• Title/Summary/Keyword: Indoor Pollutant

Search Result 140, Processing Time 0.025 seconds

A study on the concentration distribution of CO and $CO_2$ by a form of parking lot in the multiplex use facility (다중이용시설의 주차장 형태에 따른 CO, $CO_2$ 의 농도분포에 관한 연구)

  • Sin, Ji-Won;Kim, Tea-Woo;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.316-321
    • /
    • 2006
  • Multiplex use facility emphasized the importance of indoor air environment because many people using that place. People using parking lot of multiplex use facility in little time, but a pollutant of in indoor air menacing user health. This study measure and analyze the CO, $CO_2$ for better air quality of an indoor parking lot in the multiplex user facility. As a result, two-way opened above ground parking lot is higher numerical value of CO, $CO_2$ than an underground parking lot. And a parking lot of square form is higher numerical value of $CO_2$ than a parking lot of rectangle form.

  • PDF

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

The Study for Adsorption of Indoor Pollutants by Ocher and Diatomite Filter (황토와 다공성 규조토 필터에 의한 실내 오염 물질의 흡착 연구)

  • Kim, Ho-Keun;Irodakhon, Akhmadalieva;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.583-591
    • /
    • 2020
  • Environmental problems have showen over the past decades due to the rapid development of the world economy and the continued growth of the population. Ocher has been widely used for water treatment research, but few studies have been conducted on adsorption of air pollutants using ocher and porous diatomite earth for indoor air purification. In this study, ocher and diatomite earth were sintered with filters to remove indoor air pollutants. The four types of TMA, H2S, NH3 and CH3COOH were used to study the adsorption efficiency of ocher and porous diatomite filters. With the proper use of ocher, diatomite and copper catalysts, indoor air pollutants could be adsorbed. Alkaline substances (TMA and NH3) and acidic substances (H2S and CH3COOH) were able to adsorb at 120 and 90 minutes, respectively.

Development of an Economic Assessment Model for the Selection of Indoor Air Pollutant Low Emission Material for G-SEED (G-SEED용 실내공기 오염물질 저방출 자재 선정을 위한 경제성 평가 모델 개발)

  • Kwon, Seong-Min;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.289-296
    • /
    • 2021
  • The Korean construction industry has been implementing G-SEED, a certification system that evaluates the environmental properties of buildings for the purpose of reducing environmental burdens such as energy and resource consumption and pollutant emissions. Also, creating a pleasant environment in general is one more purpose of G-SEED certification system. However, G-SEED certification in practice is difficult and time consuming due to the complexity of the certification acquisition process coupled with little economic consideration for the materials of each certification item. Therefore, in this study, we present a model for the optimal selection of materials and economic assessment using a genetic algorithm. The development of the model involves building a material database based on life-cycle costing (LCC) targeted at "Application of Indoor Air Pollutant Low Emission Material" from G-SEED. Next, the model was validated using a real non-residential building case study. The result shows an average cost reduction rate of 74.5 % compared with the existing cost. This model is expected to be used as an economically efficient tool in G-SEED.

The Study on the Level of Air Pollution at Four Department Stores in Pusan Area (부산지역 4개 백화점의 공기오염도에 관한 조사연구)

  • Moon, D.H.;Rhee, HW.;Lee, C.U.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

A Study on the Characteristics of Indoor Air Quality in Elevator (엘리베이터 실내공기질의 특성 기초조사)

  • Park, Jeong-Ho;Choo, Yeon-Gyu;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

Indoor and Outdoor $NO_2$ Concentration at Subway Station and Personal $NO_2$ Exposure of Subway Station Workers (지하철역사의 이산화질소 농도와 역무원의 이산화질소 개인폭로량)

  • 손부순;장봉기;박종안;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.134-141
    • /
    • 2000
  • The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.

  • PDF

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul (서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구)

  • Jeon, Jea-Sik;Kim, Mi-Hyung;Lee, Ju-Yeol;Jeon, Myung-Jin;Ryu, In-Cheol;Park, Duck-Shin;Choi, Han-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.