• Title/Summary/Keyword: Indoor air quality

Search Result 1,011, Processing Time 0.042 seconds

Study on the Improvement Process for the Food Waste Resource Facility (II) - Focus on Deodorization Facility of DDM Environment Resource Center - (음식물류 폐기물 자원화시설의 공정개선에 관한 연구(II) - DDM환경자원센터의 탈취시설 사례를 중심으로 -)

  • Kim, Choong-Gon;Bae, Yoonhwan;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • This study refers to the deodorization of DDM Environmental Resource Center, which is operating abnormally in the food waste public-resource facilities that are operating nationwide, in accordance with the initial operating conditions. Issues concerning the abnormal deodorization facilities of DDM Environment Resource Center were the deodorization of composting facilities, indoor air quality problems, and overall deodorization of facilities, especially the phenomenon of stopping while operating the RTO and the phenomenon of poor spray in the wet scrubber etc. As an alternative and improvement method for converting such abnormal operation facilities into normal operation facilities, It is proposed to remove the front filter of the upper part of the fermentation tank, and to install scrubbers, air and water separator, and roll filters for dust removal etc.

A Delphi Study on Competencies of Future Green Architectural Engineer (근미래 친환경 건축분야 엔지니어에게 필요한 역량에 대한 델파이 연구)

  • Kang, So Yeon;Kim, Taeyeon;Lee, Jungwoo
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.56-65
    • /
    • 2018
  • With rapid advance of technologies including information and communication technologies, jobs are evolving faster than ever. Architectural engineering is no exception in this regard, and the green architectural engineering is emerging fast as a promising new field. In this study, a Delphi study of expert architectural engineers are conducted to find out (1) near future prospects of the field, (2) near future emerging jobs, (3) competencies needed for these jobs, and (4) educational content necessary to build these competencies with regards to the green architectural engineering. Initial Delphi survey consisting of open-ended questions in the above four areas were conducted and came out with 65 items after duplicate removal and semantic refinements. Further refinements via second and third wave of Delphi results into 40 items that the 13 architectural engineering experts may largely agree upon as future prospects with regards to the green architectural engineering. Findings indicate that it is expected that the demand for green architectural engineering and needs for automatic energy control system increase. Also, collaborations with other fields is becoming more and more important in green architectural engineering. The professional work management skills such as knowledge convergence, problem solving, collaboration skills, and creativity linking components from various related areas seem to also be on the increasing need. Near future ready critical skills are found to be the building environment control techniques (thermal, light, sound, and air), the data processing techniques like data mining, energy monitoring, and the control and utilization of environmental analysis software. Experts also agree on new curriculum for green building architecture to be developed with more of converging subjects across disciplines for future ready professional skills and experiences. Major topics to be covered in the near future includes building environment studies, building energy management, energy reduction systems, indoor air quality, global environment and natural phenomena, and machinery and electrical facility. Architectural engineering community should be concerned with building up the competencies identified in this Delphi preparing for fast advancing future.

Performance Evaluation of Fine-Dust Blocking Effect of Functional Clothing (미세먼지 차단 기능성 의류 제품의 성능 평가에 관한 연구)

  • Seok-Ju, Hwang;Chang-Hoon, Lee;Jin-Kyung, Kwon;Young-Sil, Kim;Eun-Jin, Choi;Da-Jin, Kim;Min, Kim;Se-Jin, Yook
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • As many studies on the harmfulness of fine dust have been reported, awareness of its seriousness is spreading. Recently, interest in indoor air quality as well as air pollution is increasing, and research on measures to block fine dust flowing into the room from the outside is being conducted. The clothing company is launching functional clothing to prevent fine dust attached to clothing from entering the room through outdoor activities. However, it is difficult to confirm whether there is actually fine-dust blocking performance, and there is no evaluation standard. In this study, the contamination rate caused by fine dust was quantitatively compared through image processing after contamination of the outer fabric for 4 types of commercially available functional clothing with fine-dust blocking effect. The difference in particle contamination according to the material of the outer fabric was analyzed by comparing the surface resistance, and it was found that the higher the surface resistance of the outer fabric material, the more fine dust was attached. The analysis method of this study is expected to be able to quantitatively compare and evaluate the fine-dust blocking performance of functional clothing.

Development of a building materials database; Volatile organic compounds, formaldehyde emission rates and chemical compositions (건축자재의 오염물질 방출 데이터베이스 개발; 휘발성유기화합물, 폼알데하이드 방출강도 및 화학조성)

  • Yu, Young-Jae;Lee, Chul-Won;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • A material database has been developed for VOCs and formaldehyde emitted from building materials in this study. New classification system has been made by correlating the classification methods used in Korean Air Cleaning and Environmental Protection Agency. The developed databases include emission rates of TVOC, 5VOC and formaldehyde emitted from each building material. In addition, the databases can be used as an input variable to estimate indoor air quality (IAQ) using computer simulation since they also contain chemical component and general imformation. Box plot was used to do statistical analysis for emission rates of formaldehyde and TVOCs from different types of building materials. Also we confirmed the building materials worsening IAQ by categorizing the emission characteristic of different types of pollutants.

