• 제목/요약/키워드: Indoor Gymnasium

검색결과 20건 처리시간 0.022초

음향시뮬레이션을 이용한 대형 실내체육관의 건축음향성능 개선에 관한 연구 (Architectural Acoustic Performance Renovation of the Large Gymnasium using Acoustic Simulation)

  • 윤재현;김재수
    • 한국주거학회논문집
    • /
    • 제19권4호
    • /
    • pp.41-48
    • /
    • 2008
  • In this study, an analysis is carried out on the acoustic design for an indoor gymnasium scheduled to be built at Buan County, Chonbuk Province. By way of background, the study examines the case of a large-scale indoor gymnasium that has been constructed in the local area of Hangan-myeon. There are many examples whereby this gymnasium could be used not only as a sporting facility for the residents, but also as a multipurpose space for public performances such as leisure activities, lectures, assembling activities, theatre and concerts etc. In order to maximize the functional utilization of such an indoor gymnasium, it is important to simultaneously verify the acoustic capabilities of the space in terms of Definition of both Voice and Music. However, as a large-scaled athletic facility, the building was designed with a high ceiling-height to accommodate its functional characteristics. The space forms a Sound Focus whereby the sound is concentrated at a specific part, and because the vibration of sound is too loud due to its broad volume, acoustic defects arise such as a significant number of Echoes. Using this gymnasium as a precedent, this study proposes an acoustic design based on the drawings of the indoor gymnasium that is scheduled to be built at B County, Chonbuk Province. The gymnasium is equipped with an optimized acoustic condition passing through the Acoustic Simulation Phase. From the results of an Acoustic Simulation, we can design an indoor gymnasium that is equipped with a considerably satisfying and improved acoustic performance compared with the building before it was reformed. It is also considered that the use of such materials can fundamentally reduce construction costs and can improve acoustic performance, at the planning and design stages for similar sporting facilities in the future.

대형(大形) 실내체육관(室內體育館)의 건축음향성능(建築音響性能) 개선(改選)에 관(關)한 연구(硏究) (A Study on the Improvement of Architectural Acoustic Performance in the Large Gymnasium)

  • 윤재현;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.421-426
    • /
    • 2008
  • In case of the large-scaled indoor gymnasium that has been constructed in the local area, there are many instances for the use as multipurpose space where the public performances are possible such as leisure activity, lecture, assembling activity, drama, concert and so on for the resident together with the purpose of sporting facility. In order for utilization to the maximum of the function of such indoor gymnasium, the acoustic capabilities concerned with Definition of both Voice and Music are simultaneously required. However, in case of the large-scaled athletic facility, since it was designed with high ceiling-height in view of its characteristics, it forms a Sound Focus and then the sound is concentrating to the specific part, and because the vibration of sound is too loud due to its broad volume, the acoustic defects such as many Echoes are arising. On such viewpoint, based on the drawing of the indoor gymnasium that is scheduled to be built at B County, Chonbuk Province, this Study has proposed such indoor gymnasium equipped with the optimized acoustic condition passing through Acoustic Simulation Phase. As the result of Acoustic Simulation, we could design the indoor gymnasium that equipped with really satisfying acoustic performance 'after' reformation compared with 'before' reformation, and it is considering that such material could be utilized as the fundamental material that brings a curtailment effect of the construction cost and also enables us to improve the acoustic performance, at the stage of planning and designing for the similar sporting facility in the future.

  • PDF

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

대형 실내체육관 음향성능의 주관적 반응 평가에 관한 연구 (A Study on the Subjective Response Evaluations of Acoustics Performance of the Large Gymnasium)

  • 윤희경;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.53-58
    • /
    • 2003
  • Now days, as the consideration of sound environment is getting important, method of physical measurement such as reverberation time and sound pressure level becomes common. However, such method cant include subjective sensation such as personal emotion and feeling, evaluation. So there is a limitation to make the most optimized sound environment. Therefore, in the present experiment, I improve big indoor gymnasium that has sound defect because of too long reverberation time. After that, I conduct the auditory sense evaluation of human psychological response. From the experiment, I will make research into sound satisfaction rate about the subject space and response of each item. As well as, I will present the result as basic database of sound environment improvement experiment of indoor gymnasium.

  • PDF

실내체육관에서의 공기오염에 관한 연구 (A Study on Air Pollution in Indoor Gymnasiums)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 - (A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy -)

  • 최동호;정성진;석호태
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.67-77
    • /
    • 2007
  • 본 연구에서는 기존 대공간의 난방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 난방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 동절기 대공간의 실내온열환경 실측실험을 비난방시와 난방시로 구분하여 실시하였으며 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 실내열환경을 포괄적으로 검토하였다.

  • PDF

대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 - (A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy -)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회논문집
    • /
    • 제7권6호
    • /
    • pp.91-101
    • /
    • 2007
  • 본 연구에서는 기존 대규모 실내경기장의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인함으로서 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하절기 대공간의 실내온열환경 실측실험을 비냉방시와 냉방시로 구분하여 실시하였으며 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 실내온열환경을 포괄적으로 검토하였다.

  • PDF

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

대공간내 인체발열 미고려시의 하계 온열환경 조사 (A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.3-8
    • /
    • 2008
  • 본 연구에서는 기존 대공간의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하계 대공간의 실내온열환경 실측실험을 실시하여 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 하계 실내온열환경을 포괄적으로 검토하였다.

  • PDF

실내체육관의 신재생에너지 공급의무비율에 따른 시스템 최적화 연구 (A Study on System Optimization according to the Supply Obligations Rate of New and Renewable Energy at an Indoor Gymnasium)

  • 박윤하;김윤호;원안나;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.51-60
    • /
    • 2015
  • In statutes on the promotion of distribution of new and renewable energy, which were revised in 2014, daylight system and fuel cell were added in addition to existing new and renewable energy sources. This study, therefore, aimed at setting up targets for the introduction of daylight system and analyzing the installation rate of new and renewable energy which can be provided by daylight system for the aggressive use of daylight system, thereby deducting the optimal combination ratio with other new and renewable energy sources. The results of the study are as follows. First, when a prism-shaped daylight system was installed to a round indoor gymnasium among domestic indoor gymnasiums, out of a supply obligations allotment rate of 15% of new and renewable energy, the rate of daylight system was basically set at 2.5%. Second, therefore, with daylight system coming first, the lacked supply obligations rate was taken up by solar photovoltaic, solar heat and geothermal heat. In addition, using the KRESS Program, economic, technical, environmental and complexity evaluations for the upper 5% was made, deducting the optimal ratio of the system. The results produced the following optimal combination ratios: solar photovoltaic (83.3%) in economic evaluation, solar heat (8.3%) and geothermal heat (75%) in technical evaluation, solar photovoltaic (83.3%) in environmental evaluation, and solar photovoltaic (83.3%, the same as in economic evaluation) in complexity evaluation.