• 제목/요약/키워드: Indirect evaluation method

검색결과 183건 처리시간 0.026초

내부 매입형 철골조로 보강된 철근콘크리트 건물의 내진 성능평가 (Seismic Performance Evaluation of Reinforced Concrete Buildings Strengthened by Embedded Steel Frame)

  • 김선웅;이경구
    • 한국지진공학회논문집
    • /
    • 제24권1호
    • /
    • pp.29-37
    • /
    • 2020
  • This study is to investigate the effect of a retrofitted reinforced concrete frame with non-seismic details strengthened by embedded steel moment frames with an indirect joint, which mitigates the problems of the direct joint method. First, full-scale experiments were conducted to confirm the structural behavior of a 2-story reinforced concrete frame with non-seismic details and strengthened by a steel moment frame with an indirect joint. The reinforced concrete frame with non-seismic details showed a maximum strength of 185 kN at an overall drift ratio of 1.75%. The flexural-shear failure of columns was governed, and shear cracks were concentrated at the beam-column joints. The reinforced concrete frame strengthened by the embedded steel moment frames achieved a maximum strength of 701 kN at an overall drift ratio of 1.5% so that the maximum strength was about 3.8 times that of the specimen with non-seismic details. The failure pattern of the retrofitted specimen was the loss of bond strength between the concrete and the rebars of the columns caused by a prying action of the bottom indirect joint because of lateral force. Furthermore, methods are proposed for calculation of the specified strength of the reinforced concrete frame with non-seismic details and strengthened by the steel moment frame with the indirect joint.

4지 신호교차로에서 효율적 자전거 교통류 처리방안 연구 (A Study on Efficient Management of Bicycle Traffic Flow at Four-Legged Intersections)

  • 목승준;김응철;허희범
    • 한국도로학회논문집
    • /
    • 제15권3호
    • /
    • pp.177-189
    • /
    • 2013
  • PURPOSES: This study aims to suggest a proper left-turn treatment method for the bicycle traffic flow at four-legged intersections. METHODS: Four types of crossing methods are proposed and analyzed : (1) indirect left turn, (2) direct left turn, (3) direct left turn on a Bike Box, and (4) direct left turn on bike left turn lane. The VISSIM simulation tests were conducted based on forty-eight operation scenarios prepared by varying vehicle and bicycle traffic volumes. RESULTS : The results from the four-legged signalized intersections suggest that (1) the indirect left turn is appropriate when vehicle demand is high, (2) the direct left turn is efficient on most traffic situation but the safety is a concern, (3) the direct left turn on a Bike Box is appropriate when bicycle demand is high while vehicle demand is not, and (4) the direct left turn on a bike left turn lane is appropriate when both vehicle and bicycle demand are low. CONCLUSIONS : The direct left turn of bicycle provides more efficiency than the indirect left turn at the four-legged intersections but to apply the methods and to study more, advanced evaluation methods, related law, and insurance programs are needed.

초음파 측정법을 이용한 콘크리트 균열보수재의 충전성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Injection-ability for Concrete Crack-Repair Materials by using Ultrasonic Pulse Measurement Method.)

  • 이상현;이한승;박성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.515-518
    • /
    • 2005
  • A concrete is easy to happen crack. So it requires crack-repair work to solve quality deteriorations of a building because of cracks. When crack is filled with crack-repair materials, it is difficult to find out how depth it was injected. So in this study we evaluated the injection depth with using indirect and oblique methods, ultrasonic pulse measurement method of NDT. The results of this study showed that both methods are possible to evalute penetration depth of crack-repair materials and indirect methods is thought to be more useful one than obliqure one.

  • PDF

전술데이터링크 연동시스템의 개념적 소프트웨어 아키텍처 설계 (A Design of a Conceptual Software Architecture for Inter-operational System of Tactical Data Link)

  • 남재민;윤희병
    • 한국국방경영분석학회지
    • /
    • 제31권2호
    • /
    • pp.105-115
    • /
    • 2005
  • To ensure interoperability among TADILs, we need inter-operational system of tactical data link that allows sharing of specific, planned information among different TADILs. In this paper, we have proposed the design of a conceptual software architecture of inter-operational system. For developing of a conceptual software architecture, we analyze the actual condition of ADSI used in the US military and identify functions and quality-attributes. Based on these factors, we design the conceptual software architecture for inter-operational system of tactical data link using Attribute-Driven Design(ADD) method. ADD is consist of three phases - choose the module to decompose, refine the module, repeat the steps for every module that needs further decomposition. To evaluate of ADD results, we apply the Software Architecture Analysis Method(SAAM) which is consist of making evaluation scenarios, choosing indirect scenarios, evaluation scenarios' interaction, and creating an overall evaluation. Through the evaluation, we verify the conceptual software architecture of inter-operational system.

간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구 (Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Trust Evaluation Metrics for Selecting the Optimal Service on SOA-based Internet of Things

  • Kim, Yukyong
    • 한국소프트웨어감정평가학회 논문지
    • /
    • 제15권2호
    • /
    • pp.129-140
    • /
    • 2019
  • In the IoT environment, there is a huge amount of heterogeneous devices with limited capacity. Existing trust evaluation methods are not adequate to accommodate this requirement due to the limited storage space and computational resources. In addition, since IoT devices are mainly human operated devices, the trust evaluation should reflect the social relations among device owners. There is also a need for a mechanism that reflects the tendency of the trustor and environmental factors. In this paper, we propose an adaptable trust evaluation method for SOA-based IoT system to deal with these issues. The proposed model is designed to minimize the confidence bias and to dynamically respond to environmental changes by combining direct evaluation and indirect evaluation. It is expected that it will be possible to secure trust through quantitative evaluation by providing feedback based on social relationships.

문서세단기 성능평가방법의 표준화에 관한 연구 (A Study on Standard of Performance Evaluation for Paper Shredder)

  • 이동규;유송민;이위로;노대호;김민호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2004
  • The purpose of this study is to introduce the standard of the durability and evaluation method for paper shredder. The major evaluation criteria include shredding capability, shredding blade (or cutter) hardness and edge roughness, and durability. Due to the difficulties in assessing the durability directly, performance deterioration of the shredder was assessed by measuring the torque variation along with the variation in shredded chip size and load, thereby proposing the indirect method of assessing the paper shredder durability.

  • PDF

SIMULATOR FOR EVALUATION OF VARIOUS FUZZY CONTROL METHODS

  • Hayashi, Kenichiro;Muta, Itsuya;Hoshino, Tsutomu;Ohtsubo, Akifumi
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.949-952
    • /
    • 1993
  • As well-known, fuzzy control has been recognized to be of great usefulness in many engineering fields. However, the present design methods of fuzzy control systems depend on trial and error the thing that limits its usefulness. Therefore, an effective and convenient support tools for design and evaluation are greatly needed as well as the establishment of the design methods and guidling. From these backgrounds, we have developed a fuzzy control simulator[1, 2] which has various fuzzy control methods such as "direct method", "indirect method" and "fuzzy-PID method". This paper deals especially with the "direct method" function of the simulator. The simulator was developed for personal computers and programed in C language.

  • PDF

초음파 비파괴시험법을 이용한 데크재의 현장평가 (Ultrasonic Nondestructive On-Site Evaluation of Decks in-Service)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권4호
    • /
    • pp.486-493
    • /
    • 2015
  • 설치된 데크재에 대한 성능을 평가하기 위하여 초음파 비파괴시험법을 사용하였다. 먼저 3종류의 데크재에 대해 트랜스듀서의 배치에 따른 직접법과 간접법간의 측정방법간의 차이를 검증하였으며 두 번째로 설치된 데크재의 사용시간의 경과에 따른 초음파속도를 측정 비교하였다. 마지막으로 데크재의 사용수명을 파악하기 위하여 사용시간의 경과에 따른 초음파속도의 변화를 조사하였다. 시험결과 직접법과 간접법간의 측정방법간의 차이는 없는 것으로 나타났으며 직접법에 대한 간접법의 비율은 1.02와 1.05로 각각 나타났다. 설치된 데크재에서 시간의 경과에 따라 초음파 속도는 감소하였으며 이들 간의 관계는 선형으로 나타났다. 시험결과로부터 초음파 비파괴시험법은 설치된 데크재의 유지보수에 관한 효율적인 수단이 될 수 있을 것으로 생각된다.

Criteria for clinical translucency evaluation of direct esthetic restorative materials

  • Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • 제41권3호
    • /
    • pp.159-166
    • /
    • 2016
  • The purpose of this review was to suggest practical criteria for the clinical translucency evaluation of direct esthetic restorative materials, and to review the translucency with these criteria. For the evaluation of reported translucency values, measuring instrument and method, specimen thickness, background color, and illumination should be scrutinized. Translucency parameter (TP) of 15 to 19 could be regarded as the translucency of 1 mm thick human enamel. Visual perceptibility threshold for translucency difference in contrast ratio (${\Delta}CR$) of 0.07 could be transformed into ${\Delta}TP$ value of 2. Translucency differences between direct and indirect resin composites were perceivable (${\Delta}TP>2$). Universal and corresponding flowable resin composites did not show perceivable translucency differences in most products. Translucency differed significantly by the product within each shade group, and by the shade group within each product. Translucency of human enamel and perceptibility threshold for translucency difference may be used as criteria for the clinical evaluation of translucency of esthetic restorative materials.