제재업의 생물학적인자 노출실태 평가 (Exposure Assessment for Airborne Biological Agents in Sawmills)

  • 박해동;박현희;이인섭
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.274-281
    • /
    • 2010
  • The objectives of this study are (a) to investigate the distribution patterns and exposure concentrations of biological agents in sawmill industries and (b) to compare sampling methods of biological agents. The representative processes of 5 sawmills were selected to measure total airborne bacteria, fungi, endotoxin as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage impactor and gelatin filteration methods. Endotoxin was collected with polycarbonate filters and analysed by kinetic chromogenic Limulus Amebocyte Lysate method. Geometric mean levels of airborne bacteria, fungi, endotoxin and dust were 1,864 CFU/$m^3$, 2,252 CFU/$m^3$, 31.5 EU/$m^3$ and 2.4 mg/$m^3$. The ratios of indoor/outdoor concentrations were 3.7 for bacteria, 4.1 for fungi, 3.3 for endotoxin and 9.7 for dust. The respiratory fractions of bacteria were 68.0, 50.9, 49.2 and 45.1% in band-saw, table-saw, rip-saw process and outdoor air. The respiratory fractions of fungi were 78.7, 90.8, 87.5 and 84.8% in band-saw, table-saw, rip-saw process and outdoor air, respectively. There was no significant differences in bacterial concentrations among single stage, six stage impaction and filteration methods. But, fungal concentrations measured with filtration methods were significantly higher than those with impaction methods. Geometric mean levels of airborne bacteria and fungi were higher than the OSHA guideline values of 1,000 CFU/$m^3$. The respiratory fractions of fungi were above 75%. The concentrations of biological agents were significantly different among culture-based sampling methods. In the exposure assessments of biological agents, further studies are needed for the comparisons of diverse sampling methods and the investigations of environmental factors.

GC-PDECD를 이용한 공기 중 포름알데하이드의 분석 (Determination of Airborne Formaldehyde Using the Gas Chromatograph-Pulsed Discharge Electron Capture Detector)

  • 김희갑;박미진;김만구
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.117-123
    • /
    • 2002
  • A gas chromatographic method for the determination of airborne formaldehyde was established. In order to be highly detectable with the electron capture detector, formaldehyde was derivatized to its pentafluorobenzyl oxime form by reacting with O- (2,3,4,5,6- pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) at pH of 4.6 and temperature of 50$^{\circ}C$ for 1 hour. Air samples were collected into a Tedlar$\^$(R)/ bag followed by transferring into water contained in two impingers in series. Collection efficiency in the front trap was higher than 90%. Measurement of selected indoor and outdoor air samples showed higher formaldehyde concentrations in indoor air environments and the importance of ventilation for reducing indoor pollution.

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

노출 시나리오를 이용한 대학생들의 유해 공기오염물질 노출 추정 (Estimating Personal Exposures to Air Pollutants in University Students Using Exposure Scenario)

  • 김순신;홍가연;김동건;김성삼;양원호
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.47-57
    • /
    • 2013
  • Studies evaluating the health effects of hazardous air pollutants assume that people's exposure to typical pollutant level is the same as specific regional pollutant level. However, depending on social and demographic factors, time-activity pattern of people can vary widely. Since most people live in indoor environments over 88% of the day, evaluating exposure to hazardous air pollutants is hard to characterize. Objective of this study was to estimate the exposure levels of university students of $NO_2$, VOCs(BTEX) and $PM_{10}$ using the scenarios with time-activity pattern and indoor concentrations. Using data from time-use survey of National Statistical Office in 2009, we investigated time-activity pattern of university students and hourly major action. A total of 1,057 university students on weekday and 640 on weekend spent their times at indoor house 13.04 hr(54.32%), other indoors 7.70 hr(32.06%), and transportation 2.36 hr(9.83%). Indoor environments in which university students spent their times were mainly house and school. Air pollutants concentrations of other indoor environments except house and school such as bar, internet cafe and billiard hall were higher than outdoors, indicating that indoor to outdoor ratios were above 1. According to three types of exposure scenarios, exposure to air pollutants could be reduced by going home after school.

