• Title/Summary/Keyword: Indoor Thermal Conditions

Search Result 139, Processing Time 0.023 seconds

A Study on the Indoor Comfort Control By Smart Comfort Algorithm (스마트 쾌적 알고리즘을 적용한 실내 쾌적 제어에 대한 연구)

  • Yoon, Seok-Am;Lee, Jeong-Il
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.603-609
    • /
    • 2015
  • Thermal comfort is one of the fundamental aspects of indoor environmental quality and it is strongly related to occupant satisfaction and energy used in building. In this paper, we proposes smart comfort algorithm that save energy and provide a pleasant and comfortable environment for workers by the indoor comfort conditions(Predictive Mean Vote) detection and controlling the temperature and humidity, air flow. Simulation results, heating and cooling control of the thermal comfort control can be compared with the existing general air conditioners reduces the power of 0.5kW and indoor comfort can be maintained. Also, It showed a 49.2% improvement in the light by lighting control algorithm.

Development of Integrated Control Methods for the Heating Device and Surface Openings based on the Performance Tests of the Rule-Based and Artificial-Neural-Network-Based Control Logics (난방시스템 및 개구부의 통합제어를 위한 규칙기반제어법 및 인공신경망기반제어법의 성능비교)

  • Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.97-103
    • /
    • 2014
  • This study aimed at developing integrated logic for controlling heating device and openings of the double skin facade buildings. Two major logics were developed-rule-based control logic and artificial neural network based control logic. The rule based logic represented the widely applied conventional method while the artificial neural network based logic meant the optimal method. Applying the optimal method, the predictive and adaptive controls were feasible for supplying the advanced thermal indoor environment. Comparative performance tests were conducted using the numerical computer simulation tools such as MATLAB (Matrix Laboratory) and TRNSYS (Transient Systems Simulation). Analysis on the test results in the test module revealed that the artificial neural network-based control logics provided more comfortable and stable temperature conditions based on the optimal control of the heating device and opening conditions of the double skin facades. However, the amount of heat supply to the indoor space by the optimal method was increased for the better thermal conditioning. The number of on/off moments of the heating device, on the other hand, was significantly reduced. Therefore, the optimal logic is expected to beneficial to create more comfortable thermal environment and to potentially prevent system degradation.

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

Evaluation of Thermal Comfort during Sleeping in Summer - Part IV : Study on Indoor Temperature Conditions for Comfort Sleep - (여름철 수면시 온열쾌적감 평가 - 제4보 : 쾌적수면을 위한 실내온도 설정에 관한 연구 -)

  • Kum, Jong-Soo;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.307-312
    • /
    • 2007
  • This study was performed to evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of sleep efficiency and MST under four thermals conditions ($22^{\circ}C,\;24^{\circ}C,\;26^{\circ}C,\;30^{\circ}C$). Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. Their age was from 20 to 22 years old. They were healthy, and had regular sleep with consistent bed and wakeup time. It was checked whether they had a good sleep before the night of experiment. Experiments were performed in an environmental chamber using thermo-hygrostat. The physiological signal (EEG) for sleep stage were obtained from C3-A2 and C4-Al electrode sites. Sleep stages were classified, then SWS latency and SWS/TST were calculated for the evaluation for sleep efficiencies on thermal conditions. As results, mean skin temperature for comfort sleeping was $34.5{\sim}35.4^{\circ}C$. Considering sleep efficiency and mean skin temperature, indoor room temperature of upper limit was $28.1^{\circ}C$.

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

Analysis of a Wet Surface Finned-tube Evaporator of an Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.211-219
    • /
    • 2002
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. Since current procedure underpredicted the experimental sensible heat factor (SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test is necessary.

Performance Analysis of Indoor GHP for R410A Application (R410A 냉매를 이용한 GHP용 고효율 실내기 성능특성)

  • Lee, Jong-Ho;Park, Chang-Sug;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.447-452
    • /
    • 2009
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchanger with R410A. This study carried out experimental and numerical analysis for indoor heat exchangers. In the experimental study, capacity of the indoor unit was estimated 8.3 kWh with the valve opening rate of 95% for the 50% partial operation condition. The air temperatures were measured using 80 thermocouples. This study also compared experimental data with the calculated data for the outlet temperature and the tube length. It is found that the relative errors between the experiment data and the calculated result are 4.2% and 0.5% for the outlet temperature and the tube length, respectively.

  • PDF

Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province (주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로)

  • Yoon, Sung-Hoon;Yun, Hee-Jin
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.

Study on Comfortable Room Temperature using Mean Skin Temperature analysis in Sleeping (평균피부온도 분석을 통한 수면시 쾌적 실내 온도조건에 관한 연구)

  • KIm, Dong-Gyu;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • It is necessary to control the room temperature for comfortable and deep sleep during a tropical night. We need to investigate thermal transport and parameter between human and environment for comfortable sleep. Therefore this study is performed to evaluate the comfortable room temperature based on the change of skin temperature under variations in thermal conditions and several reports. Five female subjects of 20~22 years with similar sleeping pattern were participated for the experiment. The subjects arrived in chamber at 9 pm and adapted to thermal circumstances during 2 hours. The sensors was sticked in body for skin temperatures. If subjects fall asleep in chamber, lights off and then sleep during 8 hours.As results, indoor temperature range for comfort sleep was $23.9{\sim}28.4^{\circ}C$ based on comfort mean skin temperature. But considering transition of time, minimum indoor temperature was $21.6^{\circ}C$, $22.9^{\circ}C$, $24.1^{\circ}C$, $23.9^{\circ}C$ and maximum indoor temperature was $28.2^{\circ}C$, $30.1^{\circ}C$.