• 제목/요약/키워드: Indoor Comfort

검색결과 353건 처리시간 0.027초

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

여름철 도시의 일상생활에서 경험하는 환경온도와 온냉감 평가 (24 hours' Exposed Temperature and Thermal Comfort in Summer)

  • 전정윤;이민정
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.51-56
    • /
    • 2003
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces with temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects were wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Subjects controls their micro climate like this. Most of them(84.6%) get weather information. Fashion(46.2%) and weather(30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Temperature fluctuation which subjects were exposed for 24 hours were from 15.6$^{\circ}C$ to 33.8$^{\circ}C$ and average fluctuation was 9.02$^{\circ}C$. The median value of experienced temperature were 26-26.5$^{\circ}C$ and average temperature was 26.18$^{\circ}C$. They experienced cold shock of 3.96 times in a day.

하계 및 동계 실내 온열 환경 특성과 쾌적성 평가에 대한 연구 (A Study on Characteristics of Indoor Thermal Environment and Comfort Evaluation in Summer and Winter)

  • 고경태;박종일;김경훈
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.88-93
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physical responses for men in summer and winter indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart rate(Electrocardiogram, ECG), Electroencephalo gram(EEG) were examined. We found that comfort of people was achieved at SET*. 24.7$^{\circ}C$, -0.82${\alpha}$-wave) both in summer and in winter.

  • PDF

여름철 실내외 온도차에 따른 인체의 온열쾌적성 평가 (Evaluation of Thermal Comfort on Temperature Differences between Outdoor and Indoor Thermal Conditions in Summer)

  • 금종수;김동규;최광환;이낙범;임재중;최호선;배동석
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.890-896
    • /
    • 2002
  • Purpose of this study is to clarify the evaluation of thermal comfort based on temperature differences between outdoor and indoor thermal conditions in summer. The experiments were performed to evaluate temperature difference between indoor and outdoor thermal conditions (29, 31, $33^{\circ}$) by physiological and psychological responses of human. According to physiological responses, TSV (thermal sensation vote) and CSV (comfort sensation vote) and psychological responses, ECG (electrocardiogram), MST (mean skin temperature) of human, it was clear that the optimum temperature difference is about $5^{\circ})\;and\;7^{\circ}$).

PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석 (Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

실측을 통한 동절기 전통가옥의 실내온열환경 분석 (The Analysis of Indoor Thermal Environment at the Korean Traditional House in the Winter)

  • 황효근;임종연;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.324-329
    • /
    • 2008
  • Recently with the demand of well-being is increased, the demand for indoor thermal environment and air quality is increased. According to this circumstance, many people in Korea note the traditional architecture that is made by natural materials, such as a soil, stone and wood. However, few researches regarding the indoor thermal environmental characteristics of the Korean traditional houses is reported. In this study we analyzed the indoor thermal environment for Han-ok through field measurement. Moreover, based on the field measurement results. indoor thermal comfort in Han-ok is analyzed.

  • PDF

Comparative Analysis of Indoor Mixture Gas Patterns and Reference Single Gas Patterns Obtained from E-Nose for Indoor Air Quality Monitoring

  • Choi, Jang Sik;Yu, Joon Boo;Jeon, Jin Young;Lee, Sang Hun;Kim, Jae Hong;Park, Jang Pyo;Jeong, Yong Won;Byun, Hyung Gi
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.227-231
    • /
    • 2018
  • Indoor air pollution has become a serious issue, affecting the health and comfort of building occupants. Volatile organic compounds (VOCs) are among the most common indoor contaminants, and are released from numerous indoor emission sources. Among the VOCs, formaldehyde and toluene are toxic chemicals at low levels and are frequently detected indoors. Exposure to formaldehyde and toluene can irritate sensitive tissue and may increase the risk of cancer. Therefore, monitoring formaldehyde and toluene is critical for the health and comfort of residents. In addition, as human indoor activities can generate VOC gases, analysis of their influence on VOCs is needed. In this study, we compared electronic nose (E-Nose) data for formaldehyde and toluene with E-Nose data for indoor mixture gas with consideration for human indoor activities.

실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구 (A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC)

  • 윤성현;박준용;손덕영;최윤호;박경석
    • 대한기계학회논문집A
    • /
    • 제38권9호
    • /
    • pp.979-988
    • /
    • 2014
  • 자동차를 이용하는 시간이 늘어남에 따라 자동차 실내의 온열쾌적성에 대한 관심이 급증하고 있다. 그러나 아직까진 실제 자동차 중에서 공조시스템의 냉방성능은 자동차 제조사별로 온열쾌적성 지표를 통해 평가되지 않고, 실내의 공기 속도와 온도 등 열환경 기준에 의해 평가되고 있다. 또한 차 실내의 온열쾌적성을 수치해석으로 평가하는 경우 타당한 결과를 도출할 수 있는 수치기법에 대한 기준이 확립되지 않은 상황이다. 본 연구에서는 외부 열원을 모사하기 위하여 태양광선 추적모델을 사용하고, 공조시스템 작동 후 20 분까지 다양한 매개변수(공조시스템의 작동모드와 작동풍량, 인체모델 탑승조건)에 대한 자동차 실내의 온열쾌적성 평가를 수행하였다. 이를 통해 자동차 실내의 온열쾌적성 지표를 예측할 수 있는 평가모델을 도출하였다.

Investigation of school building microclimate using advanced energy equipment: Case study

  • Alwetaishi, Mamdooh;Alzaed, Ali;Sonetti, Giulia;Shrahily, Raid;Jalil, Latif
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.10-20
    • /
    • 2018
  • Buildings are responsible of major energy consumption globally. In addition, they are linked to thermal comfort. The need to provide comfort becomes more crucial in schools as they are the place where students learn, and develop their skills. This research aims to investigate the energy responsiveness of new and traditional school building design, where major variation in form, amount of external walls and glazing are different. The research focused on indoor microclimate condition of selected schools in the city of Jeddah where the climate is hot and humid using advanced tools for monitoring. The research uses advanced energy equipment to measure several aspects such as floor temperature, roof temperature, globe temperature and other factors which can lead to predictable thermal comfort of users. The findings suggest that a larger area of glazing shielded from sunlight has a greater influence on both indoor condition and general thermal sensation. The finding also suggests that the glazing ratio is a major contributor on indoor thermal pattern which can result in an increase in temperature profile between from $7-10^{\circ}C$. The findings of this research can assist in the improvement in the design of the prototype school building in hot and humid climate.