• 제목/요약/키워드: Indoor $CO_2$concentration

검색결과 182건 처리시간 0.022초

빌딩 地下商街의 空氣性狀 및 분자의 變異原性 (Air Contamination in an Underground Commercial Floor assayed by GAseous Pollutants, Dusts and Mutagenicity)

  • 兪榮植
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.46-52
    • /
    • 1987
  • There are many factors such as airtighteness and high density of merchandises or passengers that contaminate indoor air in underground commercial floor. So it is very important to know air quality and quantity of contamination in underground market increasing in number lately. It was from these viewpoints that gaseous pollutants, dusts and mutagenicity of organic compounds extracted from dusts in an underground market were investigatd. Organic ompounds (tar) were extracted by Soxhlet extractor with benzene as a solvent. Mutagenicities of these extracts were evaluated by the preincubation method using Salmonella typhimurium TA 100 and TA 98 strains with and without S9mix. The results obtained were as follows: It seemed to be under the influence of outdoor air that the concentrations of $CO, CO_2, NO, NO_2$ and dusts were higher in winter than summer. The concentration of $CO_2$ was higher in indoor than outdoor, but the concentration of NOx was similar in both sampling areas. Metal contents in dusts attached to the ventilation ducts were as follows showing in order of high concentration : Fe (9000-22000ppm), Zn(1200-2300ppm) and Pb (280-590ppm). The contents of tar were 6-33% of dusts, and higher than those from dusts collected by high volume air sampler. The extracts from dusts attached to the inlet duct exhibited lower mutagenicity than those from dusts attached to the outlet duct. This finding seemed to suggest that mutagenic substances were in creasing in underground. There was no seasonal difference of mutagenicity toward TA 98. Toward TA 100 in the presence of S9mix, the mutagenicity was about 3 fold higher in winter than summer. The mutagenicities of tar extracted from dusts collected by high volume air sampler were different from those attached to the ventilation ducts. The former showed 2-3 fold higher mutagenicity than the latter toward TA 100. However no difference showed between the former and the latter toward TA 98 in the absence of S9mix, but the former was 4-5 fold higher than the latter in the presence of S9mix.

  • PDF

청주시 아파트 일반가정의 겨울철 실내열·공기환경 현장측정조사 (The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City)

  • 조준행;최윤정
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.111-120
    • /
    • 2013
  • The purposes of this study were to investigate the actual state of the indoor thermal and air environment in general apartment houses during winter in Cheongju City, to analyze the related factors with the indoor thermal and air environment, and to make suggestions for the improvement. A series of visiting field investigation was conducted in twenty units between 28th December, 2010, and 11th March, 2011. The field investigations included the measurement of physical indoor environmental conditions, the observation of architectural characteristics and resident's behavior, and the on-site questionnaire survey of residents. The measured values of each units were compared to evaluation standard and were categorized to group by the difference between units. Factors related to the difference of the measured values between the groups were analyzed. The findings are summarized as followed. The indoor temperature of apartment houses during winter in Cheongju City was generally suitable. The relative humidity was slightly dry, while the $CO_2$ concentration was found to be excessively high. The factors related indoor environment were analysed as heating operation, ventilation, gas range use, and hanging out the wash to dry in indoors.

Purification of BTEX at Indoor Air Levels Using Carbon and Nitrogen Co-Doped Titania under Different Conditions

  • Jo, Wan-Kuen;Kang, Hyun-Jung
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1321-1331
    • /
    • 2012
  • To date, carbon and nitrogen co-doped photocatalysts (CN-$TiO_2$) for environmental application focused mainly on the aqueous phase to investigate the decomposition of water pollutants. Accordingly, the present study explored the photocatalytic performance of CN-$TiO_2$ photocatalysts for the purification of indoor-level gas-phase aromatic species under different operational conditions. The characteristics of prepared photocatalysts were investigated using X-ray diffraction, scanning emission microscope, diffuse reflectance UV-VIS-NIR analysis, and Fourier transform infrared (FTIR) analysis. In most cases, the decomposition efficiency for the target compounds exhibited a decreasing trend as input concentration (IC) increased. Specifically, the average decomposition efficiencies for benzene, toluene, ethyl benzene, and xylene (BTEX) over a 3-h process decreased from 29% to close to zero, 80 to 5%, 95 to 19%, and 99 to 32%, respectively, as the IC increased from 0.1 to 2.0 ppm. The decomposition efficiencies obtained from the CN-$TiO_2$ photocatalytic system were higher than those of the $TiO_2$ system. As relative humidity (RH) increased from 20 to 95%, the decomposition efficiencies for BTEX decreased from 39 to 5%, 97 to 59%, 100 to 87%, and 100 to 92%, respectively. In addition, as the stream flow rates (SFRs) decreased from 3.0 to 1.0 L $min^{-1}$, the average efficiencies for BTEX increased from 0 to 58%, 63 to 100%, 69 to 100%, and 68 to 100%, respectively. Taken together, these findings suggest that three (IC, RH, and SFR) should be considered for better BTEX decomposition efficiencies when applying CN-$TiO_2$ photocatalytic technology to purification of indoor air BTEX.