실내.외 공기 중 부유먼지 측정방법 상호간의 비교평가 - 중량법을 대상으로 (Comparative Evaluation of Gravimetric Measurement Methods for Suspended Particles in Indoor and Outdoor Air)

  • 백성옥;박지혜;서영교
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.285-295
    • /
    • 2002
  • In this study, several types of gravimetric methods (such as high, medium, low, and ultra low volume sampling methods) were applied to determine suspended particulate matter concentrations in both ambient and indoor environments. Comparative evaluations were undertaken with SPM data obtained using a variety of samplers (TSP, PM10, and PM4.0) at different sampling flow rates. Correlation coefficients between TSP and PM10 concentrations measured at different flow rates fell in the range of 0.73∼0.94 (n=40). In addition, correlation coefficients for PM concentrations measured by different TSP samplers were in the range of 0.90∼0.95 (n=36 or n=38), while 0.77∼0.91 (n=38) for PM10 samplers. Correlation analysis was also conducted on indoor monitoring data that were measured using ultra-low-volume samplers at both different or identical flow rates. The correlation coefficients were in the range of 0.98∼0.99 (n=38) between TSP and TSP and 0.92∼0.94 (n=38) between TSP and PM10. The mean ratio for high volume PM10 to TSP concentration that was monitored at identical flow rates in the ambient air appeared to be 0.72. The mean ratios of PM10 to TSP and PM4.0 to TSP observed with identical flow rates at indoor environments were 0.47 and 0.40. The results of this study may provide empirical information concerning the compatability of aerosol data obtained by gravimetric sampling methods at different flow rates.

Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea

  • Hwang, Sung-Ho;Yoo, Kyong-Nam;Park, Ji-Ho;Park, Dong-Uk;Yoon, Chung-Sik
    • 한국환경보건학회지
    • /
    • 제35권5호
    • /
    • pp.355-361
    • /
    • 2009
  • This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) $cfu/m^3$, 24 (4.1) $cfu/m^3$, respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) $cfu/m^3$) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) $cfu/m^3$, (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) $cfu/m^3$, 217 (2.2) $cfu/m^3$, 176 (2.4) $cfu/m^3$, respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.

공단지역 주민에서 휘발성 유기오염물질의 호흡기 노출에 대한 생체지표 평가 (Exposure Assessment of volatile Organic Matters (VOCs) Using Exposure Biomarker in the Residents Living Near Petrochemical Industry Areas)

  • 신동천;박성은;임영욱;양지연;김명수
    • Environmental Analysis Health and Toxicology
    • /
    • 제15권3호
    • /
    • pp.81-91
    • /
    • 2000
  • Residents who live near petrochemical industrial areas are exposed to a variety of petrochemicals, including benzene or benzene-containing liquids. It is a serious concern because some VOCs are carcinogens naturally present in petroleum and gasoline. The aim of this study was to assess the exposure to VOCs, measured by personal/indoor/outdoor air sampling, and to estimate the relationship between the air samples and biological monitoring data. Through biological monitoring, we investigated VOCs in blood and s-phenylmercapturic acid (s-PMA) , minor urinary metabolites of benzene. The external benzene exposure of subjects was measured using passive dosimeters and urinary s-PMA and blood-benzene were determined by GC/MS. More than 80% of subjects were detected for m-xylene, ethylbenzene, and toluene in blood samples and not detected at all for chloroform, 1 , 1 , 1 -trichloroethylene, and tetrachloroethylene. The mean concentration of benzene in the breathing zone of residents was 6.3 $\mu\textrm{g}$/m$^3$, personal, indoor and outdoor concentrations were strongly correlated to each other. s-PMA detected in all subject samples was affected by personal exposure (p< 0.05) and the level was different by age (p< 0.01). Blood benzene was not affected by external benzene during these periods .

