• Title/Summary/Keyword: Indoor environmental

Search Result 1,569, Processing Time 0.026 seconds

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.

The Space Use in the Initial Period of Namsan Park - Focus on the Newspaper Articles from 1883 to 1917 - (남산공원 태동기의 공간별 활용 유형 - 1883~1917년까지 신문기사를 중심으로 -)

  • Seo, Young-Ai;Son, Yong-Hoon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • As a symbolic landscape of Seoul, Namsan has undergone not only physical changes but also changes in its human use and characteristics. At this point, research on Namsan, which holds diverse stories that have accumulated over a long period, as a cultural landscape is necessary. In particular, a concrete understanding of the characteristics of the mountain's use in the period of its initiation as a modern park is an important task in research on the history of urban parks. Consequently, the purpose of the present study lies in grasping the use of Namsan at the time of the establishment of Kyongsungbu Namsan Park Design Proposal in 1917 and examining the characteristics per space. The research process was based on the status of the park design plan. The primary source of information came from the analysis of historical newspaper articles. Additional materials including documents, old maps, photographs, postcard materials were also used. The period of the study was 1883 to 1917. This time was the initial period of Namsan Park soon after the opening up of Korea's ports to the world. The major spaces in which Namsan was used as a park encompassed Hanyang Park, Waeseongdae Park, Noin-jeong, Jangchung-dan, and remaining parts of Namsan in a natural state. When the main ways in which each space is used are examined based on the data analyzed, Namsan has been used for purposes including public events, accidents, religious worship, track and field days, field trips, and strolls. When the nature of each of the spaces is determined in terms of the characteristics of their use, these spaces were characterized as community parks, outdoor community spaces, indoor community spaces, sports arenas, and natural parks, among other things. The present study is significant in terms of research on the history of parks for confirming that Namsan in the initial period already served as a modern park for urban activities and grasping the specific urban activities that were engaged in on Namsan.

Development of A Three-Variable Canopy Photosynthetic Rate Model of Romaine Lettuce (Lactuca sativa L.) Grown in Plant Factory Modules Using Light Intensity, Temperature, and Growth Stage (광도, 온도, 생육 시기에 따른 식물공장 모듈 재배 로메인 상추의 3 변수 군락 광합성 모델 개발)

  • Jung, Dae Ho;Yoon, Hyo In;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.268-275
    • /
    • 2017
  • The photosynthetic rates of crops depend on growth environment factors, such as light intensity and temperature, and their photosynthetic efficiencies vary with growth stage. The objective of this study was to compare two different models expressing canopy photosynthetic rates of romaine lettuce (Lactuca sativa L., cv. Asia Heuk romaine) using three variables of light intensity, temperature, and growth stage. The canopy photosynthetic rates of the plants were measured 4, 7, 14, 21, and 28 days after transplanting at closed acrylic chambers ($1.0{\times}0.8{\times}0.5m$) using light-emitting diodes, in which indoor temperature and light intensity were designed to change from 19 to $28^{\circ}C$ and 50 to $500{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. At an initial $CO_2$ concentration of $2,000{\mu}mol{\cdot}mol^{-1}$, the canopy photosynthetic rate began to be calculated with $CO_2$ decrement over time. A simple multiplication model expressed by simply multiplying three single-variable models and a modified rectangular hyperbola model were compared. The modified rectangular hyperbola model additionally included photochemical efficiency, carboxylation conductance, and dark respiration which vary with temperature and growth stage. In validation, $R^2$ value was 0.849 in the simple multiplication model, while it increased to 0.861 in the modified rectangular hyperbola model. It was found that the modified rectangular hyperbola model was more suitable than the simple multiplication model in expressing the canopy photosynthetic rates affected by environmental factors (light Intensity and temperature) and growth factor (growth stage) in plant factory modules.

A Study on Risk Factors of Recurrent Otitis Media (소아 재발성 중이염의 위험인자에 대한 연구)

  • Kim, Eun Jin;Kwon, Young Ran;Song, Kang Hoon;Jang, Won Nyung;Lee, Jin;Chang, Jin Keun;Cha, Sung Ho
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2010
  • Purpose : Recurrent otitis media (ROM) is usually defined as ${\geq}$3 distinct and well-documented episodes within 6 months or ${\geq}$4 episodes within 12 months. ROM is sufficiently important to warrant consideration of chemoprophylaxis, tympanostomy tube placement. There also is evidence that children with ROM are at risk for both hearing loss and speech delay. However, studies of ROM have been notably insufficient. In addition, even though environmental, racial, and sociocultural differences can affect risk factors, few studies have been conducted with regard to recurrent otitis media in Korea. Methods : This study was conducted from July 2009 to January 2010 with infants and children who were younger than 60 months old, who visited the out-patient clinics at Han-Il General Hospital and Kyunghee University Hospital. Data were collected by interview using a pre-formed sheet. Among a total of 892 infants and children, 457 were excluded, and the remaining 435 were allocated to 104 with ROM and 331 as a control group. Results : Attendance at daycare centers (P<0.001, OR=2.85), allergic rhinitis (P=0.026, OR=2.32), past history of bronchiolitis (P=0.003, OR=2.33), and low socioeconomic status (P=0.005, OR=2.00) were found to have a close significant correlation with ROM. Risk factors such as sex, having a sibling, breast-feeding, use of pacifiers, atopy, pneumococcal vaccination, influenza vaccination, smoking of parents, and indoor smoking are not relevant. Conclusion : Attendance at daycare centers, allergic rhinitis, past history of bronchiolitis, and low socioeconomic status have been identified as risk factors for ROM.

Anti-oxidative and protective effects of Arthrospira platensis ethanol extracts on zebrafish ROS Induced by UVB Induction (UVB 로부터 ROS를 유도한 제브라피쉬에 스피룰리나 에탄올 추출물의 항산화 및 보호효과에 관한 연구)

  • Jang, Deok-Young;Han, Young-Seok;Yang, Jae-Chan;Kim, Bo-Ae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.423-432
    • /
    • 2018
  • Arthrospira platensis is one of the oldest algae in the world and has been reported to have anti-aging properties, including phycocyanin, tocopherol and beta-carotene. In this study, we tried to search protective activities against UVB-induced reactive oxygen species(ROS) of Arthrospira platensis under indoor cultivation ethanol extracts(ICAE) and outdoor cultivation ethanol extracts(OCAE). The anti-oxidative capacities were evaluated by DPPH radical scavenging activity and SOD-like activities at various concentrations(0.1, 0.5, $1mg/m{\ell}$) of ICAE and OCAE. Zebrafish embryos and HaCaT cells were exposed to UVB radiation and treated with various concentrations(0, 0.01, 0.05, 0.1, 0.5, $1mg/m{\ell}$) of ICAE and OCAE. ROS levels of zebrafish and HaCaT cells were generated by UVB radiation. ROS levels were detected using a fluorescent microscope after DCFH-DA staining. The DPPH radical scavenging activity of ascorbic acid was 73% and SOD-like activity was 86% in the positive control group. ICAE and OCAE at $1mg/m{\ell}$ concentration showed 43, 57% DPPH radical scavenging activity and 20, 19% SOD-like activity. Anti-oxidative of ICAE and OCAE had lower effects than the positive control ascorbic acid but significant results. ROS of UVB-induced zebrafish embryos and HaCaT cells were higher than negative control. ICAE and OCAE treated group decreased ROS concentration dependently than UVB-induced positive control group. These results suggest that Arthrospira platensis ethanol extract may have usability value as a cosmetic material for skin protection.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Effects of Temperature and Irrigation Intervals on Photosynthesis, Growth and Growth Analysis of Pot-grown Cucumber Seedlings (온도와 관수 주기가 오이 포트 묘의 광합성, 생육 및 생장 해석에 미치는 영향)

  • Jin Hee An;Eun Yong Choi;Yong Beom Lee;Ki Young Choi
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.148-156
    • /
    • 2023
  • This study was conducted in an indoor cultivation room and chamber where environmental control is possible to investigate the effect of temperature and irrigation interval on photosynthesis, growth and growth analysis of potted seedling cucumber. The light intensity (70 W·m-2) and humidity (65%) were set to be the same. The experimental treatments were six combinations of three different temperatures, 15/10℃, 25/20℃, and 35/25℃, and two irrigation intervals, 100 mL per day (S) and 200 mL every 2 days (L). The treatments were named 15S, 15L, 25S, 25L, 35S, and 35L. Seedlings at 0.5 cm in height were planted in pots (volume:1 L) filled with sandy loam and treated for 21 days. Photosynthesis, transpiration rate and stomatal conductance at 14 days after treatment were highest in 25S. These were higher in S treatments with a shorter irrigation interval than L treatments. Total amount of irrigation water was supplied evenly at 2 L, but the soil moisture content was highest at 15S and lowest at 25S > 15L > 25L, 35S and 35L in that order. Humidity showed a similar trend at 15/10℃ (61.1%) and 25/20℃ (67.2%), but it was as high at 35/25℃ (80.5%). Cucumber growth (plant height, leaf length, leaf width, chlorophyll content, leaf area, fresh weight and dry weight) on day 21 was the highest in 25S. Growth parameters were higher in S with shorter irrigation intervals. Yellow symptom of leaf was occurred in 89.9% at 35S and 35L, where the temperature was high. Relative growth rate (RGR) and specific leaf weight (SLA) were high at 25/20℃ (25S, 25L), RGR tended to be high in the S treatment, and SLA in the L treatment. Water use efficiency (WUE) was high in the order of 25S, 25L > 15S > 15L, 35S, and 35L. As a result of the above, the growth and WUE were high at the temperature of 25/20℃.

End-use Analysis of Household Water by Metering (가정용수의 용도별 사용 원단위 분석)

  • Kim, Hwa Soo;Lee, Doo Jin;Kim, Ju Whan;Jung, Kwan Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.595-601
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of various kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, miscellaneous. Flow meters are installed in 140 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, miscellaneous. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from 150 lpcd to 169 lpcd for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet (38.5 lpcd) is the first, and the second is laundry water (30.8 lpcd), the third is kitchen (28.4 lpcd), the fourth is bathtub (24.7 lpcd), the next is washbowl (15.4 lpcd). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.