• 제목/요약/키워드: Indoor Environment Measurement Data

검색결과 87건 처리시간 0.026초

교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구) (Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement))

  • 조민관
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

현장측정을 통한 대형 할인매장의 실내환경 평가 (Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores)

  • 박병윤;정용호;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of $CO_2$, CO gas and TSP were measured and evaluated. In each case of $CO_2$, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from $18^{\circ}C$ to $28^{\circ}C$ according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

서울지역 건축물의 환경적 특성에 따른 실내 라돈농도 변화 (The Variation Characteristics of Indoor Radon Concentration from Buildings with Different Environment, Seoul)

  • 전재식;이지영;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.692-702
    • /
    • 2011
  • For more effective indoor radon reduction policy and technique, we researched radon data analysis for some buildings in Seoul. Those buildings were categorized as dwelling, underground and office space and the variations of radon concentration and its sources were evaluated. The variations of radon concentrations of indoor space of buildings for a day were patterned specifically by dwelling habits and different environment. As for the new built apartments which were not yet moved in, their indoor radon concentrations were showed more than 3 times after applying interior assembly, and were 5 times higher than ones of rather old residences. As for the subway stations, the radon concentrations during off-run times were about 15% higher than run-times. 10% of radon seemed to be reduced by installation of platform screen doors. As for office space, radon concentrations during working hours were about 2.5 times higher than non-working hours. Plaster board are expected as a main source of radon for them. By radon measurement method for long-term, its data can be over estimated because it covers non-active time in office or public space. Therefore combination of short and long-term measurement method is required for effective and economic reduction. Furthermore importance of ventilation is requested as public information service for all dwelling space. And also standardization for radium content or radiation of radon is necessary.

전통주택의 하절기 실내 온열감 평가에 관한 연구 (A Study on the Thermal Sensation Vote of the Traditional Housing in Summer)

  • 강상우;전지현;신용규;민병철;국찬
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.488-491
    • /
    • 2006
  • There is a principle of Korean Traditional Housing to be adapted for the nature using adaptable shapes to regional climate and easily available materials from the region then these environmentally friendly characteristics keep indoor environment from climate changes. These environmentally friendly characteristics to control indoor environment are very available for contemporary housing in that current issues, housing amenity and wellbeing, have basic goals same with what Korean Traditional Housing has. Therefore, this study begins to suggest fundamental data on indoor thermal environment control elements of Korean Traditional Housing to adapt those into contemporary housing through measurement of indoor thermal environment elements and evaluation on thermal sensation vote for Korean traditional housing. There was 24 hours measurement for indoor and outdoor thermal environmental elements to figure out competence to control indoor thermal environment of Korean Traditional Housing in summer. And subjective tests with 11 subjects was held in the morning, afternoon and night at intervals of 3${\sim}$4 hours to evaluate feeling and amenity for temperature and humidity of users.

  • PDF

울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향 (The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan)

  • 유복희
    • 한국주거학회논문집
    • /
    • 제21권3호
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

실내 건축 마감자재의 공기오염물질 방출량 분석 (Measurement of Air Contaminants Emission from Interior Finish Material)

  • 김윤덕;임수영
    • 교육시설
    • /
    • 제14권1호
    • /
    • pp.58-65
    • /
    • 2007
  • For the moderns who spend more than 80% of the time inside a building, interior environment became important since it directly affects their health. Recently as noxiousness of the air contaminants of the interior space stood out as well as the above trend, the Ministry of Environment enacted a lawto maintain the interior air quality at certain level of standard in the multi use facility and newly constructed apartment. To make the indoor air clean, removal technology of various contaminants should be developed and interior materials with chemical treatment should be restrained. In other words, selection of interior finish affects indoor air quality from the initial design stage to the construction stage. However, only limited contaminants emission data of building materials are supplied by related companies. There is no average contaminants emission data for overall materials. Moreover, high cost and equipments for one time measurement of VOCs emission of interior finish are the obstacles of active research and data measurement. Therefore, this paper searched the current condition of average VOCs & HCHO emission of various interior finish based on the study requested to research center from the building material company through Stands Test Method for Indoor Air Quality.

