• Title/Summary/Keyword: Indoor Environment Monitoring

Search Result 150, Processing Time 0.019 seconds

A Field Survey of Thermal Comfort in Office Building with Thermal Environment Standard (온열환경기준에 따른 여름철 사무실의 열쾌적성 평가)

  • Kong, Hyo-Joo;Yun, Geun-Young;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.37-42
    • /
    • 2011
  • This study aims to analyze the field survey of thermal comfort in office building with national thermal environment standard. Internal and external temperatures were measured at ten minute intervals and compared in accordance with the national standard for thermal environment. Sixty two workers filled in the questionnaire survey forms five times a day for 40 days. Field monitoring of offices in Seoul, Korea were conducted from 20 July to 28 August. Result for the comfort temperature was set a $26.30^{\circ}C$. This indicates that the 26 degree is reliable for the Korean standard. Indoor temperature standard can reduce energy use by air-conditioned buildings and the temperature would be offer comfort to occupants.

Indoor and Personal Exposure to Carbon Monoxide in Homes (一酸化炭素의 家庭內 濃度 및 主婦의 個人曝露濃度에 關한 調査硏究)

  • 김윤신;손부순;유행행웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 1990
  • A pilot field study was conducted to measure indoor and personal exposure to carbon monoxide (CO) levels using personal monitors from January to February in 1989. The principal objectives of the study was to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. The mean CO concentrations in kitchen and in bedroom were 23.4 and 11.9 ppm, respectively, while mean concentration of personal CO exposure was 18.9 ppm. It was found that the mean CO concentrations in kitchen exceeded 20 ppm of the Korea ambient CO standard(8-hr average) not to be exceeded more than three times per year. The results suggest that indoor CO levels in Korean houses appear to be affected by use of coal briquette for heating any cooking.

  • PDF

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

Classification of Pollution Patterns in High School Classrooms using Disjoint Principal Component Analysis (분산주성분 분석을 이용한 고등학교교실 내 오염패턴분류에 관한 연구)

  • Jang, Choul-Soon;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.808-820
    • /
    • 2006
  • In regard to indoor air quality patterns, the government introduced various polices that were about managing and monitoring quality of indoor air as a major assignment, and also executed 'Indoor Air Quality Management Act' which was presented in the May, 2004. However, among the multi-usage facilities controlled by the Act, the school was not included yet. This study goal was to investigate PM 10 pollution patterns of the high school classrooms using a pattern recognition method based on cluster analysis and disjoint principal component analysis, and further to survey levels of inorganic elements in May, June, and September, 2004. A hierarchical clustering method was examined to obtain possible objects in pseudo homogeneous sample classes by transformation raw data and by applying various distance. Following the analysis, the disjoint principal component analysis was used to define homogeneous sample class after deleting outliers. Then three homogeneous Patterns were obtained as follows: the first class had been separated and objects in the class were considered to be sampled under semi-open condition. This class had high concentration of Ca, Fe, Mg, K, Al, and Na which are related with a soil and a chalk compounds. The second class was obtained in which objects were sampled while working air-conditioners and was identified low concentration of PM 10 and elements. Objects in the last class were assigned during rainy day. A chalk, soil element and various types of anthropogenic sources including combustions and industrial influenced the third class. This methodology was thought to be helpful enough to classify indoor air quality patterns and indoor environmental categories when controlling an indoor air quality.

Three Dimensional Indoor Location Tracking Viewer

  • Yang, Chi-Shian;Jung, Sang-Joong;Chung, Wan-Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.1
    • /
    • pp.108-118
    • /
    • 2009
  • In this paper we develop an indoor location tracking system and its 3D tracking monitoring viewer, viz., 3D Navigation Viewer (3DNV). We focus on the integration of an indoor location tracking system with the Virtual Reality Modeling Language (VRML), to facilitate a representation of the user's spatial information in virtual indoor environments that is synchronized with the physical location environment. The developed indoor location tracking system employs beacons as active transmitters, and a listener as a passive receiver. The distance information calculated from the difference speeds of RF and Ultrasonic signals is exploited, to determine the user's physical location. This is essential in supporting third parties like doctors and caregivers in identifying the activities and status of a particular individual via 3DNV. 3DNV serves as a unified user interface for an indoor location tracking system, showing the viewpoint and position of the target in virtual indoor environments. It was implemented using VRML, to provide an actual real time visualization of the target's spatial information.

