• 제목/요약/키워드: Indoor air quality

검색결과 1,023건 처리시간 0.024초

Efficiency Evaluation of Adsorbents for the Removal of VOC and NO2 in an Underground Subway Station

  • Son, Youn-Suk;Kang, Young-Hoon;Chung, Sang-Gwi;Park, Hyun-Ju;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권2호
    • /
    • pp.113-120
    • /
    • 2011
  • Adsorbent combination studies have been carried out to remove nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs: BTEX) out of a subway environment characterized by high flow and low concentration. Optimal conditions for the high removal efficiency of the concerned target compounds were obtained through testing a series of control factors such as adsorbent sorts, thicknesses, and superficial velocity. It was found that the efficiencies increased as the specific surface area of activated carbon and its thickness increased, and external void fraction decreased. Furthermore, mixed activated carbon with granular and constructed contents was extensively tested to reduce pressure drop through the carbon bed. It was found that the performance of higher contents of granular activated carbon was better than that of higher contents of the constructed carbon. When the mixed carbon was applied to the subway ventilation system in order to eliminate $NO_2$ and VOC simultaneously, the removal efficiencies were found to be 75% and 85%, respectively.

사례분석을 통한 친환경 건축물 인증제도 개선방향 연구 (A Study of Case Analysis on Green Building Certification Criteria for Advanced Methods)

  • 모지선;김철;임태섭;강윤도;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.178-183
    • /
    • 2008
  • Recently, sick house syndrome caused by pollutants and contamination of buildings crops out in residential environment of buildings. According to price increase of global oil, comfort of occupants in indoor air quality is required with reduction of energy consumption and environmental load. So, building performance certification criteria come into effect for improvement of building energy efficiency and performance in environment at home and abroad. GBCC(Green Building Certification Criteria) of domestic country as a Criteria is managed Korea Green Building Council(KGBC) for green building. Thus, purpose of this study is to design a direction of Green Building Certification Criteria for improvement through analysis of GBCC application elements and selected building.

  • PDF

서울지하철 일부 역사 내 부유 곰팡이 농도 및 환경요인 (Concentrations of Airborne Fungi and Environmental Factors in the Subway Stations in Seoul, Korea)

  • 황성호;안재경;박재범
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.81-87
    • /
    • 2014
  • Objectives: We measured the concentrations of culturable airborne fungi (CAF) in enclosed environments at 16 underground subway stations of the Seoul Metro in 2013, and investigated the effect of environmental factors, including temperature, relative humidity, the number of passengers, and distance from the platform. Methods: The cultured fungi were identified by the lactophenol cotton blue (LPCB) staining method and were classified by observing the form, shape, and color of colony. A nonparametric analysis was used to determine if the differences in the concentrations of CAF were statistically significant. Results: The concentrations of CAF at the stations were the highest in station p ($367CFU/m^3$) with arange between 3 and $437CFU/m^3$. There was a significant correlation between CAF concentration and the distance from platform (r = 0.544, p < 0.01). Geotrichum spp. and Penicillium spp. were the predominant species. Conclusion: It is recommended that special attention be given during rush hour, which is in the morning (08:00-10:00) and in the early evening (18:00-19:00) to improve the indoor air quality of the subway stations.

공동주택 유형별 친환경 마감재 사용 실태분석 연구 (Actual Use Pattern of Environment-friendly Finish Materials in Recently-Constructed and Remodeled Apartment Houses)

  • 이지순
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.39-45
    • /
    • 2011
  • The concepts of interior design work have set forward an aesthetic and functional proposition to be answered by those who design spaces. The available range of suitable materials for interior use appears to be almost inexhaustible in this day and age. Now a day, relatively new fields of study on environmental-friendly interior examine humans'innate affinity for health and explore its implications for architecture and the built environment. A growing field of research suggests that spaces' relationship to aesthetics and environment can either help or hinder their occupants' health and wellness, productivity, and even their creativity. This paper presents several examples of already built apartment houses in practice, and discusses the demand of users of the spaces for health and sustainable environment, deepening the relationship between newly-constructed spaces and the remodeled ones. The considerations to some new and contemporary materials from the aspect of healthy indoor architecture design are presented in this paper. Designers need to rethink the conventional and high-tech interior environment in apartment houses with respect to perceived air quality, material emissions, and odors. The future of interior design is oriented on light shapeable materials which are able to create a unique memorable atmosphere. The primary assignment in accepting recent materials and proceedings is our responsibility to creating proposals, that are mainly safe, hygienic and environmentally proper.

