• Title/Summary/Keyword: Indoor Air Control

Search Result 455, Processing Time 0.024 seconds

Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores (현장측정을 통한 대형 할인매장의 실내환경 평가)

  • Park Byung-Yoon;Jung Yong-Ho;Ham Heung Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of $CO_2$, CO gas and TSP were measured and evaluated. In each case of $CO_2$, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from $18^{\circ}C$ to $28^{\circ}C$ according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

On-line Optimal Control Technology for Central Heating System (중앙난방시스템의 온라인 최적제어기법에 관한 연구)

  • Ahn Byung Cheon;Choi Sang Gon;Cho Sung Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.140-146
    • /
    • 2005
  • The on-line optimal control algorithm for central heating system has been researched for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as indoor heating load and outdoor temperature variation. This study has been done by using TRNSYS Program in order to analyze the central heating system. The optimal control algorithm shows good energy Performances in comparison with the conventional one.

Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses (신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

Influence Factors and Management based on Phase of Building Construction for the Improvement of Post Occupancy Indoor Air Quality

  • Lim, Hyoung-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.576-586
    • /
    • 2011
  • In recent years, pollution in residential spaces has been a significant area of concern. In particular, the indoor air quality (IAQ) of an apartment building before occupancy, which is related to the interior material, is a serious problem. Unlike previous research, which has mainly focused on pollution control after construction, this study has derived influencing factors and priority of management with a controlling schedule for IAQ. The objectives of this research are 1) control of schedule or improvement of management for IAQ, 2) distribution of responsibility to the parties concerned (factory, material company, construction company, design and engineering, occupancy). The results show the relative priority of the four major items in wall?based apartment buildings and in column?based apartment buildings. An analysis of the parties responsible for improvement based on the IAQ results shows more efforts to improve IAQ are needed in material factories and engineering/design companies.

New approaches of Indoor Environmental Control for Energy Saving-Adaptive Model (에너지절감을 도모하는 실내 온열환경 제어논리-Adaptive Model)

  • Song, Doo-Sam;Kato, Shinsuke
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.838-846
    • /
    • 2006
  • The purpose of this study to develop the air-conditioning system that adopts adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the past heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be describe the thermal comfort of inhabitant who stay at hybrid system controlled buildings with accuracy. In this paper, the concept of adaptive model will be described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker will be reported.

  • PDF

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics (민감시설의 건물 특성에 따른 실내공기질 분석)

  • Cho, Kyunghwa;Kwon, Soonjung;Sung, Minki;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in 'IAQ Control In Public-Use Facilities, etc. Act'. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique (정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석)

  • Yoon, Young H.;Joo, Jin-Chul;Ahn, Ho-Sang;Nam, Sook-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6610-6617
    • /
    • 2013
  • This study examined the current and future Indoor Air Quality (IAQ) control device markets and analyzed the recent studies on indoor air pollutantr emoval to develop a new technology for fine dust control. Currently, the mechanical filter technique occupies the bulk of the IAQ control market but the electronic technique is emerging as an alternative to control fine dust efficiently. Among the gaseous VOCs and fine dust particles contaminating the indoor air quality, fine dust particles are more problematic because they threaten human health by penetrating deep into the body and producing secondary contaminants by chemical reaction with VOCs. The electronic IAQ control device using dielectrophoretic and electrostatic forces is a good option for public spaces where many people pass, and at the same time, it needs to consider temperature, humidity, and the particle properties of specific areas to highlight the control efficiency. Electronic-related technology is expected to be used widely in many public/private spaces wherever a dust-free environment is required.

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

Effect of Occupants' Behaviour of Environmental Control on Improvement of Air Environment in Winter's High School Classroom (겨울철 고등학교 교실에서 재실자의 환경조절행동이 공기환경 개선에 미치는 영향)

  • Kwak, Ro-Yeul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.163-172
    • /
    • 2020
  • In this study, the effect of window opening, which is a control mechanism for air control in winter high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. And the changes in air environment were assessed by the performance of the duster cleaning work in the classroom. It was found that 84.6% of the students surveyed said the air was stuffy. And among the alternatives, opening windows all times during class was most effective in reducing CO2 concentration and PM concentration was measured within classroom's standard. In addition, the concentration change rate of duster cleaning work was reduced by 74.4% and 65.4% of PM10 compared to broom cleaning work.