Pattern Recognition을 이용한 지하상가에서의 대기오염물질의 농도 분석에 관한 연구 (The Air Quality Analysis in Underground Shopping Centers Using Pattern Recognition)

  • 김동술;김형석
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 1990
  • The purpose of the study was to analyze air quality in underground shopping centers using pattern recognition methods. In order to perform this, the concentraion of air pollutants such as $CO, NO_2, NO_x, SO_2$, and particulate matters was measured at the 11 different shopping centers in Seoul metropolitan area and the total of 47 samples were obtained at random based on the size of shopping centers. To introduce a new concept of the "average concentration" for the indoor air quality analyses, the various multivariate statistical analyses have been studied. Thus, a cluster analysis was applied to separate the samples into pseudo-patterns and a disjoint principal component analysis was used to generate homogeneous patterns after removing outliers from the pseudo-patterns. The 6 homogeneous patterns were then obtained as follows:the first pattern was a group of clean sites;the second a group of sites having high dust concentration;the third a group of sites having high dust and $NO_x$ concentration;the fourth a group of sites having low dust and $SO_2$ concentraion and high CO concentration;the fifth a group of sites having high $NO_2 and SO_2$ concentration;and the final a group of miscellaneous sites. Thus, the average concentration could be estimated for each pattern.h pattern.

  • PDF

중등학교 교실의 이산화탄소(CO2) 관리를 위한 지능형 창호개폐 작동 프로세스 (Intelligent and Responsive Window Opening-Closing Operation Process for Carbon Dioxide(CO2) Management of Secondary School Classroom)

  • 최윤영;이현수
    • 교육시설 논문지
    • /
    • 제25권4호
    • /
    • pp.19-30
    • /
    • 2018
  • The school classroom is a common living place where students spend 7 to 14 hours a day to prepare for their careers. Therefore, if the ventilation of the classroom is not properly performed, it may lead to the deterioration of learning ability due to the unclear air. The concentration of carbon dioxide in the classroom is reported to be high, and the increase in carbon dioxide concentration has a negative effect on the learner's academic performance. In this context, the purpose of this study is to propose a methodology for intelligent and responsive window opening-closing operation process that can reduce the concentration of $CO_2$ in the classroom in order to build a support space that can create an effective teaching-learning environment for adolescents. The specific objectives are as follows. First of all, we define the concept of window opening-closing operation. Secondly, twe develop the operation process of window opening-closing. Thirdly, we develop an algorithm for real-time window opening and closing (process) (Window Opening-Closing Operation Process). Finally, we verify the intelligent responsive window opening-closing operation process through developing examples of window opening-closing operation process using the parametric design program. This study is a preliminary study to develop algorithms necessary for window opening-closing operation. Based on the first-order algorithm, We simulated window opening-closing operations according to a hypothetical scenario. As a result, This study can show that the window is open and close depending on the $CO_2$ concentration, but the $CO_2$ concentration in the room is higher than outdoors. Consequentially, we suggest that it is necessary to develop an algorithm to supplement these results because window is often not working when the temperature difference between indoor and outdoor in winter is large.

가스렌지와 창문위치에 따른 주방 배기성능 예측 (Prediction of the ventilation performance in a kitchen with various locations of gas range and window)

  • 김경환;이재헌;박명식;이대우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

대학건물 실내 에어로졸입자의 입경별 질량농도 특성 (Characteristics of Size-segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings)

  • 서정민;왕빈;장성호;박정호;최금찬
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.453-461
    • /
    • 2014
  • Objective: Based on the fact that fine particles are more likely to produce negative influences on the health of occupants as well as the quality of indoor air compared to coarse particles, it is critical to determine concentrations of aerosol particles with different sizes. Thus, this study focused on the size distribution and concentrations of aerosol particles in university buildings. Method: Aerosol particles in indoor air were collected from four areas: corridors in buildings(In-CO), lecture rooms(In-RO), laboratories(In-LR), and a cafeteria(In-RE). Samples were also collected from outside for comparison between the concentrations of indoor and outdoor particles. For the collection of the samples, an eight stage non-viable cascade impactor was used. Result: The average concentration of $PM_{10}$ in the samples collected from indoor areas was $34.65-91.08{\mu}g/m^3$,and the average for $PM_{2.5}$ was $22.65-60.40{\mu}g/m^3$. The concentrations of the aerosol particles in the corridors, lecture rooms, and laboratories were relatively higher than the concentrations collected from other areas. Furthermore, in terms of mass median aerodynamic diameter(MMAD), the corridors and lecture rooms had higher numbers due to their characteristics, showing $2.36{\mu}m$ and $2.11{\mu}m$, respectively. Laboratories running an electrolysis experiment showed $1.58{\mu}m$, and the cafeteria with regular maintenance and ventilation had $1.96{\mu}m$. Conclusion: The results showed that the $PM_{10}$ concentrations of all samples did not exceed indoor air quality standards. However, the $PM_{2.5}$ concentration was over the standard and, in particular, the concentration of fine particles collected from the laboratories was relatively higher, which could be an issue for the occupants. Therefore, it is important to improve the quality of the indoor air in university buildings.