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

Visible Light Communication Based Wide Range Indoor Fine Particulate Matter Monitoring System (가시광통신 기반 광역 실내 초미세먼지 모니터링 시스템)

  • Shakil, Sejan Mohammad Abrar;An, Jinyoung;Han, Daehyun;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Fine particulate matter known as PM 2.5 refers to the atmospheric particulate matter that has a diameter less than 2.5 micrometer identified as dangerous element for human health and its concentration can provide us a clear picture about air dust concentration. Humans stay indoor almost 90% of their life time and also there is no official indoor dust concentration data, so our study is focused on measuring the indoor air quality. Indoor dust data monitoring is very important in hospital environments beside that other places can also be considered for monitoring like classrooms, cements factories, computer server rooms, petrochemical storage etc. In this paper, visible light communication system is proposed by Manchester encoding technique for electromagnetic interference (EMI)-free indoor dust monitoring. Important indoor environment information like dust concentration is transferred by visible light channel in wide range. An average voltage-tracking technique is utilized for robust light detection to eliminate ambient light and low-frequency noise. The incoming light is recognized by a photo diode and are simultaneously processed by a receiver micro-controller. We can monitor indoor air quality in real-time and can take necessary action according to the result.

The Research on the Indoor Temperature and Humidity Control of Green Roof by Solid Growing Medium in Summer (고형화된 식생기반재를 활용한 여름철 옥상녹화의 실내 온·습도 조절효과 연구)

  • Lee, Hyun-Jung;Yeom, Dongwoo;Lee, Kyu-In
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.93-99
    • /
    • 2015
  • Purpose: Various studies on the soil-based green roof systems have been conducted, and a lot of green roof systems were developed. A growing medium board is one of them which was developed for better application and maintenance, however the effect and performance of this material need to be verified. On this background, the purpose of this study is to prove cooling load reduction of green roof by monitoring experiment on the full-scale mock-ups. Method: To do this, Solid growing medium boards were installed on the mock-ups, and indoor temperature and humidity were monitored and analyzed. Result: As a results, the green roof with solid growing medium board were verified effective for controlling indoor temperature in summer.

Hybrid Indoor Position Estimation using K-NN and MinMax

  • Subhan, Fazli;Ahmed, Shakeel;Haider, Sajjad;Saleem, Sajid;Khan, Asfandyar;Ahmed, Salman;Numan, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4408-4428
    • /
    • 2019
  • Due to the rapid advancement in smart phones, numerous new specifications are developed for variety of applications ranging from health monitoring to navigations and tracking. The word indoor navigation means location identification, however, where GPS signals are not available, accurate indoor localization is a challenging task due to variation in the received signals which directly affect distance estimation process. This paper proposes a hybrid approach which integrates fingerprinting based K-Nearest Neighbors (K-NN) and lateration based MinMax position estimation technique. The novel idea behind this hybrid approach is to use Euclidian distance formulation for distance estimates instead of indoor radio channel modeling which is used to convert the received signal to distance estimates. Due to unpredictable behavior of the received signal, modeling indoor environment for distance estimates is a challenging task which ultimately results in distance estimation error and hence affects position estimation process. Our proposed idea is indoor position estimation technique using Bluetooth enabled smart phones which is independent of the radio channels. Experimental results conclude that, our proposed hybrid approach performs better in terms of mean error compared to Trilateration, MinMax, K-NN, and existing Hybrid approach.

Comparative Evaluation of Gravimetric Measurement Methods for Suspended Particles in Indoor and Outdoor Air (실내.외 공기 중 부유먼지 측정방법 상호간의 비교평가 - 중량법을 대상으로)

  • 백성옥;박지혜;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.285-295
    • /
    • 2002
  • In this study, several types of gravimetric methods (such as high, medium, low, and ultra low volume sampling methods) were applied to determine suspended particulate matter concentrations in both ambient and indoor environments. Comparative evaluations were undertaken with SPM data obtained using a variety of samplers (TSP, PM10, and PM4.0) at different sampling flow rates. Correlation coefficients between TSP and PM10 concentrations measured at different flow rates fell in the range of 0.73∼0.94 (n=40). In addition, correlation coefficients for PM concentrations measured by different TSP samplers were in the range of 0.90∼0.95 (n=36 or n=38), while 0.77∼0.91 (n=38) for PM10 samplers. Correlation analysis was also conducted on indoor monitoring data that were measured using ultra-low-volume samplers at both different or identical flow rates. The correlation coefficients were in the range of 0.98∼0.99 (n=38) between TSP and TSP and 0.92∼0.94 (n=38) between TSP and PM10. The mean ratio for high volume PM10 to TSP concentration that was monitored at identical flow rates in the ambient air appeared to be 0.72. The mean ratios of PM10 to TSP and PM4.0 to TSP observed with identical flow rates at indoor environments were 0.47 and 0.40. The results of this study may provide empirical information concerning the compatability of aerosol data obtained by gravimetric sampling methods at different flow rates.