• 제목/요약/키워드: Indirect bonding technique

검색결과 22건 처리시간 0.029초

Experimental investigation on CFRP-to-concrete bonded joints across crack

  • Anil, Ozgur;Belgin, Cagatay M.;Kara, M. Emin
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.1-18
    • /
    • 2010
  • Bonding of carbon fiber reinforced polymer (CFRP) composites has become a popular technique for strengthening concrete structures in recent years. The bond stress between concrete and CFRP is the main factor determining the strength, rigidity, failure mode and behavior of a reinforced concrete member strengthened with CFRP. The accurate evaluation of the strain is required for analytical calculations and design processes. In this study, the strain between concrete and bonded CFRP sheets across the notch is tested. In this paper, indirect axial tension is applied to CFRP bonded test specimen by a four point bending tests. The variables studied in this research are CFRP sheet width, bond length and the concrete compression strength. Furthermore, the effect of a crack- modeled as a notch- on the strain distribution is studied. It is observed that the strain in the CFRP to concrete interface reaches its maximum values near the crack tips. It is also observed that extending the CFRP sheet more than to a certain length does not affect the strength and the strain distribution of the bonding. The stress distribution obtained from experiments are compared to Chen and Teng's (2001) analytical model.

즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교 (The comparison of microtensile bond strength with immediate and delayed dentin sealing)

  • 이흥배;한종현;심준성;김선재
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.372-380
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)을 시행한 경우와 지연 상아질 봉쇄 (delayed dentin sealing ; DDS)를 시행한 경우를 비교하고, 지연 상아질 봉쇄 시 상아질 접착제를 먼저 중합한 경우와 복합레진과 함께 중합한 경우에 있어서 상아질과 복합레진의 결합강도를 비교하는 것이다. 재료 및 방법: 사람의 건전한 대구치 20개의 치관부를 삭제하여 상아질 표면을 노출시켰다. 상아질 접착 후 바로 복합레진을 축조하는 과정에서 군을 4 가지로 나누었다. 대조군은 주수 하에 model trimmer를 이용하여 치관부 삭제 후 바로 2-step etch-and-rinse dentin bonding agent (ONE-STEP, Bisco, USA)를 이용하여 상아질 접착을 시행하고 복합레진 (RENEW, Bisco, USA)을 수복하였다. 실험군 A는 치아 삭제 후, Fermit을 이용한 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 B는 치아 삭제 후, 상아질 접착제 도포 및 중합하고 임시수복을 시행하여 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 C는 치아 삭제 후, 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후, 상아질 접착제를 도포 및 중합하고, 레진을 축조 및 중합하였다. 각 치아를 단면적 1 $mm^2$, 길이 10-12 mm의 막대형 시편으로 절단하여, 미세인장 결합강도를 측정하였다. 측정된 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며, 사후 검증은 Scheffe test를 이용하여 분석하였다. 연구결과: 본 실험의 결과는 다음과 같다. 1. 치아 삭제 후 별도의 상아질 접착 시행 없이 임시수복하고, 레진 축조 전 상아질 접착을 도포 후 별도의 중합과정 없이 레진과 함께 중합할 경우, 상아질과의 미세인장 결합강도는 유의하게 낮은 값을 보였다 (P < .01). 2. 치아 삭제 및 임시 수복 기간 후, 상아질 접착제를 먼저 중합하고 복합 레진을 수복하는 경우와 치아 삭제 후 상아질 접착을 시행하고 수복물 장착 시 상아질 접착을 재시행하는 경우 간의 상아질에 대한 결합강도의 차이는 없었다 (P > .05).

An effect of immediate dentin sealing on the shear bond strength of resin cement to porcelain restoration

  • Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.39-45
    • /
    • 2010
  • PURPOSE. The aim of this study was to determine differences in shear bond strength to human dentin using immediate dentin sealing (IDS) technique compared to delayed dentin sealing (DDS). MATERIALS AND METHODS. Forty extracted human molars were divided into 4 groups with 10 teeth each. The control group was light-cured after application of dentin bonding agent ($Excite^{(R)}$ DSC) and cemented with $Variolink^{(R)}$. II resin cement. IDS/SE (immediate dentin sealing, $Clearfil^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, $Adapter^{TM}$ Single Bond 2) were light-cured after application of dentin bonding agent ($Clearfil^{TM}$ SE Bond and $Adapter^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. Specimens were cemented with $Variolink^{(R)}$. II resin cement. Dentin bonding agent ($Excite^{(R)}$. DSC) was left unpolymerized until the application of porcelain restoration. Shear strength was measured using a universal testing machine at a speed of 5 mm/min and evaluated of fracture using an optical microscope. RESULTS. The mean shear bond strengths of control group and IDS/SE group were not statistically different from another at 14.86 and 11.18 MPa. Bond strength of IDS/SE group had a significantly higher mean than DDS group (3.14 MPa) (P < .05). There were no significance in the mean shear bond strength between IDS/SB (4.11 MPa) and DDS group. Evaluation of failure patterns indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS were interfacial. CONCLUSION. When preparing teeth for indirect ceramic restoration, IDS with $Clearfil^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

