• 제목/요약/키워드: Indoor(basement)

검색결과 27건 처리시간 0.023초

Characterization of Indoor Temperature and Humidity in Low-income Residences over a Year in Seoul, Korea

  • Lee, Daeyeop;Lee, Kiyoung;Bae, Hyunjoo
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권3호
    • /
    • pp.184-193
    • /
    • 2017
  • People spend the majority of their time in indoor environments. Maintaining adequate indoor temperature and humidity is necessary to support health and improve quality of life. However, people with low incomes can be vulnerable because they may not be able to use effective cooling and heating systems in their homes. In this study, the indoor temperature and humidity in low-income residences over a year in Seoul, Korea was characterized. Indoor temperature and humidity were measured in three types of homes (12 rooftop residences, 16 basement residences, and 18 public rental apartments) occupied by low-income residents. Both differed significantly among the three types of residence, particularly during the summer and winter seasons. A regression model between indoor and outdoor temperature detected a heating threshold at $3.9^{\circ}C$ for rooftop residences, $9.9^{\circ}C$ for basement residences, and $17.1^{\circ}C$ for public rental apartments. During tropical nights and cold-wave advisory days, rooftop residences showed the most extreme indoor temperatures. This study demonstrates that people living in rooftop residences could be at risk from extreme hot and cold conditions.

실내의 석면농도 실태 조사 및 저감에 관한 연구 (A study on the survey and reduction of indoor asbestos concentration)

  • 서병원;이주화;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.325-337
    • /
    • 2014
  • The research on the actual condition of indoor asbestos concentration in Korea has not been thoroughly accomplished up to now. In this research the ratio of asbestos-containing buildings and indoor asbestos concentration was studied. This investigation was conducted in 2012 and 2013 and buildings were categorized based on region, building type by use, existing space(ground or basement), and construction year, respectively. Also the indoor asbestos concentration change was monitored to evaluation the efficiencies of two types of asbestos-concentration abatement devices. As a result, the ratio of asbestos-containing buildings in Seoul was largely decreased. The ratio of asbestos-containing buildings was higher in hospitals and schools regionally and in ground buildings than in basement. The average indoor asbestos concentrations were 0.0011, 0.0008 piece/cc in 2012 and 2013 investigation, respectively. Those values were much lower than standards(0.01 piece/cc), therefore the threat of indoor asbestos concentration might be negligible. In asbestos-concentration abatement experiments, the circulation velocity of ventilator were changed 2-6.7 m/sec. With 6.7 m/sec of velocity of ventilator, the concentration of indoor asbestos was fluctuated and maximum value was 2.4 piece/cc. With 4.5 and 2 m/sec of velocities of ventilator, the maximum concentration of indoor asbestos was fluctuated and maximum value was 0.9 piece/cc. This indicated that the concentration of indoor asbestos was decreased partly due to the free drop of asbestos. From these results, the proper velocity of ventilator seems to be between 4.7 and 6.5m/sec under this circumstance and further research is required. These research results may be used to guideline of asbestos management policy.

Alpha Track Detector를 이용한 실내외 라돈 농도조사에 관한 연구 (A Survey of Indoor and Outdoor Radon Concentrations by Alpha Track Detector in Korea)

  • 김윤신;이철민;김현탁
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.71-76
    • /
    • 2002
  • A survey of radon concentrations in both indoor and outdoor atmospheres was carried out using EIRM and Cup Monitor for the period of February 1996 to March 1997. EIRM were used to measure the indoor and outdoor radon concentration at five major cities university. Cup Monitor were also used to measure the indoor radon concentrations at shopping store, office building, apartment, hospital and house in Seoul. The mean indoor and outdoor radon concentrations at the five major cities(Seoul, Daegu, Daejon, Cwangiu and Busan) were 24.1 Bq/m$^3$and 8.62 Bq/m$^3$, respectively. The ratio of indoor to outdoor radon concentrations ranged front 1.7 to 3.9. Inspection of its seasonal distribute pattern indicates the enhancement during winter relative to summer, consistently for both indoor and outdoor air. The results of the survey showed that the concentrations in basements were clearly higher than those in usual living/working places.

지중공간(地中空間)의 자연실온(自然室溫) 추정(推定)에 관(關)한 연구(硏究) (A Study on the Estimations of the Indoor Natural Temperature in the Underground Space)

  • 이시웅;손장열
    • 대한설비공학회지:설비저널
    • /
    • 제17권3호
    • /
    • pp.249-256
    • /
    • 1988
  • The purpose of this paper is to research the estimations of the indoor natural temperature in a case of the earth sheltered space and the 1st basement room in comparison with a conventional housing. The result of this study can be summerized as follows: The natural temperature of the earth sheltered house Summer : $${\theta}es=27.0+1.65sin(2{\pi}/24{\cdot}T-1.34)$$ Winter : $${\theta}ew=11.5+1.15sin(2{\pi}/24{\cdot}T-1.61)$$ The natural temperature of the 1st basement space Summer : $${\theta}us=25.5+1.00sin(2{\pi}/24{\cdot}T-1.72)$$ Winter : $${\theta}uw=13.9+1.10sin(2{\pi}/24{\cdot}T-2.29)$$ From the results of the stated above, we can calculate the cooling and heating load in the earth sheltered house and the underground space exactly and easily at Taejeon City.

  • PDF

지하수로부터의 실내 라돈오염시 인체노출평가 (Assessment of Human Exposures to Indoor Radon Released from Groundwater)

  • 유동한;김상준;양지원
    • 한국대기환경학회지
    • /
    • 제17권3호
    • /
    • pp.241-249
    • /
    • 2001
  • A report by the National Research Council in the United States suggested that many lung cancer deaths each year are associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundation. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the assessment of a exposure to radon released from the groundwater into indoor air. At first, a 3-compartment model is describe the transfer and distribution if radon released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such radon for adults based on two sets of exposure scenarios, Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과 (Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma)

  • 백남원;허성민;이일영
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

Towards Quantitative Assessment of Human Exposures to Indoor Radon Pollution from Groundwater

  • Donghan Yu;Lee, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E2호
    • /
    • pp.43-51
    • /
    • 2001
  • A report by the national research council in the United States suggested that many lung cancer deaths each year be associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundations. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the quantitative assessment of human exposures to radon released from the groundwater into indoor air. At first, a three-compartment model is developed to describe the transfer and distribution of radon released from groundwater in a house through showering, washing clothes, and flushing toilets. Then, to estimate a daily human exposure through inhalation of such radon for an adult. a physiologically-based pharmacokinetic(PBPK) model is developed. The use of a PBPK model for the inhaled radon could provide useful information regarding the distribution of radon among the organs of the human body. Indoor exposure patterns as input to the PBPK model are a more realistic situation associated with indoor radon pollution generated from a three-compartment model describing volatilization of radon from domestic water into household air. Combining the two models for inhaled radon in indoor air can be used to estimate a quantitative human exposure through the inhalation of indoor radon for adults based on two sets of exposure scenarios. The results obtained from the present study would help increase the quantitative understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

안트라사이트와 버미큘라이트를 혼입한 산화마그네슘 경화체의 흡착특성 (Adsorption properties of magnesium oxide matrix using anthracite and vermiculite)

  • 김대연;편수정;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.224-225
    • /
    • 2018
  • Modern people are more interested in the indoor environment as they spend more time indoors than in the past. Among the air pollutants in the indoor air, ladon gas is a colorless, tasteless, odorless, inert gas produced by nuclear decomposition of naturally occurring uranium in rocks and soils. It has been proven that ladon gas is introduced into the room through cracks on the floor of the building or basement wall, and it causes various diseases such as lung cancer when exposed to radon during human breathing. The US Environmental Protection Agency (EPA) specifies 4pCi / L as a necessary measure for radon, and the Korea Environmental Protection Agency has implemented comprehensive indoor radon management measures since 2007. Therefore, in this study, we intend to adsorb and reduce radon in indoor air pollutants.

  • PDF

6, 10, 17 GHz 반지하 실내 복도 환경의 전파 특성 분석 (Analysis of Propagation Characteristics in 6, 10, and 17 GHz Semi-Basement Indoor Corridor Environment)

  • 이성훈;조병록
    • 한국전자통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.555-562
    • /
    • 2022
  • 4차 산업혁명시대에 반지하 실내 복도 환경에서 새로운 전파 수요를 발굴하기 위해 본 논문에서는 주파수 6, 10, 17 GHz의 전파 특성에 대한 측정 및 분석하였다. 측정한 실내 내부 환경은 3면의 강의실과 외면의 유리창으로 구성되어있는 일자형 복도이다. 본 연구는 이러한 환경에 맞게 측정 시나리오 개발과 측정 시스템을 구성하였다. 송신 안테나는 고정하고 수신 안테나 위치의 거리에 따라 가시선 환경에서 주파수 영역과 시간영역 전파 특성을 측정하여 분석 하였다. 주파수 영역은 FI(: Floating intercept) 경로 손실 모델의 매개변수와 R-squared 값의 0.5 이상에 대한 신뢰도를 얻었다. 또한, 시간 영역은 RMS(: Root mean square) 지연 확산과 K-factor의 누적 확률에서 6 GHz는 전파 전달도가 높고, 17 GHz는 전파 전달도가 낮은 결과를 얻었다. 이러한 연구 결과는 반지하 실내 복도 환경에서 WIFI 6 이상이나 5G 이상에 대해 초 연결과 초 지연 인공지능 서비스를 제공하는데 효과가 있을 것이다.

서울대학교 관악캠퍼스 지역에서의 실내 라돈농도 분포 (Indoor Radon Levels in the Room of Kwanak Campus, Seoul National University)

  • 제현국;강치구;전효택
    • 자원환경지질
    • /
    • 제31권5호
    • /
    • pp.425-430
    • /
    • 1998
  • The results of radon $(^{222}Rn)$ concentrations and working levels (WL) for forty rooms in Kwanak Campus, Seoul National University on granite bedrock of Jurassic age showed that radon concentration have mean value of 3.0 pCi/L and 0.011 for working level. A number of rooms where these values exceed the EPA's action level are five (13%). It was also suggested that indoor basement rooms in poor ventilation condition can be classified as extremely high radon risk zone having more than 4 pCi/L and 0.020 WL. It was proved that inflow of soil-gas was a primary factor that governs indoor radon level by comparison of soil-gas radon concentrations with indoor radon concentrations.

  • PDF