• 제목/요약/키워드: Indoor Particulate Matter

검색결과 114건 처리시간 0.023초

실내 미세먼지 및 소음 모니터링 시스템 설계 및 구현 (Design and Implementation of an Indoor Particulate Matter and Noise Monitoring System)

  • 조현태
    • 대한임베디드공학회논문지
    • /
    • 제17권1호
    • /
    • pp.9-17
    • /
    • 2022
  • As the COVID-19 pandemic situation worsens, the time spent indoors increases, and the exposure to indoor environmental pollution such as indoor air pollution and noise also increases, causing problems such as deterioration of human health, stress, and discord between neighbors. This paper designs and implements a system that measures and monitors indoor air quality and noise, which are representative evaluation criteria of the indoor environment. The system proposed in this paper consists of a particulate matter measurement subsystem that measures and corrects the concentration of particulate matters to monitor indoor air quality, and a noise measurement subsystem that detects changes in sound and converts it to a sound pressure level. The concentration of indoor particulate matters is measured using a laser-based light scattering method, and an error caused by temperature and humidity is compensated in this paper. For indoor noise measurement, the voltage measured through a microphone is basically measured, Fourier transform is performed to classify it by frequency, and then A-weighting is performed to correct loudness equality. Then, the RMS value is obtained, high-frequency noise is removed by performing time-weighting, and then SPL is obtained. Finally, the equivalent noise level for 1 minute and 5 minutes are calculated to show the indoor noise level. In order to classify noise into direct impact sound and air transmission noise, a piezo vibration sensors is mounted to determine the presence or absence of direct impact transmitted through the wall. For performance evaluation, the error of particulate matter measurement is analyzed through TSI's AM510 instrument. and compare the noise error with CEM's noise measurement system.

Relationship between Indoor and Outdoor Particulate Matter Concentrations in Japan

  • Nakai, Satoshi;Tamura, Kenji
    • Asian Journal of Atmospheric Environment
    • /
    • 제2권1호
    • /
    • pp.68-74
    • /
    • 2008
  • We briefly show the results of indoor and personal $PM_{2.5}$ measurements in an epidemiologic study designed to evaluate the health risks of ambient $PM_{2.5}$ in Japan and the relationship between indoor and outdoor PM concentrations. The impact of indoor and outdoor PM pollution on health is described based on one morbidity study. The results of other studies on indoor $PM_{2.5}$ measurements are also described.

Effect of Several Native Moss Plants on Particulate Matter, Volatile Organic Compounds and Air Composition

  • Gong, Gyeong Yeop;Kang, Ji Su;Jeong, Kyeong Jin;Jeong, Jun Ho;Yun, Jae Gill
    • 인간식물환경학회지
    • /
    • 제22권1호
    • /
    • pp.31-38
    • /
    • 2019
  • Experiments were carried out to investigate the effects of mosses on the removal of particulate matter (PM 10) and volatile organic compounds (VOCs) in an indoor space and on the composition of air. For particulate matter removal experiments, 0.2 g mosquitto coil was burned in a glass chamber, where three kinds of mosses (Plagiomnium cuspidatum, Myuroclada maximowiczii, Etodon luridus) were placed. For VOCs removal experiments, 1 mL paint thinner was volatilized in a glass chamber, where Plagiomnium cuspidatum and Myuroclada maximowiczii were used. As a result, it was found that particulate matter was effectively removed by the three mosses, and the removal efficiency of particulate matter increased as the amount of mosses increased. The amount of VOCs was similar to the level in the control when a low amount of mosses (2 and 4 plates) was used. However, the removal efficiency of VOCs was significant when 6 plates of mosses were used. On the other hand, formaldehyde concentration was 40 times more than the control and carbon monoxide 30 times, when 0.2 g of mosquito repellent was completely burned in a glass chamber. Also formaldehyde removal effect was significant when 6 plates of mosses were placed. However, there was no change in the concentration of indoor oxygen, temperature and humidity by moss plants. In conclusion, the moss plants were effective in removing particulate matter and VOCs, and they are expected to be used for indoor decoration and landscape in order to improve indoor air quality in the future.

실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가 (Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter)

  • 양영권;박진철
    • 토지주택연구
    • /
    • 제10권3호
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

조리과정에서 생성된 미세먼지의 크기분포 특성 (Size Distribution Characteristics of Particulate Matter Emitted from Cooking)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제16권1호
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.

도시철도 환경의 미세먼지 오염 현황 (Status of particulate matter pollution in urban railway environments)

  • 김종범;이승복;배귀남
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.303-314
    • /
    • 2018
  • The urban railway system is a convenient public transportation system, as it carries many people without increasing traffic congestion. However, air quality in urban railway environments is worse than ambient air quality due to the internal location of the source of air pollutants and the isolated space. In this paper, characteristics of particulate matter (PM) pollution in urban railway environments are described from the perspective of diurnal variation, chemical composition and source apportionment of PM. PM concentrations in concourse, platform, passenger cabin, and tunnel are summarized through an analysis of 34 journal articles published in Korea and overseas. This information will be helpful in developing effective policies to reduce PM pollution in urban railway environments.

지하역사내 식생바이오필터의 입자상 오염물질 저감특성 연구 (Study on Particulate Pollutant Reduction Characteristics of Vegetation Biofilters in Underground Subway Stations)

  • 김태한;오지은;김미주
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.99-105
    • /
    • 2022
  • Public attention to the indoor environment of underground subway stations, which is a representative multi-use facility, has been increasing along with the increase in indoor activities. In underground stations, fine iron oxide, which affects the health of users, is generated because of the friction between wheels and rails. Among particulate pollutant reduction technologies, plants have been considered as a non-chemical air purification method, and their effects in reducing certain chemical species have been identified in previous studies. The present study aimed to derive the total quantitative and qualitative reduction effects of a bio-filter system comprising air purifying plants, installed in an underground subway station. The experiment proceeded in two ways. First, PM(particulate matter) reduction effect by vegetation biofilter was monitored with the IAQ(indoor air quality) station. In addition, chemical speciation analysis conducted on the samples collected from the experimental and control areas where plants and irrigation using SEM-EDS(scanning electron microscopy-energy dispersive X-ray spectroscopy). This study confirmed the effect of the vegetation bio-filter system in reducing the accumulation of particulate pollutants and transition and other metals that are harmful to the human body.

Particle size distributions and concentrations above radiators in indoor environments: Exploratory results from Xi'an, China

  • Chen, Xi;Li, Angui
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.237-245
    • /
    • 2015
  • Particulate matter in indoor environments has caused public concerns in recent years. The objective of this research is to explore the influence of radiators on particle size distributions and concentrations. The particle size distributions as well as concentrations above radiators and in the adjacent indoor air are monitored in forty-two indoor environments in Xi'an, China. The temperatures, relative humidity and air velocities are also measured. The particle size distributions above radiators at ten locations are analyzed. The results show that the functional difference of indoor environments has little impact on the particle size distributions above radiators. Then the effects of the environmental parameters (particle concentrations in the adjacent indoor air, temperatures, relative humidities and air velocities) on particle concentrations above radiators are assessed by applying multiple linear regression analysis. Three multiple linear regression models are established to predict the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_1$ above radiators.

국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포 (Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea)

  • 김기연
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성 (Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area)

  • 백성옥;송희봉
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF