• 제목/요약/키워드: Indoor Air Pollution

검색결과 434건 처리시간 0.022초

실내오염물질방출저감을 위한 주요건축자재의 시공기술에 관한 연구 (A study on the construction technology for major building material to reduce indoor air pollution)

  • 허정용;최창호;안형준;이윤규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.143-148
    • /
    • 2007
  • Recently indoor air pollution caused by exposing hazardous chemicals (VOCs, formaldehyde) due to undiscriminated use of new construction materials and air-tightness to save energy is becoming a big issue. We have developed technologies to estimate the amounts of contaminants from constructions materials and method. We have further developed construction technologies to reduce and characterize these contaminants. The developed technologies were then refined to eliminate defects through considering field applicability.

  • PDF

Indoor exposure to hazardous air pollutants and volatile organic compounds in low-income houses in Lagos, Nigeria

  • Luqmon, Azeez;Musa, Olaogun;Mariam, Adeoye;Abdulazeez, Lawal;Babatunde, Agbaogun;Ibrahim, Abdulsalami;Adija, Majolagbe
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.277-288
    • /
    • 2012
  • This study investigated exposure to air pollutants in rooms in low-income houses at Shomolu (R1), Mafoluku (R2) and Mushin (R3) in Lagos state. The concentrations of most measured exceeded limits of Illinois Department of Public Health (IDPH) for indoor air quality. Air quality index (AQI) in rooms studied was unhealthy for sensitive people in terms of CO, unhealthy in terms of $SO_2$ and very unhealthy in terms of $NO_2$ while moderate air quality was obtained in terms of $PM_{10}$ in most rooms. High concentrations of carbontetrachloride, formaldehyde and xylene measured could have been responsible for some of the health complaints of the occupants. Factor analysis shows that cooking with kerosene, use of gasoline generator and insecticide were the major contributors to indoor air pollution in these rooms. Therefore, there is need to urgently tackle poverty as all affected by these pollutants were poor who live in substandard houses without kitchens.

실내공기중의 휘발성유기화합물 농도변화에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in the Apartment House)

  • 이윤규
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성 (Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement)

  • 최병철;박채울;경인수;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF

실내 라돈오염 해석을 위한 2구역 모델의 민감도 및 불확실성 분석 (Sensitivity and Uncertainty Analysis of Two-Compartment Model for the Indoor Radon Pollution)

  • 유동한;이한수;김상준;양지원
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.327-334
    • /
    • 2002
  • The work presents sensitivity and uncertainty analysis of 2-compartment model for the evaluation of indoor radon pollution in a house. Effort on the development of such model is directed towards the prediction of the generation and transfer of radon in indoor air released from groundwater. The model is used to estimate a quantitative daily human exposure through inhalation of such radon based on exposure scenarios. However, prediction from the model has uncertainty propagated from uncertainties in model parameters. In order to assess how model predictions are affected by the uncertainties of model inputs, the study performs a quantitative uncertainty analysis in conjunction with the developed model. An importance analysis is performed to rank input parameters with respect to their contribution to model prediction based on the uncertainty analysis. The results obtained from this study would be used to the evaluation of human risk by inhalation associated with the indoor pollution by radon released from groundwater.

선형엑츄에이터를 이용한 실내 공기질 개선 시스템에 대한 연구 (A Study on Indoor Air-quality Improvement System Using Actuator)

  • 서도원;윤근영
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.183-190
    • /
    • 2021
  • 본 논문은 실내 공기질 개선을 위한 스마트 공기청정 시스템 구현 및 구동에 관한 연구이다. 최근 다양한 환경적 요인으로 인해 실내 공기질 오염에 따른 문제가 심각해지고 있다. 본 연구에서는 이와 같은 실내 공기질 오염의 문제점을 개선하기 위해, IoT 센서를 활용한 스마트 공기청정 시스템을 구현하고자 한다. 특히 공기질 오염도를 실시간으로 측정하고, 오염도에 따라 서로 다른 공기 정화 경로를 가변시켜 줄 수 있는 시스템을 제안하였다. 이를 통해 효율적인 공기질 개선 및 필터의 수명 연장, 시스템 에너지 저감 등을 검토하였다. 또한 실내 공기질 개선 시스템에 대한 기능을 구현하기 위해 주요 부품을 선정하였고, 시제품을 제작하여 동작성을 확인하였다. 최종적으로 선형엑츄에이터를 활용한 실내 공기질 개선 시스템의 구현을 통해, 공기질 개선에 대한 효용성을 검토하였다.

다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구 (A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes)

  • 안광훈;권종원;김규식;김희식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가 (Evaluation of Pollutants Emissions according to the Selling Store in Department Store)

  • 왕형석;황준석;장성진;김수민
    • 한국가구학회지
    • /
    • 제26권1호
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).