• 제목/요약/키워드: Indoor(basement)

검색결과 27건 처리시간 0.026초

기술사마당: 기술자료 -초고층(超高層) 건물(建物) 내(內)에서 누설동축케이블을 이용한 무선통신(無線通信)네트워크 구축(構築) 방안- (Using leak coaxial cable, a wireless communications network plan in high-rise buildings)

  • 이순종;이문호
    • 기술사
    • /
    • 제44권5호
    • /
    • pp.42-47
    • /
    • 2011
  • Currently, wireless communication environment in high-rise buildings are limited in the basement and ground floor facilities are not in common use do not part, in case of disaster is difficult for efficient repression. In this paper, wireless communication facilities on the ground floor of the skyscraper by building infrastructure, wireless communications is proposed to eliminate shadows. That the presence of various wireless communication systems, wireless communication system proposed by this paper, TPS laying coaxial cable seals leak, and the propagation shades in place by installing indoor antenna is the solution to eliminate shadows. The wireless communications solutions reveal the advantages and features, a method of constructing the proposed design.

  • PDF

지구화학환경에서의 라돈농도분포와 라돈농도의 지배요인(사례연구) (Radon distribution in geochemical environment and controlling factors in Radon concentration(Case study))

  • 전효택
    • 지질공학
    • /
    • 제10권2호
    • /
    • pp.189-214
    • /
    • 2000
  • 기반암별로 구획화된 지역(서울대학교 관악캠퍼스, 경기도 가평, 충북 보은)에서의 사례연구결과, 화강암질 암석의 잔류토양에서 라돈농도가 상대적으로 높은 값을 나타냈다. 이는 기반암에 따른 우라늄의 지구화학적 분포의 차이가 1차적 원인으로 작용했기 때문이라 판단된다. 라돈의 발산율에 영향을 미치는 토양의 함수율과 우라늄-라듐간의 방사는평형도 토양가스 중 라돈농도를 지배하는 2차적 요인임이 실험에 의해 증명되었다. 서울대학교 관악캠퍼스 지역에서 선정한 40개의 실내공간에서 라돈 및 리돈후대핵종농도 분포를 조사한 결과, 지하실에 위치하면서 환기가 불량한 일부 실내공간에서 EPA의 라돈 기준치인 4pCi/L을 초과하는 농도를 나타냈다. 또한, 실내에서의 라돈농도와 비교한 결과, 일반적으로 양의 상관성을 보여, 토양가스가 실내라돈유입의 주 원임이 확인되었다. 단층이 위치한 경주 및 가평지역에서 단층선과의 거리에 따른 라돈농도분포를 조사한 결과, 일부 지역에서 단층구조의 영향으로 인해 라돈의 이동성이 증가하여, 해당 토양의 우라늄함량만으로는 설명할 수 없는 라돈이상치가 나타났다.

  • PDF

구한말 서울 정동의 러시아공사관에 대한 복원적 연구 (A Study on the Restoration of the Russian Legation in Jeongdong Seoul in the Latter Era of Choseon Dynasty)

  • 김정신;발레리 알렉산드로비치 사보스텐코;김재명
    • 건축역사연구
    • /
    • 제19권6호
    • /
    • pp.61-78
    • /
    • 2010
  • Old Russian Legation(1890) has been attracted public attention in terms of politics and foreign affairs than architectural style because of conditions of location and historical incident. Though it was heavily damaged during the Korean war, and only the tower has been restored, it is very important in architectural history in Korea, because it is the oldest western style brick building which is existing with the old bishop's house in Myeong-Dong. But it has been impossible to reveal exactly the original form as there has been few reliable materials(picture, drawing, document) and it's remains were nearly destroyed owing to development of the surroundings. Recently the decisive document(site outline map) was found, and new research on the architect Sabatine was studied. So I can get into close with the original form by the results. In this study, I tried to conjecture the original form of the old Russian legation(the size, style, plan and indoor space, arrangement of attached facilities) and I checked the location and structure of the room where King Gojong stayed when he took refuge, and the use of the passage in the basement.

의료기관 지하시설의 라돈가스 측정과 내부피폭 조사 (Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure)

  • 송재호;진계환
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.231-235
    • /
    • 2011
  • 라돈($^{222}Rn$)은 지각의 암석이나 토양 또는 건축자재 중에 들어 있는 우라늄($^{238}U$)과 토륨($^{232}Th$)이 몇 단계의 방사성붕괴과정을 거친 후 생성되는 무색무취의 불활성기체로 광산이나 지하같이 밀폐된 공간에 잘 축적된다. 호흡기를 통하여 폐로 유입되고 라돈의 딸핵종이 폐나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 사람의 생명을 다루는 의료기관에서의 라돈피폭은 평상시 방사선피폭량이 많은 방사선관계종사자와 면역력이 약한 환자에게 큰 위험이 될 수 있다는 판단에 이 실험을 실시하였다. 실험에 쓰인 계측기는 실시간 라돈측정기인 Professional Continuous Radon monitor이며 계측장소는 두 개의 병원 지하1층에서 지상2층까지 층별로 오전 10시부터 오후 3시까지 측정 하였다. Professional Continuous Radon monitor계측결과는 최소 14.8 Bq/$m^3$에서 최대 70.3 Bq/$m^3$로 국내기준치인 148 Bq/$m^3$이하로 나타났으며 유효선량은 최소 0.296 mSv에서 최대 1.406 mSv로 일년간 자연방사선으로부터 피폭되는 방사선량인 2.4 mSv의 10~58.3% 수준으로 나타났다.

