• 제목/요약/키워드: Indoor air environment

검색결과 1,058건 처리시간 0.029초

Photocatalytic Oxidation of Indoor Air Volatile Organic Compounds (VOCs) in pub Level

  • Jo, Wan-Kuen;Kim, Dong-Hyun;Ki, Jae-Chang;Huh, Jeung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E4호
    • /
    • pp.157-168
    • /
    • 2003
  • This study evaluated the technical feasibility of the application of titanium oxide (TiO$_2$) photocatalysis for the removal of VOCs in low ppb concentrations commonly associated with non -occupational indoor air quality issues. A series of experiments were conducted to evaluate four parameters (relative humidity (RH), hydraulic diameter (HD), photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs presented significant dependency on the RH, which is inconsistent with a few previous studies. However, it is noted that the three parameters (HD, RM and IPS) should be considered for better VOCs removal efficiencies for the application of TiO$_2$ photocatalytic technology for cleansing non -occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO would be negligible in comparison to the indoor CO levels. These results can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태 (The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students)

  • 최윤정;김운학
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로- (Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants -)

  • 백성옥;김윤신
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

공동주택의 실내 열환경에 대한 평가방법개발 (Development of Methods for Evaluation of Indoor Thermal Environment of Apartment Housing)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제35권6호
    • /
    • pp.101-110
    • /
    • 1997
  • The intent of this study is to propose a method for appraisal of the indoor thermal environment of apartment housing by measuring physical factors and residents' response to questionnaire survey. The experiments were performed on eight houses each in summer (August 18 through 31,1995) and winer (february 16 through 20,1996). It included measurements of indoor air temperature, globe temperature, relative humidity, and CO2 concentration. The questionnaire surveys were performed each in summer (July 16 through 20, 1996) and winer (February 13 through 16, 1996). And 248 cases in summer and 297 cases in winter were used in analysis. These questionnaire surveys asked residents' response about thermal sensation, humidity sensation, sense of air freshness regarding the indoor thermal environment. data acquired through the experiments and questionnaire surveys were then transferred to scales that allowed relative comparison, and measured to an appraisal standard chart. Appraisal tools included appraisal charts and radar charts. Indoor thermal environment was judged to be positive according to experiments, but residents appraised the thermal environment to be average. This difference between the two can be found in the strict standards by which residents judge the thermal environment of their apartments.

  • PDF

현장측정을 통한 대형 할인매장의 실내환경 평가 (Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores)

  • 박병윤;정용호;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of $CO_2$, CO gas and TSP were measured and evaluated. In each case of $CO_2$, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from $18^{\circ}C$ to $28^{\circ}C$ according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

지하수로부터의 실내 라돈오염시 인체노출평가 (Assessment of Human Exposures to Indoor Radon Released from Groundwater)

  • 유동한;김상준;양지원
    • 한국대기환경학회지
    • /
    • 제17권3호
    • /
    • pp.241-249
    • /
    • 2001
  • A report by the National Research Council in the United States suggested that many lung cancer deaths each year are associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundation. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the assessment of a exposure to radon released from the groundwater into indoor air. At first, a 3-compartment model is describe the transfer and distribution if radon released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such radon for adults based on two sets of exposure scenarios, Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

학교 실내 환경의 실내공기질 인식에 관한 연구 (A study of Recognition of Indoor Air Quality of Indoor Environment at School)

  • 홍은주;김정덕;전용택;이치원;문정숙;손부순
    • 환경위생공학
    • /
    • 제22권3호
    • /
    • pp.51-64
    • /
    • 2007
  • This research, selected for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003, in order to study of Recognition of Indoor Air Quality of Indoor Environment at School. we used Questionnaire for 193 health teachers, 41 teachers, and 1,359 students. The results of study are as follows. 1. To the question 'Currently Were you damage caused by classroom air?', showed that worry class teachers more than students with 43.9% of class teachers, 35.9% of health teachers and 23.5% of students. 2. To the question 'What would be an efficient way to manage classroom sanitation?', 50% of class teachers, 40.5% of health teachers and 47.4% of students wanted 'installation of air purifier.' 3. To the question 'How are you getting information about indoor air pollution?', showed that all of 3 groups get information through on TV. 4. According to survey, Health teachers who act as health supervisors appeared to have more prior knowledge air quality than class teachers and students. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. Therefore, these results suggested that a logical and systematic education program for students about the importance of indoor air quality should be carried out.

煖房器具를 사용하는 室內空氣중의 벤조(a) 피렌 成分濃度에 관한 硏究 (Benzo(a) pyrene Level in Indoor Environment due to the Use of Unvented Heating Facilities)

  • 董宗仁
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.65-73
    • /
    • 1987
  • Indoor air pollution problems, in fact, have been neglected due to the unawareness of its seriousness and the lack of accumulated data. Recently, some movement of research and regulations, however, have been made for several indoor air pollutants. In this study, one of the carcinogenic polynuclear aromatic hyrocarbon, Benzo(a) pyrene in indoor airborne particulate, was measured and analyzed to estimate emission strength of BaP from an unvented kerosene heater and to know its level in indoor environment with use of a kerosene heater and a wood-burning fireplace. By the measurement of BaP level in a dark room with air exchange rate of app. 3.0, BaP emission strength of a kerosene heater (11,000Btu/hr) was estimated to be 326.6ng/hr (or 29.7 ng/$10^3$ Btu). With 4-hr operation a day of the kerosene heater in an apartment, the BaP level became 2.97ng/m$^3$ from 0.27ng/m$^3$ of background level. The operation of a wood-burning fireplace app. 2hr a day, on the other hand, increased the BaP level from 0.16ng/m$^3$ of background to 3.53ng/m$^3$. So proper ventilation must be considered seriously when unvented heating facilities are used in indoor environment.

  • PDF

대공간의 바닥 복사 난방 적용에 관한 연구 (A Study on Application of Radiant Floor Heating in Large Space)

  • 안민희;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.79-85
    • /
    • 2007
  • This paper addresses the indoor air quality when radiant floor heating is applied in large space. Radiant heat exchange between surfaces depends on the orientation and the temperature of the surfaces. Also, the temperature and the radiant characteristic of the wall and the roof that face the floor have great influence on the indoor air environment due to the largeness of the wall and the roof in large spaces. In this study, we simulate a test-cell(25X20X10) using a ies YE And using a CFD(microflo in VE), an indoor air environment was investigated to establish the optimum temperature of floor. At the first time of the heating, high floor temperature is demanded. At the middle of the heating, however, the temperature of the residential space was formed appropriately, although the temperature of the floor was set low.