• 제목/요약/키워드: Indoor Air Temperature

검색결과 667건 처리시간 0.033초

좌석시트 공조조건에 따른 착석자의 심리 및 생리적 반응 (Psychological and Physiological Responses of Occupants Caused by Types of Seat Air Conditioning)

  • 김보성;곽승현;서상혁;민병찬
    • 산업경영시스템학회지
    • /
    • 제38권3호
    • /
    • pp.14-20
    • /
    • 2015
  • It is important to understand psychological and physiological responses of occupants who seated in a chair in order to shape a comfortable indoor official environment. So it is needed to find out optimal seated conditions. The purpose of this study was to explore optimal condition of seat air conditioning control based on psychological or subjective responses (perceived temperature and comfort sensation) and physiological responses (heartrate variability; HRV). To do this, experimental conditions were designed by the difference of indoor temperature and seat air conditioning temperature. In the experiment 1, seven experimental conditions were designed with one control condition which was not used seat air conditioning system, and six experimental conditions which the difference of indoor temperature and seat air conditioning temperature ($-1^{\circ}C{\sim}-6^{\circ}C$). In the experiment 2, four experimental conditions were designed with one control condition and three experimental conditions ($-3^{\circ}C{\sim}-5^{\circ}C$). In addition, participants' psychological or subjective response was measured by CSV (comfort sensation vote) and PTS (perceived temperature sensitivity) as a psychological or subjective response, and heartrate variability was measured as a physiological response. As a result, in the experiment 1, it was reported that the optimal conditions of seat air conditioning control based on participants' psychological or subjective comfort were from $-3^{\circ}C$ to $-5^{\circ}C$ experimental conditions. In addition, in the experiment 2, it was reported that the optimal condition of seat air conditioning control based on participants' physiological comfort was $-4^{\circ}C$ experimental condition. These results suggested that seat air conditioning could affected to comfort sensation of occupants in an appropriate range, rather than unconditionally.

동시냉난방 열펌프 시스템의 냉방전용 및 냉방주체 운전모드에서의 실내기온 변화에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Cooling-only and Cooling-main Operation Mode with the Variation of the Indoor Air Temperature)

  • 안재환;주영주;강훈;정현준;김용찬;최종민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2165-2170
    • /
    • 2008
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Therefore, the development of a multi-heat pump which can cover heating and cooling simultaneously for each indoor unit is required. In this study, the characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-only and cooling-main operating mode was investigated experimentally with a variation of indoor air dry bulb temperature which is from $21^{\circ}C$ to $35^{\circ}C$. EEV opening was adjusted from 20% to 24% during the tests. When the indoor air temperature varied, the performance in the cooling-only mode was more sensitive to the temperature than in the cooling-main mode. The total capacity and COP were increased by 53.8% and 48.1%, respectively, in the cooling-main, while those were increased by 19.6% and 19.3% in the cooling-only mode. The performance differences between the two operating modes became larger at lower temperatures, especially for the COP.

  • PDF

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

돔경기장의 공조방식에 따른 겨울철 열환경 분석 (The Analysis of Indoor Thermal Environment for Air Condition System in Dome Stadium)

  • 석호태;양정훈;채문병
    • 한국공간구조학회논문집
    • /
    • 제9권2호
    • /
    • pp.53-63
    • /
    • 2009
  • 본 연구에서는 국내 돔경기장을 해석대상공간으로 선정하여 기존 공조방식과 국외 돔경기장에서 사용한 공조방식을 적용하여 겨울철 실내기류 및 온도분포를 분석하고, 열고온층을 해소하기 위한 방안으로 설치된 기류유인팬의 적절성을 검토하였다.

  • PDF

매크로 모델에 의한 실내온열환경 검토 (An Analysis of Indoor Thermal Environment by Macro Model)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2008
  • It is known that slab thermal storage which uses concrete slab as thermal material is effective in the load leveling and using the nighttime electric power. The temperature distribution is not constant in plenum in thermal storage time by beams, ducts such as several factor. It is considered that this fact will effect on efficiency of thermal storage and indoor thermal environment. The purpose of this paper is to examine the thermal environment inside plenum. A macro model was made for the analysis of indoor thermal environment as the first step. The flow rate distribution and temperature distribution of object room model was examined by use of basic equations such as airflow by the pressure difference between unit cells, heat flow by air and heat transfer.

  • PDF

A Study on the Improvement of Comfortable Living Environment by Using real-time Sensors

  • KIM, Chang-Mo;KIM, Ik-Soo;SHIN, Deok-Young;LEE, Hee-Sun;KWON, Seung-Mi;SHIN, Jin-Ho;SHIN, YongSeung
    • 웰빙융합연구
    • /
    • 제5권4호
    • /
    • pp.19-31
    • /
    • 2022
  • Purpose: This study was conducted to identify indoor air quality in various living spaces using sensors that can measure noise, vibration, fine dust, and odor in real time and to propose optimal indoor air quality maintenance management using Internet of Things(IoT). Research design, data and methodology: Using real-time sensors to monitor physical factors and environmental air pollutants that affect the comfort of the residential environment, Noise, Vibration, Atmospheric Pressure, Blue Light, Formaldehyde, Hydrogen Sulfide, Illumination, Temperature, Ozone, PM10, Aldehyde, Amine, LVOCs and TVOCs were measured. It were measured every 1 seconds from 4 offices and 4 stores on a small scale from November 2018 to January 2019. Results: The difference between illuminance and blue light for each measuring point was found to depend on lighting time, and the ratio of blue light in total illumination was 0.358 ~ 0.393. Formaldehyde and hydrogen sulphide were found to be higher than those that temporarily attract people in an indoor office space that is constantly active, requiring office air ventilation. The noise was found to be 50dB higher than the office WHO recommendation noise level of 35 ~ 40dB. The most important factors for indoor environmental quality were temperature> humidity> illumination> blue light in turn. Conclusions: Various factors that determine the comfort of indoor living space can be measured with real-time sensors. Further, it is judged that the use of IoT can help maintain indoor air quality comfortably.

도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로- (Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants -)

  • 백성옥;김윤신
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

실내 공기의 다성분 측정시스템 개발에 관한 연구 (Measurement system of multi-components in indoor air quality)

  • 김보환;이진하;김태진
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.125-130
    • /
    • 2005
  • Six modules composed of individual sensors and circuit systems for oxygen, temperature, humidity, volatile organic compounds, dust, carbon dioxide, in the indoor air quality control were examined to see their individual performances. Experimental results showed that all the six modules were in good linearity with individual concentration variations

운전조건에 따른 전열교환기의 성능특성 연구 (A Study on the Characteristics of Total Heat Exchanger under Various Conditions)

  • 배철호;임영헌;드래바굴노라;박지열;곽경민;주의성;김영생;김지용
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

여름철 실내외 온도차에 따른 인체의 온열쾌적성 평가 (Evaluation of Thermal Comfort on Temperature Differences between Outdoor and Indoor Thermal Conditions in Summer)

  • 금종수;김동규;최광환;이낙범;임재중;최호선;배동석
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.890-896
    • /
    • 2002
  • Purpose of this study is to clarify the evaluation of thermal comfort based on temperature differences between outdoor and indoor thermal conditions in summer. The experiments were performed to evaluate temperature difference between indoor and outdoor thermal conditions (29, 31, $33^{\circ}$) by physiological and psychological responses of human. According to physiological responses, TSV (thermal sensation vote) and CSV (comfort sensation vote) and psychological responses, ECG (electrocardiogram), MST (mean skin temperature) of human, it was clear that the optimum temperature difference is about $5^{\circ})\;and\;7^{\circ}$).