공동주택을 대상으로 한 탄소배출 평가기준 구축 및 평가방법 개발 (A Study on The Evaluation Criteria of Carbon Emission and the Development of the Evaluation Method in Apartment House)

  • 최두성;전흥찬
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.79-88
    • /
    • 2013
  • This study creates the evaluation criteria to analyze the $CO_2$ emission quantity in the complex of apartment house among domestic buildings and proposes how to calculate the $CO_2$ emission quantity by the only simple information of apartment house. The study shows that in order to create the index of carbon emission evaluation criteria, $CO_2$ emission quantity for its input materials in these 27 apartment houses are 445,412g-$CO_2/m^2$ for apartment building, 474,322g-$CO_2/m^2$ for the basement parking lot, 483,523g-$CO_2/m^2$ for welfare facility, 729,957g-$CO_2/m^2$ for sales facility, 743,560g-$CO_2/m^2$ for other facility, 26,782g-$CO_2/m^2$ for public facility, 43,659g-$CO_2/m^2$ for landscape, 1,113g-$CO_2/m^2$ for indoor facility, 11,251g-$CO_2/m^2$ for outdoor facility and 891g-$CO_2/m^2$ for common temporary based on the average $CO_2$ emission by facility. We can also see the analysis data that in case of using the selected factors only, the rate of error is 7.51% comparing with the emission quantity by using simplified LCA method this study suggests for the whole range of apartment houses and the rate of error is average 3.24% using selective and main materials. And this it is evaluated that we can get the result which is similar to the actual $CO_2$ emission quantity with only the simple information about the apartment house.

국가기본도용 Hybrid 공간정보 모델 개발 (Development of Hybrid Spatial Information Model for National Base Map)

  • 황진상;윤홍식;유재용;조성환;강성찬
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.335-341
    • /
    • 2014
  • 새로운 정보기술 환경에 적합한 국가기본도용 데이터 및 DB 모델을 개발하고자 본 연구에서는 시공간지도구조, 정보연계용 프레임워크지도, 다중레이어 토폴로지구조 등을 주요 특징으로 하는 Hybrid 공간정보 모델을 개발하였다. 공간정보에 "시간"이라는 새로운 차원을 추가하여 공간객체의 시간에 따른 변화가 반영되는 DB 구조를 설계하였고, 다축척 융합지도 구조와 고유 ID 체계를 부여하여 타 정보와 연계 융합하여 활용할 수 있도록 하였다. 또한 기존 2차원 지도의 표현상 한계를 극복하고자 실내 및 지하정보를 포함하는 구조와 지형 지물에 대한 토폴로지 및 복합표현 구조를 설계하였다. 설계결과를 반영한 시범구축을 통해 개발된 모델의 성능을 평가한 결과 다양한 정보들과의 시공간 연계를 통해 활용도가 향상된 국가기본도용 데이터 및 DB 모델의 구현 가능성을 확인할 수 있었다.

서울 지하철역(地下鐵驛) 승강장(昇降場) 및 토양내(土壤內) 유해(有害)라돈함량(含量) 연구(硏究) (Radon-222 Concentrations of Metropolitan Subway Stations and Soils in the Seoul)

  • 홍영국;김승오;김통권
    • 자원환경지질
    • /
    • 제31권3호
    • /
    • pp.215-222
    • /
    • 1998
  • The radon (Rn-222) potential of metropolitan subway stations and soils in Seoul city were delineated using alpha-track filter and EDA-200 radon detectors, respectively. The uranium (U) and thorium (Th) contents were also determined using a Multi Channel Analyzer to identify the sources of radon gas. The average U concentrations in Seoul varies according to basement rock types. For example, there is $9.40{\pm}10.11ppm$ in the Precambrian metasedimentary rock (PM), $9.08{\pm}2.85ppm$ in the Jurassic Kwanaksan granite (JK) and $4.94{\pm}1.43ppm$ in the Jurassic Seoul granite (JS). Uranium contents in soil samples are $10.30{\pm}4.74ppm$ in JK, $10.10{\pm}7.43ppm$ in PM and $6.69{\pm}3.95ppm$ in JS and these closely reflect the content of uraniferous minerals. The levels of soil radon are $604{\pm}273pCi/L$ in JK, $502{\pm}275$ in JS and $262{\pm}211pCi/L$ in PM. The soil radon concentrations are shown to reflect soil permeability and porosity rather than their U contents. The mean indoor radon contents in subway stations are $1.50{\pm}0.62pCi/L$ on the 4th line, $1.41{\pm}0.95pCi/L$ on the 3rd line, $0.84{\pm}0.13pCi/L$ on the 1st line and $0.80{\pm}0.25pCi/L$ on the 2nd line. The subway stations located in the JK have the highest average radon concentration with $2.04{\pm}0.65pCi/L$, where levels of $1.57{\pm}0.81pCi/L$ occur in the JS and $0.80{\pm}0.23pCi/L$ in the PM. The highest radon levels of 4.1 pCi/L occur mainly in Keongbokkung station on the 3rd line and these exceed 4 pCi/L of the US EPA action level.

  • PDF