Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea

  • Hwang, Sung-Ho (Graduate School of Public Health and Institute of Health and Environment, Seoul National University) ;
  • Yoo, Kyong-Nam (Graduate School of Public Health and Institute of Health and Environment, Seoul National University) ;
  • Park, Ji-Ho (Department of Environmental Health, Korea National Open University) ;
  • Park, Dong-Uk (Department of Environmental Health, Korea National Open University) ;
  • Yoon, Chung-Sik (Graduate School of Public Health and Institute of Health and Environment, Seoul National University)
  • 투고 : 2009.08.26
  • 심사 : 2009.10.01
  • 발행 : 2009.10.31

초록

This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) $cfu/m^3$, 24 (4.1) $cfu/m^3$, respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) $cfu/m^3$) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) $cfu/m^3$, (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) $cfu/m^3$, 217 (2.2) $cfu/m^3$, 176 (2.4) $cfu/m^3$, respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.

키워드

참고문헌

  1. Xiang, L., Zhiqiang, J. Z. : Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling. Building and Environment, 44, 1135-1143, 2009 https://doi.org/10.1016/j.buildenv.2008.08.004
  2. American Conference of Governmental Industrial Hygienists (ACGIH) : Guidelines for the assessment of bioaerosols in the indoor environment. Cincinnati, Ohio, 1989
  3. World Health Organization. Indoor air quality. :biological contaminants. WHO regional publications, European series no, 31, Copenhagen, 1999
  4. Douwes, J., Thorne, P., Pearce, N., Heederik, D. :Bioaerosol health effects and exposure assessment progress and prospects. Annals of Occupational Hygiene, 47, 187-200, 2003 https://doi.org/10.1093/annhyg/meg032
  5. Owen, M. K., Ensor, D. S., Sparks, L. E. : Airborne particle sizes and sources found in indoor air. Atmospheric Environment, 26(A), 2149-2162, 1992 https://doi.org/10.1016/0960-1686(92)90403-8
  6. Kim, K. Y., Jeong, Y. I., Kim, C. N., Won, J. U.,Roh, J. H. : Distribution of airborne microorganism in the feedstuff manufacture factory. Korean Society of Occupational and Environmental Hygiene, 17(4), 335-342, 2007
  7. Fisher, G., Muller, T., Schwalbe, R., Ostrowski, R.,Dott, W. : Exposure to airborne fungi, MVOC and mycotoxins in biowaste-handling facilities. International Journal of Hygiene and Environmental Health, 203, 97-104, 2000 https://doi.org/10.1078/S1438-4639(04)70014-0
  8. Burge H. Bioareosols : prevalence and health effects in the indoor environment. Journal of Allergy Clinical Immunology, 86, 687-701, 1990 https://doi.org/10.1016/S0091-6749(05)80170-8
  9. Lee, S. C., Guo, H., Li, W. M., Chan, L. Y. : Intercomparison of air pollutant concentrations in different indoor environment in Hong Kong. Atmospheric Environment, 36, 1929-1940, 2002 https://doi.org/10.1016/S1352-2310(02)00176-0
  10. Awad, A. H. A. : Environmental study in subway metro stations in Cairo, Egypt. Journal of Occupational Health, 44, 112-118, 2002 https://doi.org/10.1539/joh.44.112
  11. Jo, W. K., Seo, Y. J. : Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes. Chemospehre, 61, 1570-1579, 2005 https://doi.org/10.1016/j.chemosphere.2005.04.103
  12. Zuraimi, M. S., Tham, K. W. : Indoor air quality and its determinants in tropical child care centers. Atmospheric Environment, 42, 2225-2239, 2008 https://doi.org/10.1016/j.atmosenv.2007.11.041
  13. NIOSH (National Institute of Occupational, Safety and Health) : Sampling and characterization of bioaerosols. NIOSH Manual Analytical Methods, 4, 82-112, 1998
  14. Bullock, W. H., Ignacio, J. S. : A Strategy for assessing and managing occupational exposures, 3rd ed
  15. American Industrial Hygiene Association, Fairfax, VA, pp.349-355, 2006
  16. Lee, S. C., Li, W. M., Ao, C. H. : Investigation of indoor air quality at residential homes in Hong Kong. Atmospheric Environment, 36, 225-237, 2002 https://doi.org/10.1016/S1352-2310(01)00435-6
  17. Kim, K. Y., Roh, Y. M., Kim, Y. S., Lee, C. M.,Sim, I. S. : Profile of airborne microorganisms distributed in general offices. Korean Society of Occupational and Environmental Hygiene, 18(1), 11-19, 2008
  18. Charriere. N., Droz. P., Oppliger. A. : Effects of bioaerosol exposure on work-related symptoms among Swiss sawmill workers. International Arch Occupational Environment Health, 1, 12-17, 2007
  19. Guo, H., Lee, S. C., Chan, L. Y. : Indoor air quality investigation at air conditioned and non-air conditioned markets in Hong Kong. International Journal of Science Total Environment, 323, 87-98, 2004 https://doi.org/10.1016/j.scitotenv.2003.09.031
  20. Ren, P., Jankun, T. M., Belanger, K., Bracken, M.B., Leaderer, B. P. : The relation between fungal propagules in indoor air and home characteristics. Allergy, 56, 419-424, 2001 https://doi.org/10.1034/j.1398-9995.2001.056005419.x
  21. Tsai, M. Y., Liu, H. M. : Exposure to culturable airborne bioaerosols during noodle manufacturing in central Taiwan. International Journal of Science Total Environment, 10, 1016, 2008
  22. Mui, K. W., Wong, L. T., Hui, P. S. : Risks of unsatisfactory airborne bacteria level in air-conditioned offices of subtropical climates. Building and Environment, 43, 475-479, 2008 https://doi.org/10.1016/j.buildenv.2007.01.012
  23. Hirst, J. M., Stedman, O. J., Hogg, W. H. : Long distance spore transport : methods of measurement, vertical spore profiles and the detection of immigrant spores. Journal of General Microbiology, 48, 329-355, 1967 https://doi.org/10.1099/00221287-48-3-329
  24. Scheff, P. A., Paulius, V. K., Curtis, L., Conroy, L. M. : Indoor air quality in a middle school, Part 2:development of emission factors for particulate matter and bioaerosols. Applied Occupational and Environmental Hygiene, 15, 835-842, 2000 https://doi.org/10.1080/10473220050175715
  25. Lee, J. H., Jo, W. K. : Characteristics of indoor and outdoor bioaerosals at Korean high-rise apartment buildings. Environmental Research, 101, 11-17, 2006 https://doi.org/10.1016/j.envres.2005.08.009

피인용 문헌

  1. Concentrations of Airborne Fungi and Environmental Factors in the Subway Stations in Seoul, Korea vol.40, pp.2, 2014, https://doi.org/10.5668/JEHS.2014.40.2.81