보육시설의 실내공기질 유지관리 실태 (Indoor Air Quality in daycare facilities)

  • 박준석
    • 교육시설
    • /
    • 제21권6호
    • /
    • pp.28-32
    • /
    • 2014
  • 본 투고에서는 2008년 환경부의 용역으로 실시된 "보육시설의 실내공기질 진단 및 개선 시범사업"의 결과를 바탕으로 우리나라 보육시설의 실내공기 오염 실태와 함께 개선방안, 그리고 개선효과에 대하여 소개하였다. 서울, 경기, 인천 지역의 61개 시설을 대상으로 실내공기질 측정과 설문조사를 실시한 결과 폼알데하이드와 총 휘발성유기화합물은 일부시설에서 "다중이용시설 등의 실내공기질 관리법" 기준치를 초과하는 것으로 나타났다. 반면 이산화탄소와 미세먼지는 조사 대상 시설 중 50 % 이상이 기준치를 초과하는 것으로 나타났다. 따라서 보육시설의 실내공기질 개선을 위해서는 각 오염물질의 발생원별로 유지관리 대책이 필요한 것으로 조사되었다. 또한 오염원인별 분석결과, 대부분 시설의 실외오염물질 농도가 실내보다 낮게 나타나 외기의 오염이 실내에 미치는 영향은 미비한 것으로 나타났으며, 계절에 따른 실내공기오염은 동절기에 낮은 외기온도로 인하여 실내를 하기 때문에 하절기에 비해 더 높게 나타났다. 공간에 따른 오염물질의 농도는 이산화탄소와 미세먼지의 경우 아동이 늘 상주하는 교실의 오염이 가장 심한 것으로 나타났으며 폼알데하이드와 총휘발성유기화합물의 경우 놀이실의 오염도가 교실에 비해 더 높게 나타났다. 개선방안별 개선효과에 있어서는 환기계획 몇 환기설비 설치, 지하공간 습기 문제 개선에서 가장 높은 효과가 나타났다. 향후 보육시설의 쾌적하고 건겅한 실내환경의 유지관리를 위해서는 보육종사자들이 활용할 수 있는 유지관리 지침 또는 매누얼에 대한 보급이 필요할 것으로 판단된다.

PC방에서의 간접흡연에 따른 요중 코티닌의 농도

  • 박용선;노영만;김치년
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.6-8
    • /
    • 2002
  • Many adolescents stay long time in the PC game room and are exposed to much of tobacco smoke. To evaluate the effect of passive smoking in the PC game room, airborne nicotine concentrations and urinary cotinine concentrations were measured for 20 adolescents at 2 PC game rooms in Sung-nam city. And the subjects were interviewed for duration and time in PC game room and smoking pattern. Subjects are composed of each of 10 smokers(5 males and 5 females) and 10 non-smokers(5 males and 5 females). They stayed for three hours in the PC game room without smoking. Concentrations of nicotine in smokers and non-smokers were 129.72 $\mu\textrm{g}$/㎥ and 99.99 $\mu\textrm{g}$/㎥, respectively. Urinary cotinine concentrations were increased as time goes on after exposure to nicotine and showed maximum value at 9.45 hours after nicotine exposure and were 32.21 and 110.66 $\mu\textrm{g}$/L for non-smoker and smokers. Urinary cotinine has a tendency to be increased by passive smoking. Therefore, it is recommended that the effective control for indoor air quality and extensive research be needed to reduce nicotine concentration by passive smoking in the PC game room.

  • PDF

SK케미칼 연구소에 적용된 친환경 기술 적용 효과 분석 - 에너지 및 수자원 절감 적용 효과를 중심으로 - (The Analysis on Eco-friendly Technologies Effect Applied to SK Chemicals R&D Center)

  • 유지용;이유하;이영렬;양재웅;박현근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • The SK Chemical R&D center is an eco-friendly building designed as top score in the GBCC(GREEN BUILDING CERTIFICATE CRITERIA). This building has applied various eco-friendly technologies such as energy /water resource cutdown, improvement of indoor quality and improvement of user convenience, etc through eco-friendly concept from the design phase. In this thesis, an economic efficiency evaluation has been performed on building energy cwater resource cutdown technologies among them and the results are as follows. The building energy has cut down about 40% compared to ordinary buildings and the investment recovery period was shown as about 5 years. The water resource has cut down about 63% compared to ordinary buildings and the investment recovery period was shown as about 10 years.