UWB 레이더와 실내 환경 측정 센서를 이용한 랜덤 포레스트 모델의 재실활동 유형 감지 (Activity Type Detection Of Random Forest Model Using UWB Radar And Indoor Environmental Measurement Sensor)

  • 박진수;정지성;양철승;이정기
    • 문화기술의 융합
    • /
    • 제8권6호
    • /
    • pp.899-904
    • /
    • 2022
  • 본 세계적으로 출생률이 줄고 기대 수명이 늘어나 고령화 사회가 되어감에 따라 고령 인구의 건강 관리를 위한 시스템이 필요하다. 그 중 실내 건강 관리를 위한 스마트 홈 캐어 서비스를 위해서는 재실 여부 및 활동 유형에 관한 다양한 연구가 수행되고 있다. 본 논문에서는 스마트 홈 캐어 서비스를 위해 실내 온습도, CO2, 미세먼지 값과UWB 레이더 측위를 통해 재실 여부 뿐만 아니라 활동 유형을 분류하는 랜덤 포레스트 모델을 제안한다. 실험은 실내 온습도, CO2, 미세먼지를 측정하는 센서 3개와 UWB Radar 2개를 사용하여 2초 간격으로 실내 환경 및 재실자의 측위 데이터를 측정한다. 측정된 데이터는 이상치와 결측치를 보정 처리한 후 80%의 트레이닝 셋 데이터와 20%의 테스트 셋 데이터로 이분하며 랜덤 포레스트 모델을 적용하여 중요도 상위 변수 목록, 정확도, 민감도, 특이도, T1 스코어를 평가한다.

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

2.45 GHz 대역 실내 무선 환경 측정 (Measurement of the Indoor Wireless Environment at 2.45 GHz)

  • 황재호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.1005-1008
    • /
    • 2006
  • 본 논문은 2.4 GHz대역 블루투스 시스템 및 무선랜 시스템을 효과적으로 구축하기 위해 필요한 다양한 실내 전파환경 데이터의 제공을 목적으로 한다. 측정 방법으로는 안테나의 송수신 방사특성을 측정하는 장비를 옥내에 설치하고, 전파경로에 각종 재질의 구조물을 설치하여 방사특성을 측정한다. 두께 25cm의 일반 시멘트벽을 투과할 경우의 감쇄를 측정 한 결과, 도달거리 1m 에서 약 $1\sim3dB$정도의 감쇄가 생김을 알 수 있었다. 또한 철골벽의 경우 철골 구조와 수평한 편파를 사용할 경우에는 감쇄가 증가하지만, 수직한 편파를 사용할 경우 철곡의 영향이 거의 없음을 알 수 있다.

  • PDF

煖房器具를 사용하는 室內空氣중의 벤조(a) 피렌 成分濃度에 관한 硏究 (Benzo(a) pyrene Level in Indoor Environment due to the Use of Unvented Heating Facilities)

  • 董宗仁
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.65-73
    • /
    • 1987
  • Indoor air pollution problems, in fact, have been neglected due to the unawareness of its seriousness and the lack of accumulated data. Recently, some movement of research and regulations, however, have been made for several indoor air pollutants. In this study, one of the carcinogenic polynuclear aromatic hyrocarbon, Benzo(a) pyrene in indoor airborne particulate, was measured and analyzed to estimate emission strength of BaP from an unvented kerosene heater and to know its level in indoor environment with use of a kerosene heater and a wood-burning fireplace. By the measurement of BaP level in a dark room with air exchange rate of app. 3.0, BaP emission strength of a kerosene heater (11,000Btu/hr) was estimated to be 326.6ng/hr (or 29.7 ng/$10^3$ Btu). With 4-hr operation a day of the kerosene heater in an apartment, the BaP level became 2.97ng/m$^3$ from 0.27ng/m$^3$ of background level. The operation of a wood-burning fireplace app. 2hr a day, on the other hand, increased the BaP level from 0.16ng/m$^3$ of background to 3.53ng/m$^3$. So proper ventilation must be considered seriously when unvented heating facilities are used in indoor environment.

  • PDF