• 제목/요약/키워드: Indoor acoustic environment

검색결과 26건 처리시간 0.022초

주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로 (Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province)

  • 윤성훈;윤희진
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

PMV와 음환경의 복합 작용이 실내 환경 지각에 미치는 영향 (Combined Effects of PMV and Acoustics on Indoor Environmental Perception)

  • 양원영
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.135-142
    • /
    • 2016
  • Purpose: The purposes of this paper are to investigate effects of indoor thermal environment on acoustical perception and effects of acoustics on indoor thermal perception, and to understand basic human perception on indoor environment. Method: Subjective assessment was performed in an indoor environmental chamber with 24 university students. Thermal conditions with PMV -1.53, 0.03, 1.53, 1.83 were simulated with a VRF system, a humidifier, a dehumidifier, and a ventilation system. Six noise sources - Cafe, Fan, Traffic, Birds, Music, Water- with sound levels of 45, 50, 55, 60 dBA were played for 2 minutes in random order. Temperature sensation, temperature preference, humidity sensation, humidity preference, noisiness, loudness, annoyance, and acoustic preference were assessed using bipolar visual analogue scales. The ANOVA and Turkey's post hoc test were used for data analysis. Result: Thermal environmental perceptions were not altered through 2 minutes noise exposure. Acoustical perceptions were altered by thermal conditions. The results were consistent with previous papers, however, the noise exposure time should be carefully considered for further development.

Acoustic Driving Simulator Design for Evaluating an In-car Speech Recognizer

  • Lee, Seongjae;Kang, Sunmee
    • 말소리와 음성과학
    • /
    • 제5권2호
    • /
    • pp.93-97
    • /
    • 2013
  • This paper is on designing an indoor driving simulator to evaluate the performance of in-car speech recognizer when influenced by the elements, which lower the success rate of speech recognition. The proposed simulator simulates vehicle noise which was pre-recorded in diverse driving environments and driver's speech. Additionally, the proposed Lombard effect conversion module in this simulator enables the speech recorded in a studio environment to convert into various possible driving scenarios. The relevant experimental results have confirmed that the proposed simulator is a feasible approach for realizing an effective method as it achieved similar speech recognition results to the real driving environment.

청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구 (An Experimental Study on the noise Rating of H.D. TV sets by Psycho-acoustic Experiments)

  • 이주엽;박현구;이태강;김희진;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.862-869
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise in residential condition. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

  • PDF

청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구 (An Experimental Study on the Noise Evaluation of H.D. TV sets by Psycho-acoustic Experiments)

  • 이주엽;이태강;김희진;김선우
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1014-1023
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. Finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

실내에서 음향신호의 RSPD를 이용한 청음각 추정 기법 (A Listening Angle Estimation Scheme based on Received Signal Power Differences in Indoor Environment)

  • 이의형;유승수;윤은철;김선용
    • 한국통신학회논문지
    • /
    • 제35권12C호
    • /
    • pp.1035-1043
    • /
    • 2010
  • 본 논문에서는 실내 환경에서 음원과 수신마이크 사이의 거리에 따른 음향신호 수신세기 감소 특성을 이용하여 수신전력세기차 기반 청취자 각도 추정 기법을 제안하고, 이 기법의 각도 추정성능을 분석한다. 제안한 법으로 청취자의 각도를 추정하기 위해 사용하는 측정치는 수신전력세기간의 차이이며 이는 각도 추정을 위한 측정치로서 본 논문에서 처음 고려되었다. 제안한 기법을 이용하여 청취자 각도를 추정했을 때 발생하는 오차를 수학적으로 모델링하여 분석하고 모의실험 및 실측실험을 통해 제안한 기법의 성능을 보인다.

강의전용 공간으로 리모델링된 대학 소공연장의 주관적 음향성능 평가 : W대학의 사례를 바탕으로 (Evaluation of the Subjective Acoustic Performance of University Small Hall Remodeled as a Lecture Room : Based on the case of the W University)

  • 김민주;김재수
    • 교육녹색환경연구
    • /
    • 제19권4호
    • /
    • pp.40-49
    • /
    • 2020
  • 교육의 기본적인 형태는 지식의 전달, 즉 음성 전달을 통해 교수가 교육수요자에게 지식을 전달하는 방식이므로 쾌적한 학습 환경 조성에 있어 음환경은 필수적인 고려 요소이다. 실내 음환경은 재실자의 정신적 스트레스와 매우 밀접한 연관성을 가지고 있으므로 적절한 음환경의 조성 여부에 따라 교육의 질적 수준 또한 크게 변화할 것이다. 따라서 본 연구에서는 선행연구에서 제시한 물리적 음향성능 자료를 바탕으로 가청화 기법을 활용한 청감실험을 실시하였으며 이를 통해 강의전용 공간의 물리적 음향성능 개선에 따른 주관적 음향성능의 만족도 변화를 분석하였다. 연구는 강의전용 공간에서 주로 사용되는 음원 6개를 선정하여 8개의 어휘로 평가를 진행하였다. 연구 결과, 음향성능의 개선에 따라 주관적 음향성능도 개선되었으며 소공연장을 강의전용 공간으로 리모델링한 후 "음악"에 대한 주관적 반응보다 "음성"에 대한 주관적 반응이 긍정적으로 나타나 음성 전달에 보다 적합한 공간으로 개선되었음을 확인하였다. 따라서 본 연구를 통해 교육시설의 음환경 개선 시 물리적 음향성능 뿐만 아니라 청감실험을 통한 주관적 음향성능 검증의 필요성을 강조하고자 하였다.

현장측정을 통한 발코니 창호의 차음성능에 관한 연구 (Investigation of the sound insulation performance of balcony window through field measurement)

  • 주문기
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.63-68
    • /
    • 2009
  • As with the disappearance of a living room window due to the trend in apartment housing construction that prefers a larger, expanded living room, the sound insulation performance of the balcony window is becoming an important factor to determine the level of indoor noise at an apartment unit. Considering that the indoor noise inside an apartment unit is mandated by law at or below 45dB(A), the balcony window is increasingly assuming an even more important role. Sound insulation performance of the window was measured by examining differences in data involving varying angles of incidence of the sound source as obtained from the same balcony window. Also, acoustic intensity measuring was performed at and around the window to determine its sound insulation quality. Results of measuring on the sound source's angles of incidence indicated that the performance showed some differences in lower frequency ranges, though with no significance. Intensity measuring results showed that the sound insulation performance was reduced near the connection part of the window and the window frame.

측정방법별 가전제품의 음향파워레벨 (Sound Power Level of Electric Home Appliances according to Measurement Method)

  • 강대준;구진회;이재원
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.335-346
    • /
    • 2009
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. This results will help us predict the indoor noise level using the basic data of sound power level.