  • PDF

국내 의료기관의 환기설비 운영실태 및 인식 조사 (Investigation on Ventilation Mmethod and Recognition of Users in Healthcare Facilities of KOREA)

  • 조성민;성민기
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권2호
    • /
    • pp.7-14
    • /
    • 2018
  • Purpose: The outbreak of Middle East Respiratory Syndrome(MERS) in KOREA has brought up the demands for ventilation guideline and regulations for healthcare facilities since most of the infection was spreaded inside healthcare facility. Currently KOREA has no ventilation guideline or regulations covering entire section of healthcare facility. The purpose of this study is to investigate current ventilation methods in KOREA healthcare facilities to in future, propose ventilation guideline. Methods: Research of foreign counties ventilation guideline and regulation for healthcare facilities were conducted for reference. Field investigation with survey of 21 healthcare were conducted to identify the ventilation system and operating methods. Additionally survey for healthcare workers were conducted to observe the recognition related to ventilation system in healthcare facility. Results: The result showed that most of foreign countries ventilation guideline and regulation suggests similar items to reduce the spread of infection and maintain good indoor air quality. The investigation results indicated that fixed guideline for ventilation in healthcare facility were required due to different ventilation operating methods. Survey result of healthcare workers has told us that ventilation guideline and regulation is needed to prevent further infection. Implications: Absence of ventilation guideline and regulations for healthcare facility in KOREA is an urgent issue.

신축 및 리모델링 유치원의 휘발성유기화합물 농도 실태 (Actual State of TVOC and HCHO Concentration in Newly Built or Remodeled Kindergarten)

  • 최윤정;박은비;안지선
    • 한국생활과학회지
    • /
    • 제18권6호
    • /
    • pp.1363-1374
    • /
    • 2009
  • The purpose of this study was to determine the actual state of the indoor air quality in newly built or remodeled kindergartens by TVOC and HCHO concentration and teachers' responses. The field measurements on the levels of TVOC and HCHO were carried out in six classrooms of newly built or remodeled kindergartens before their opening. The interviews with teachers of subject kindergartens were carried out at the end of the first semester. The contents of the interviews were teachers' subjective responses and symptoms of the kindergarten pupils on the Sick New-School Syndrome. The results are as follows; the mean value of TVOC concentration in the classrooms of kindergartens ranged from 0.10ppm to 0.42ppm, which can theoretically exert a harmful influence on residents. The mean value of HCHO concentration ranged from 0.00ppm to 0.03ppm, which does not exceed the standard. The TVOC concentrations of the more ventilated kindergartens were lower than the others. Also, the classrooms with high concentrations of TVOC showed negative responses or symptoms in teachers and kindergarten pupils.

Soybean-based Green Adhesive for Environment-friendly Furniture Material

  • Jeon, Ji-Soo;Lee, Jeong-Hun;Kim, Su-Min
    • 한국가구학회지
    • /
    • 제22권3호
    • /
    • pp.174-182
    • /
    • 2011
  • Over the last decade, Sick Building Syndrome has become a significant social issue in Korea and many methods have been considered to maintain comfortable indoor air quality. To reduce toxic substances emitted from wood composite products, the source control is an efficient method through the reduction of formaldehyde content by using natural material-based adhesives for composite wood products production. Among alternative materials, soybean protein is considered an appropriate natural material to replace formaldehyde-based resin and many efforts have been made to produce new products, such as soap, shampoo, ink, resin, adhesive and textile through changing the chemical or physical properties of soybean. To process soybeans into these useful products, the beans are dehulled and the oil is removed by crushing at very high pressure or by solvent extraction. For use soybean as an adhesive, it is processed at temperatures below $70^{\circ}C$ to preserve the alkaline solubility of the proteins. In addition, soybean-based adhesive is undergone treatment process to improve mechanical properties using urea, urease inhibitor N-(n-butyl) thiophosphoric triamide and sodium dodecyl sulfate. The modified soybean-based adhesive exhibited sufficient mechanical properties to use as an adhesive for composite wood products. This paper is a review article to discuss the possibilities of soybean-based adhesive for environment-friendly furniture materials.

  • PDF