제올라이트 5A와 13X의 저농도 이산화탄소 흡착 및 탈착특성 (Adsorption and Desorption Characteristics of Carbon Dioxide at Low Concentration on Zeolite 5A and 13X)

  • 조영민;이지윤;권순박;박덕신;최진식;이주열
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.191-200
    • /
    • 2011
  • A way to adsorptively remove indoor carbon dioxide at relatively lower concentration under ambient temperature was studied. A small lab-scale carbon dioxide adsorption and desorption reactors were prepared, and 5A and 13X zeolites were packed in this reactors to investigate their adsorption and desorption characteristics. The inflow carbon dioxide concentration was controlled to 5,000 ppm, relatively higher concentration found in indoor spaces with air quality problems, by diluting carbon dioxide with nitrogen gas. The flow rate was varied as 1~5 L/min, and the carbon dioxide concentration after this reactor was constantly monitored to examine the adsorption characteristics. It was found that 5A adsorbed more carbon dioxide than 13X. A lab-scale carbon dioxide desorption reactor was also prepared to investigate the desorption characteristics of zeolites, which is essential for the regeneration of used zeolites. The desorption temperature was varied as $25{\sim}200^{\circ}C$, and the desorption pressure was varied as 0.1~1.0 bar. Carbon dioxide desorbed better at higher temperature, and lower pressure. 5A could be regenerated more than three times by thermal desorption at $180^{\circ}C$. It is required to modify zeolites for higher adsorption and better regeneration performances.

사무실의 실내 청소 과정에서 부유하는 미세먼지의 크기분포 (Size distributions of suspended fine particles during cleaning in an office)

  • 지준호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.25-33
    • /
    • 2018
  • 본 연구에서는 청소 과정에서 바닥에 먼지가 실내 공기 중으로 비산되는 특성을 공기 중 미세먼지를 측정하여 분석하였다. 신발을 벗지 않고 생활하는 국내 사무실을 대상으로 하였고, 실내 청소 과정에서 발생하는 미세먼지를 측정하였다. 미세먼지($PM_{10}$)와 초미세먼지($PM_{2.5}$)와 $1{\mu}m$ 보다 작은 먼지의 무게농도($PM_{1.0}$)을 분석하였고, 청소 과정에서 발생하는 $0.3{\mu}m$ 이상의 먼지의 크기를 측정하여 분석하였다. 특히, 빗자루질과 진공청소기를 사용하는 과정에서 재비산 되는 미세먼지의 특성을 분석하였고, 입자의 크기에 따른 재비산 특성과 실내 농도 변화 특성을 확인하였다. $PM_{2.5}$$PM_{10}$은 청소 시작과 함께 농도가 증가하였고, 청소 이후에도 실내에 부유하여 장시간 인체에 노출될 수 있을 것으로 보인다. 반면에 $PM_{1.0}$은 상대적으로 청소과정에서 농도가 증가하는 경향을 확인할 수 없었다. 특히, $2.5{\sim}10{\mu}m$ 크기의 먼지는 바닥에 먼지가 많은 조건에서 빗자루질로 청소하는 경우, 초기 농도의 약 60배까지 높아질 수 있음을 확인하였다. 바닥에 먼지가 적은 조건에서 진공청소기를 사용하는 경우도 $2.5{\sim}10{\mu}m$ 크기의 먼지가 증가하였지만 초기 농도의 5배 이하였다. 중성능급 배기필터가 장착된 진공청소기가 가동하는 동안 CPC로 측정된 총 개수농도가 급격히 증가한 후 감소하는 특성이 나타났다. 개수로 대부분을 차지하는 먼지는 250 nm 보다 작은 크기였다. 실내 거주자의 미세먼지 노출은 외부에서 유입된 대기 미세먼지와 실내에서 발생된 실내 생성 미세먼지가 함께 영향을 준다고 알려져 있다. 그렇지만, 국내 실내 활동 중 발생되는 미세먼지에 대한 체계적인 측정과 분석 연구가 많지 않았다. 이미 진행되고 있는 다양한 대기 미세먼지 연구 뿐 아니라 앞으로는 실내의 다양한 활동에 기인한 미세먼지 생성 특성에 대한 심도 깊은 연구가 필요할 것으로 생각된다.

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.