Systematic Review on International Practices in Controlling Waterpipe Tobacco Smoking

  • Tee, Guat Hiong;Hairi, Noran N;Nordin, Fauziah;Choo, Wan Yuen;Chan, Ying Ying;Kaur, Gurpreet;Veerasingam, Pathma Devi;Bulgiba, Awang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3659-3665
    • /
    • 2015
  • Background: Waterpipe tobacco smoking has becoming popular especially among young people worldwide. Smokers are attracted by its sweeter, smoother smoke, social ambience and the misconception of reduced harm. The objective of this study was to systematically review the effects of waterpipe tobacco policies and practices in reducing its prevalence. Materials and Methods: A systematic review was conducted electronically using the PubMed, OVID, Science Direct, Proquest and Embase databases. All possible studies from 1980 to 2013 were initially screened based on titles and abstracts. The selected articles were subjected to data extraction and quality rating. Results: Three studies met the inclusion criteria and were eligible for this review. Almost all of the waterpipe tobacco products and its accessories did not comply with the regulations on health warning labelling practices as stipulated under Article 11 of WHO FCTC. In addition, the grisly new warning labels for cigarettes introduced by Food and Drug Administration did not affect hookah tobacco smoking generally. Indoor air quality in smoking lounges was found to be poor and some hookah lounges were operated without smoke shop certification. Conclusions: Our findings revealed the availability of minimal information on the practices in controlling waterpipe smoking in reducing its prevalence. The lack of comprehensive legislations or practices in controlling waterpipe smoking warrants further research and policy initiatives to curb this burgeoning global epidemic, especially among the vulnerable younger population.

Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan (서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성)

  • Lee, Tae-Jung;Lim, Hyoji;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

Reviews on an Improvement and Measurement of the Hydrophobicity for Carbon Materials (탄소재료의 소수성 향상 방법 및 측정 방법에 대한 고찰)

  • Kang, Yu-Jin;Kim, Yu-Jin;Jang, Min-Hyeok;Jo, Hyung-Kun;Yoon, Seong-Jin;Han, Gyoung-Jae;Cho, Hye-Ryeong;Seo, Dong-Jin;Park, Joo-Il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.41-50
    • /
    • 2022
  • Recently, research on carbon adsorbents has been active as an interest in improving the environment such as indoor and outdoor air quality. Considering that causative substances deteriorate the air quality are basically volatile organic compounds, it is important to improve the hydrophobicity of the carbon materials for better removal efficiency. This study presents a method for improving hydrophobicity of carbon and a measurement of the hydrophobicity. Generally, methods of improving the hydrophobicity of carbon materials are heat treatment, acid/alkali treatment, coating and immersion with hydrophobic materials. However, it collapses the pore structure and reduces the adsorption capacity. Therefore, this study briefly introduce not only the general method for improving carbon materials' hydrophobicity but also the method for converting the precursor of the material is briefly introduced. Futhermore, this study introduces a analytical technique used to determine hydrophobic modification or not, and aims to enhance the understanding of carbon materials.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Ju, Jung-Kyeong
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • The ventilation frequency of 0.5 times in residential facilities is applied mandatorily to the housing facilities containing more than 100 house units to improve the indoor air quality and create comfortable interior conditions and pleasantness for residents. The Building Energy Efficiency Rating system requires the implementation of leakage test based on ventilation frequency with the test results being reflected in the efficiency ratings, thereby stimulating the precise construction of the fittings in the periphery of windows and savings of energy that can be lost due to the infiltration air. The inspection results of the Building Energy Efficiency Rating at the site showed that the ventilation frequency was in the range between 0.63 and 0.71 and that the difference was found to have a significant effect on the amount of energy reduction. It is urgent to conduct the study on highly leakage-proof buildings and construction methods, along with the expansion of mandatory leakage-proof diagnosis of non-residential buildings, considering the mandatory ventilation frequency below 0.6 for passive houses under the European standards and the target set by Korea to introduce the passive house, the rigorous standard for energy efficiency in buildings and mitigating their ecological footprint, by 2017 and achieve the zero house by 2025.

Characterisation of fungal contamination sources for use in quality management of cheese production farms in Korea

  • Kandasamy, Sujatha;Park, Won Seo;Yoo, Jayeon;Yun, Jeonghee;Kang, Han Byul;Seol, Kuk-Hwan;Oh, Mi-Hwa;Ham, Jun Sang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.6
    • /
    • pp.1002-1011
    • /
    • 2020
  • Objective: This study was conducted to determine the composition and diversity of the fungal flora at various control points in cheese ripening rooms of 10 dairy farms from six different provinces in the Republic of Korea. Methods: Floor, wall, cheese board, room air, cheese rind and core were sampled from cheese ripening rooms of ten different dairy farms. The molds were enumerated using YM petrifilm, while isolation was done on yeast extract glucose chloramphenicol agar plates. Morphologically distinct isolates were identified using sequencing of internal transcribed spacer region. Results: The fungal counts in 8 out of 10 dairy farms were out of acceptable range, as per hazard analysis critical control point regulation. A total of 986 fungal isolates identified and assigned to the phyla Ascomycota (14 genera) and Basidiomycota (3 genera). Of these Penicillium, Aspergillus, and Cladosporium were the most diverse and predominant. The cheese ripening rooms was overrepresented in 9 farms by Penicillium (76%), while Aspergillus in a single farm. Among 39 species, the prominent members were Penicillium commune, P. oxalicum, P. echinulatum, and Aspergillus versicolor. Most of the mold species detected on surfaces were the same found in the indoor air of cheese ripening rooms. Conclusion: The environment of cheese ripening rooms persuades a favourable niche for mold growth. The fungal diversity in the dairy farms were greatly influenced by several factors (exterior atmosphere, working personnel etc.,) and their proportion varied from one to another. Proper management of hygienic and production practices and air filtration system would be effective to eradicate contamination in cheese processing industries.