• Title/Summary/Keyword: Indoor Air Pollution

Search Result 430, Processing Time 0.023 seconds

A Study on the Indoor Air Pollution Levels in the Classrooms at Public Schools in Suwon (수원지역 초.중.고등학교 교실의 실내 공기오염도에 관한 연구)

  • 신은상;김진우
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.20-27
    • /
    • 2002
  • This study has researched the indoor air Pollution in the school classrooms. It focused on the school classrooms in which the students take part in many loaming activities for a long time, not focused on the offices or underground facilities that have occupied the interest so far. First, I investigated the origination sources of indoor air pollution which influences on our health, and researched the data on the consequences of it on the human body. Second, I measured the indoor air Pollution level of the classrooms in which the students take part in activities. I selected CO, $CO_2,{\;}SO_2,{\;}NO_2$and $PM_{10}$ as the research items. Each two schools were chosen in the elementary schools, middle schools and high schools as the ones for measurement. And I distinguished the boys' schools from the girls' schools in the middle and high schools. CO, $SO_2{\;}and{\;}NO_2$were comparatively low comparing with the recommendation of the Ministry of Environment. But, $CO_2{\;}and{\;}PM_{10}$ exceeded the standard concentration in most schools and there was a difference between boys'classrooms and girls'classrooms about them. Also, it was different by the number of members a classrooms. Third, I made a questionnaire on the on the indoor air pollution. The questionnaire showed that many students feel the indoor air pollution directly and they are under the influence of it.

An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units (기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan (울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

Chemical pollution of indoor air in Japan

  • Takehiko, Ogawa
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2000.11b
    • /
    • pp.1-21
    • /
    • 2000
  • Recently, indoor air pollution from chemical compounds has been attracting attention. Sick-house syndrome and hypersensitivity to chemical compounds are also being recognized as health problems. In this presentation, the situation of indoor air pollution by chemical compounds in Japan will be explained.

  • PDF

Occupational asthma related to indoor air pollution in a worker at an indoor air gun shooting range: a case report

  • Kwang Min Lee;Seungho Lee;Yoon-Ji Kim;Seung-eun Lee;Youngki Kim;Dongmug Kang;Se-Yeong Kim
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.13.1-13.12
    • /
    • 2023
  • Background: Indoor air pollution can cause and exacerbate asthma. We report a previously undescribed case of occupational asthma related to indoor air pollution in a worker at an indoor air gun shooting range and highlight the potential risk of developing occupational asthma in this environment. Case presentation: A 31-year-old man presented with dyspnea, cough, and sputum and was diagnosed with asthma complicated by pneumonia. Objective evidence of asthma was obtained by performing a methacholine bronchial provocation test. It was suspected that the patient had occupational asthma, which began one month after changing jobs to work within the indoor air gun shooting range. The highest peak expiratory flow (PEF) diurnal variability on working days was 15%, but the highest variation was 24%, with 4 days out of 4 weeks having a variation of over 20% related to workplace exposure. Conversely, the diurnal variability on the rest days was 7%, and no day showed a variation exceeding 20%. The difference in the average PEF between working and rest days was 52 L/min. PEF deterioration during working days and improvement on rest days were noted. Conclusions: The results obtained from the in-depth analysis of the PEF were adequate to diagnose the patient with occupational asthma. Exposure to indoor air pollution and lead and the patient's atopy and allergic rhinitis may have contributed to the development of occupational asthma.

Measurement of Indoor Air Quality in a Kindergarten (유치원내 실내공기환경 측정)

  • Kim, Yun-Deok;Lim, Soo-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.1
    • /
    • pp.52-57
    • /
    • 2007
  • Kindergarten children are engaged in the age of physical immaturity as well as the rapid growth. The indoor air contaminants that are proved to affect even the full grown adults are obvious to have no little influence to immature small children in a growth period. In May 2004, for the multi purpose facilities and newly constructed apartments, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. However, since the kindergarten takes none of the classifications, even the current condition is not grasped although it is directly connected to the health of growing children. Therefore, the study aims to analyze indoor air pollution of one selected kindergarten in Incheon city.

Review of Internet of Things-Based Artificial Intelligence Analysis Method through Real-Time Indoor Air Quality and Health Effect Monitoring: Focusing on Indoor Air Pollution That Are Harmful to the Respiratory Organ

  • Eunmi Mun;Jaehyuk Cho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.1
    • /
    • pp.23-32
    • /
    • 2023
  • Everyone is aware that air and environmental pollutants are harmful to health. Among them, indoor air quality directly affects physical health, such as respiratory rather than outdoor air. However, studies that have examined the correlation between environmental and health information have been conducted with public data targeting large cohorts, and studies with real-time data analysis are insufficient. Therefore, this research explores the research with an indoor air quality monitoring (AQM) system based on developing environmental detection sensors and the internet of things to collect, monitor, and analyze environmental and health data from various data sources in real-time. It explores the usage of wearable devices for health monitoring systems. In addition, the availability of big data and artificial intelligence analysis and prediction has increased, investigating algorithmic studies for accurate prediction of hazardous environments and health impacts. Regarding health effects, techniques to prevent respiratory and related diseases were reviewed.

The Study on the Indoor Air Quality in a Newly Built Apartment Rouse by Field Measuring (실측을 통한 신축공동주택의 실내공기질에 관한 연구)

  • Lee Kyung-Hee;Bae Jong-Soo;Cho Sung-Woo;Park Min-Yong;Park Chang-Sub;Choi Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.111-117
    • /
    • 2006
  • The harmfulness of HCHO and VOCs from construction material and furniture has been increased gradually. It must be need to prevent pollution materials' accumulation indoor effectively and to remove very small amount of harmful pollution materials in various plans, because these kinds of pollution materials greatly affect human body, Therefore, this study is focused to find out the improvements of Indoor Air Quality in execution of natural ventilation and bakeout to reduce indoor chemical pollution materials or not. After effects of indoor air quality by natural ventilation and bake-out being examined, it is follows the conclusion. As for the density change of TVOC and Toluene according to time lapse, in case the middle and high-story areas have bake-out, the density increased once, but it showed the gradual decrease after bake-out was stopped, and it was shown that it exceeded the standards recommended for newly built apartment. The bake-out is effective to discharge the HCHO and TVOC from the construction material and the furniture, and the natural ventilation is effective remove the indoor pollution materials.

Towards Quantitative Assessment of Human Exposures to Indoor Radon Pollution from Groundwater

  • Donghan Yu;Lee, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.43-51
    • /
    • 2001
  • A report by the national research council in the United States suggested that many lung cancer deaths each year be associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundations. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the quantitative assessment of human exposures to radon released from the groundwater into indoor air. At first, a three-compartment model is developed to describe the transfer and distribution of radon released from groundwater in a house through showering, washing clothes, and flushing toilets. Then, to estimate a daily human exposure through inhalation of such radon for an adult. a physiologically-based pharmacokinetic(PBPK) model is developed. The use of a PBPK model for the inhaled radon could provide useful information regarding the distribution of radon among the organs of the human body. Indoor exposure patterns as input to the PBPK model are a more realistic situation associated with indoor radon pollution generated from a three-compartment model describing volatilization of radon from domestic water into household air. Combining the two models for inhaled radon in indoor air can be used to estimate a quantitative human exposure through the inhalation of indoor radon for adults based on two sets of exposure scenarios. The results obtained from the present study would help increase the quantitative understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF