• Title/Summary/Keyword: Indoor and outdoor

Search Result 1,342, Processing Time 0.024 seconds

Measurements of Indoor and Outdoor Volatile Organic Compounds(VOCs) Concentrations in Ambient Air (실내외 공기중 휘발성 유기화학물질(VOCs)의 농도조사에 관한 연구)

  • 신혜수;김윤신;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.310-319
    • /
    • 1993
  • A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.

  • PDF

Evaluation Method for Improvement of Indoor Air Quality Using Mass Balance (물질수지를 이용한 실내공기질 개선정도 평가)

  • Kim, Young-Hee;Kim, Moon-Hyeon;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.913-918
    • /
    • 2006
  • Despite the wide distribution of air pollutants, the concentrations of indoor air pollutants may be the dominant risk factor in personal exposure due to the fact that most people spend an average of 80% of their time in enclosed buildings. Researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide$(TiO_2)$ coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde and nitrogen dioxide emission rate in indoor environments by $TiO_2$ coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor net quality.

Indoor to Outdoor Ratio of Fine Particulate Matter by Time of the Day in House According to Time-activity Patterns (시간활동양상에 따른 주택의 시간대별 실내·실외 초미세먼지 농도비)

  • Park, Jinhyeon;Kim, Eunchae;Choe, Youngtae;Ryu, Hyoensu;Kim, Sunshin;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.504-512
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the 'Time-Use Survey' data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multifamily housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 ㎍/㎥, respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.

A Study for the Use of Solar Energy for Agricultural Industry - Solar Drying System Using Evacuated Tubular Solar Collector and Auxiliary Heater -

  • Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: The objectives of this study were to construct the solar drying system with evacuated tubular solar collector and to investigate its performance in comparison with indoor and outdoor dryings. Methods: Solar drying system was constructed with using CPC (compound parabolic concentrator) evacuated tubular solar collector. Solar drying system is mainly composed of evacuated tubular solar collector with CPC reflector, storage tank, water-to-air heat exchanger, auxiliary heater, and drying chamber. Performance test of solar drying system was conducted with drying of agricultural products such as sliced radish, potato, carrot, and oyster mushroom. Drying characteristics of agricultural products in solar drying system were compared with those of indoor and outdoor ones. Results: Solar drying system showed considerable effect on reducing the half drying time for all drying samples. However, outdoor drying was more effective than indoor drying on shortening the half drying time for all of drying samples. Solar drying system and outdoor drying for oyster mushroom showed the same half drying time. Conclusions: Oyster mushroom could be dried easily under outdoor drying until MR (Moisture Ratio) was reached to about 0.2. However, solar drying system showed great effect on drying for most samples compared with indoor and outdoor dryings, when MR was less than 0.5.

A Study on the Indoor Air Pollution Level and Its Health Significance in Working and Living Spaces (일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구)

  • Shin, Dong-Chun;Lee, Hyo-Min;Kim, Jong-Man;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.73-84
    • /
    • 1990
  • The study was carried out to investigate the extent of indoor air pollution in living rooms of apartment houses(residential area) and offices(traffic area A : no smoking space, B : smoking space) in Seoul and to determine the health significance of indoor air pollution. Indoor and outdoor concentrations of major air pollutants were observed simultaneously from February 13 to 17, and July 24 to 28, 1988. The concentrations of carbon monoxide(CO), nitrogen oxides(NOx), sulfur dioxide($SO_2$), carbon dioxide($CO_2$) and total suspended particulate(TSP) in living room and offices were measured and the results were summarized as follows: 1. Both in summer and in winter, the indoor concentrations of CO, $CO_2$, and TSP in offices were higher than the outdoor concentrations, on the other hand, $SO_2$ was higher in the outdoors and NOx was lower than the outdoor concentration only in office A where smoking is not permitted. 2. The indoor and outdoor pollution of offices in winter was significantly higher than that in summer, and the concentrations of CO, NOx and $SO_2$ in indoor and outdoor air in living room in winter were also higher than those in summer. These results suggest that indoor levels of air pollutants are affected by smoking and winter heating systems.

  • PDF

Effect of the Cultivation Technology on the Yield of Paddy Straw Mushroom (Volvariella volvacea)

  • Thi-Thuy-Hai Luu;Dang-Khoa Bui;Nga Huynh;Truc-Linh Le;Iain David Green
    • The Korean Journal of Mycology
    • /
    • v.50 no.3
    • /
    • pp.161-171
    • /
    • 2022
  • The edible paddy straw mushroom Volvariella volvacea (Bull. ex F.) Singer has high nutritional and medicinal values. They are grown on a wide variety of agricultural by-products using different several methods. The result of this present study showed that type of bed and cultivation condition (outdoor/indoor) had effects on the yield of paddy straw mushrooms grown on the spent oyster mushroom sawdust. The treatment of circular compact bed under indoor cultivation condition (CYIC) had the best yield and biological efficiency (B.E.) with 2,119.2 g/bed and 14.5%, respectively, followed by the treatment of conventional bed under outdoor cultivation condition (COOC) with the yield and B.E. of 1,935.5 g/bed and 13.2%, respectively, but the lowest yield and B.E. were observed in the treatment of conventional bed under indoor cultivation condition (COIC) with 1,226.1 g/bed and 8.4%, respectively. Paddy straw mushrooms cultivated on spent oyster mushroom sawdust should be proper in both outdoor and indoor conditions by conventional and circular compact methods as well. However, in indoor conditions, paddy straw mushrooms should be grown in a circular compact bed to ensure the temperature of the bed is suitable for the mushroom growth.

Variation of Indoor Air Quality in Museum (박물관 실내공기질 변동에 관한 연구)

  • 이정주;김신도;부문자
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season (여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성)

  • 이학성;강병욱;강충민;여현구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.193-201
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.

  • PDF

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.452-459
    • /
    • 1997
  • For computer aided design and construction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

A Study on Concentration of Indoor Nitrogen Dioxide in Relation to House Characteristics (주택특성에 관련된 실내 이산화질소 농도에 관한 연구)

  • 양원호;배현주;김현용;정문식;정문호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.85-92
    • /
    • 1999
  • Indoor air quality tends to be the dominant contributor to personal exposure because most people spend over 90% of their time indoors. For some contaminants, exposure to indoor air poses a potentially greater health threat than outdoor air exposures. Indoor nitrogen dioxide ($NO_2$) levels are mainly affected gas range, flue gas spillage, kerosene heaters, wood-burning appliances and cigarette smoke. In addition, indoor $NO_2$ levels are influenced by such house characterization as surface reaction and air exchange rate. In this study, the measurements of indoor and outdoor $NO_2$ concentrations were taken using identical protocols, and information was collected on housing characteristics using identical questionnaires in 14 houses out of 15 houses for daily 30 daily 30 days in Brisbane, Australia.The usage of gas range was the most contributing factor in indoor $NO_2$ concentration in relation to house characteristics. Average indoor and outdoor ratios of NO2 concentration in electronic and gas cooking houses were $0.6{\pm}0.1$ and $0.9{\pm}0.2$, respectively. The frequency distributions of $NO_2$ concentration in each house were approximately log-normal Geometric mean of indoor $NO_2$ concentrations of electronic and gas cooking houses for daily 30 days ranged from 2.5 ppm to 11.5 ppm with a mean 6.8 and from 4.7 ppm to 28.6 ppm with a mean 15.6 ppm, respectively. The $NO_2$ concentrations between electronic and gas cooking houses were significantly different (p<0.05). Since each house has different life-style and house characteristics, sampling interval to measure the $NO_2$ levels was recommended above 7 days.

  • PDF