very dark. Regarding color, green and blue were distributed in the ceiling of the wheelhouse and engine area, while red and blue were in the walls and floors of the wheelhouse and engine area. According to interviews with seafarers currently working at engine rooms, they responded about their experience of near miss incidents due to a decrepit indoor environment, a dark working environment, slippery and bright flooring, and stairs that were not suitable for domestic users. Thus, when installing lighting in the future, the brightness of the space should be improved by distinguishing between night and day. A lighting plan considering the location of lighting, level of shadow formation and contrast, reflectance of the facility, glare, color of light, floor color plan, and material selection is needed. A facility design suitable for domestic users is also needed.

Size Distribution and Concentration of Airborne Fungi in the Public Facilities (다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성)

  • Park, Jae-Beom;Kim, Ki-Youn;Jang, Gyu-Yeob;Kim, Chin-Yon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.36-45
    • /
    • 2006
  • The aim of this study is to examine size-based concentration and genera of airborne fungi distributed in public facilities such as hospital, kindergarten, day-care center and postpartum nurse center and to provide fundamental data in order to prevent respiratory diseases caused by exposure to airborne fungi. Culturable total and respirable concentrations of airborne fungi averaged to $382\;cfu/m^3\;and\;292\;cfu/m^3$ in hospital, $536\;cfu/m^3\;and\;347\;cfu/m^3$ in kindergarten, $334\;cfu/m^3\;and\;266\;cfu/m^3$ in day-care center, and $371\;cfu/m^3\;and\;289\;cfu/m^3$ in postpartum nurse center, respectively. The ratio of respirable to total concentration of airborne fungi in the investigated public facilities was ranged from $55\%\;to\;70\%$ but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.56 and 0.64 in hospital, 0.72 and 0.91 in kindergarten, 0.33 and 0.45 in day-care center, and 0.63 and 0.73 in postpartum nurse center, respectively. Indoor concentration of airborne fungi did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ concentration (p<0.01) and surrounding condition (p<0.05). Penicillium spp., Cladosporium spp., and Aspergillus spp. were estimated to over $95\%$ of total airborne fungi identified in the investigated public facilities.

A Study on Public Needs for Privately Owned Public Space (실내공적공간의 공공성에 관한 연구)

  • Yun, Ji-Hye;Kim, Jung-Gon
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.157-166
    • /
    • 2006
  • Recently, it appears several counterproposals about desirable figures of urban architecture. All of them proposes 'publicity' with cohernt tendency. The reason why it concentrates quantitative expansion of city without united design by urban plannar is that neglect quality values of city. As a solution of poor environment, there cue out the various efforts, about problem of each building, problem of city space, problem of laws and so forth. The reason why necessity of public space was embossed in that architecture extend the activity of citizen and make up the city space. But, each building pursues the private interest, so it is difficult to secure a public space with a high hand. Thus, architecture law has been revised in 1991 and bring the system of open space to match up the publicity and the private interest. Actually, western country brought it and obtained excellent results. While quantity of open space have increased since 1991, a lot of problems revealed in real usage and quality. By means of problem's solution, this study focus on the diversion of recognition for necessity of various open space. In result, on the occasion of approach and openess, except for several building, most glass a facade and the pedestrian can approach easily. Moreover, office buildings near the subway station connected with their low floor. So, the office buildings give openess to pedestrian and a people can approach easily to the buildings. On the occasion of amenity, most have bank and lobby on the first floor and have facilities on the underground floor. It leave open. But the reason why they have bank and lobby is that the space is dry and boring(without elements of nature and rest space). Hence, to make a space full of vitality, it have to plan various design elements and facilities. First of all, plan of indoor public space have to make up facility for the public interest. This study is basic investigation for necessity of indoor public space and through the survey of office buildings, it analyze the character of plan and find out the method of publicity's realization.

Indoor Location-based Emergency Call Service System for Ships using VLC Technology (가시광통신을 이용한 선박 내 위치 기반 응급호출 시스템)

  • Hong, Seung-Beom;Lee, Kyou-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2836-2843
    • /
    • 2015
  • Due to metallicity of materials, a vessel has a limitation to adopt RF-based wireless communication technologies for the inner communication means. Visible Light Communication(VLC) can be a sound alternative to dissolve such a limitation. Using a visual light as a transmission medium, VLC is free from radio interferences and restriction of radio usages which are typically related to RF-based wireless communications. In addition, VLC can not only require the facility cost relatively low because of being possibly converged with existing LED illumination, but also be harmless to the human body. This paper proposes an indoor location-based emergency call service system solution for ships using the VLC technology that supports 256Kbps data rate and 5m transmission distance. This paper presents real implementation and testing results of the solution which verifies the propriety of the proposal.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

The Study on the Derivation of Performance Guidelines for Indoor·Outdoor Temporary Housing Facility (실내·외 임시주거시설의 성능 가이드라인 도출에 관한 연구)

  • Ju, Jaeseong;Park, Jiyong;Gwak, Donghwa;Park, Mijin
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.271-279
    • /
    • 2018
  • Purpose: This study is designed to develop performance guidelines for temporary residential facilities inside and outside the building to improve the residential habit of the victims caused by a disaster. Method: Performance items were set up by analyzing the disaster response system and prior study for eliciting performance guidelines and conducting field surveys of temporary housing facilities and interviews of temporary residential facilities for eliciting relevant performance guidelines. Results: The performance of temporary housing facilities in and out of the country was largely classified as technical, environmental and social, and each presented performance guidelines. The derived performance guidelines were generally similar, although some were similar due to indoor/outdoor characteristics. Conclusion: The performance guidelines presented in this study to improve the residential habit of the victims are applied in practice, and continuous improvement through feedback of results is required.