  • PDF

환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토 (The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment)

  • 최석용;김상희;이정재
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

서울.경기 일부지역 다중이용시설실내공기 중 미세먼지와 미세먼지 중 내독소의 농도 (Indoor Air Concentration of Particulate Matter and Endotoxin in Public Facilities)

  • 전병학;황유경;김형아;이세훈;안규동;허용
    • 한국산업보건학회지
    • /
    • 제18권4호
    • /
    • pp.262-270
    • /
    • 2008
  • This study was conducted to measure concentrations of particulate matter ($PM_{10}$, $PM_{2.5}$) and endotoxin in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child-care facilities, 4 subway stations and 4 bus terminals) from September 2004 to February 2007 in Seoul and Gyeonggi-do province. $PM_{10}$ or $PM_{2.5}$ was measured with glass fiber filter and mini volume air sampler for 6 to 8 hours in indoor and outdoor of the facilities and expressed as ${\mu}g/m^3$. After weighing the filter, endotoxin was analyzed by Limulus Ameobocyte Lysate method ($EU/m^3$). $PM_{10}$ in indoor air was higher (GM and GSD was 78.00 and $1.92\;{\mu}g/m^3$, respectively) than the outdoor air (GM and GSD was 60.70 and $2.23\;{\mu}g/m^3$, respectively, I/O=1.28). All measurements was not exceeded the national maintenance standard. Elderly-care and child-care facilities showed relatively higher concentrations ($83.27\;{\mu}g/m^3$ and $81.75\;{\mu}g/m^3$; I/O=2.01 and 1.19, respectively) than hypermarkets or university hospitals. The highest PM2.5 was seen in child-care facilities ($62.15\;{\mu}g/m^3$, I/O=2.42). The I/O of the endotoxin in the PM10 and the $PM_{2.5}$ was exceeded 1.0 (1.37 and 1.57, respectively). Indoor $PM_{10}$ was affected by user/day and humidity, and endotoxin in the PM10 was affected by temperature. In conclusion, elderly- and child-care facilities are high priority facilities to be improved indoor air quality.

대학 캠퍼스 주변 호프집, PC방, 당구장의 실내 PM2.5 농도를 통한 ETS 노출 수준 평가 (Evaluation of Indoor ETS Exposure Levels in Pubs, PC Game Rooms, and Billiards Halls around a University Campus using PM2.5 Concentrations)

  • 이재환;박동욱;하권철
    • 한국산업보건학회지
    • /
    • 제26권4호
    • /
    • pp.411-417
    • /
    • 2016
  • Objectives: The aims of this study were to determine the indoor level of environmental tobacco smoke (ETS) and to assess the implementation rate of smoke-free laws at hospitality venues around a university campus by measuring particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) as an indicator of ETS. Materials and Methods: We measured indoor $PM_{2.5}$ concentrations at 20 PC game rooms, 20 pubs, and 20 billiards halls using Sidepak AM510, a direct reading portable real time monitor, from October to December 2015. Results: Smoking was observed in 65% of the PC game rooms, 10% of pubs, and 85% of billiards halls. The average $PM_{2.5}$ concentrations were $98.2{\mu}g/m^3$, $29.0{\mu}g/m^3$, and $134.2{\mu}g/m^3$ at PC game rooms, pubs, and billiards halls, respectively. $PM_{2.5}$ concentrations in PC game rooms and billiards halls were 2 to 2.7 times higher than the 24-hour exposure standard for outdoor $PM_{2.5}$ ($50{\mu}g/m^3$) by the Ministry of Environment. Conclusions: Although a smoking ban has been implemented for PC rooms and pubs, smoking is still taking place in many of these places. More stringent legal action is required for successfully protecting patrons and workers from secondhand smoke exposure. A ban on smoking in billiards halls should be introduced as quickly as possible.