브라켓 부착시 레진 베이스의 두께에 따른 전단결합강도와 파절양상에 관한 연구 (SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE THICKNESS OF RESIN BASE IN BRACKET BONDING)

  • 김재혁;황현식
    • 대한치과교정학회지
    • /
    • 제28권4호
    • /
    • pp.659-668
    • /
    • 1998
  • 본 연구는 브라켓 간접부착술식시 레진 베이스의 두께에 따른 전단결합강도와 파절양상을 비교함으로써 레진 베이스 두께 증가시 전단결합강도의 저하여부를 평가하기 위하여 시행되었다. 소의 하악 절치를 포매하여 만든 레진블럭에 micromanipulator를 사용하여 치면과 브라켓 기저면 사이의 광중합형 접착제가 0.0, 0.5, 1.0, 1.5, 2.0 mm두께가 되도록 각각 브라켓을 부착한 다음 만능물성시험기를 이용하여 치면으로부터 하중 위치까지의 거리를 일정하게 유지하면서 레진 베이스의 두께를 증가시킨 경우와 레진 베이스 두께의 증가와 함께 치면으로부터 하중 위치까지의 거리를 증가시킨 경우로 나누어 전단결합강도를 측정하고 파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 치면으로부터 하중 위치까지의 거리를 일정하게 유지한 경우 레진 베이스 두께의 증가와 함께 브라켓 기저부로부터 하중 위치까지의 거리가 감소함에 따라 전단결합강도가 유의하게 증가하였다. 2. 레진 베이스 두께의 증가와 함께 치면으로부터 하중 위치까지의 거리를 증가시킨 경우 전단결합강도가 감소하는 것으로 나타났으나 그 유의차는 미미하였다. 3. 접착제 잔류지수를 이용하여 레진 베이스의 두께에 따른 파절양상을 비교 관찰한 결과 유의한 차이를 보이지 않았다. 이상의 실험결과를 볼 때 브라켓 부착시 레진 베이스의 두께에 따른 전단결합강도는 브라켓 기저부로부터 하중 위치까지의 거리가 증가함에 따라 감소하는 반면 레진 베이스 두께의 영향은 크게 받지 않는 것으로 나타났다.

  • PDF

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • 대한치과교정학회지
    • /
    • 제47권4호
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.

REPORT ON A CASE TREATED WITH LINGUAL MULTIBRACKET APPLIANCE

  • Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제26권6호
    • /
    • pp.705-715
    • /
    • 1996
  • The lingual multibracket appliance was developed to overcome the unesthetic nature of traditional fixed orthodontic labial appliances; however, treatment with this appliance was regarded as very difficult as well as a time-consuming. Recently, these problems have been reduced because of advances in lingual bracket systems, improved indirect bonding technique and the development of more flexible wires. There has been a marked increase in the number of adults desiring orthodontic treatment over recent years and many of these patients tend to seek invisible orthodontic appliances due to esthetic reasons. Although the lingual multibracket treatment is not ideal, this form of treatment is currently the best option for the patients with esthetic concerns. Here, I would like to present a case treated successfully with lingual multibracket appliance.

  • PDF

간접 코팅과 롤 접합을 이용한 의료용 스플린트 제작 및 공정기술 개발 (Development of the Splint Manufacturing Process Using Indirect Coating and Roll Bonding)

  • 하경호;강대민;이정희;곽재섭
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.1-6
    • /
    • 2019
  • With the increase in number of the athletic population and elderly demographic, the demand for orthopedic splints, which are used to support a damaged body, has rapidly increased. Current splints mainly consist of inner and outer parts, which are multiple fabrics covered with polyurethane and nonwoven fabrics, respectively. However, the laminated materials with directly applied pre-polymer coating lead to a high defect rate because of the uneven thickness on the surface. Thus, this study proposes an indirect coating method using a precise clearance controller, which enables the even application of the coating material on multiple inner parts while maintaining a constant thickness. In addition, a roll-to-roll (R2R) technique is applied instead of the sewing mechanism to bond the inner and outer materials together and enhance the productivity in the final stage. In the advanced methods, there is a storage tank that contains polyurethane, a clearance controller, and pairs of rollers in the upper and lower rows. To improve the quality of the products and optimize the equipment, three controllable factors are determined: the viscosity of polyurethane, angle of the gap controller and number of pairs of rollers in the R2R system.

원격 플라즈마 화학기상증착법에 의해 중합된 아크릴산 필름의 XPS 분석 (XPS Analysis of Acrylic Acid Films Polymerized by Remote Plasma-Enhanced Chemical Vapor Deposition)

  • 김성훈;서문규
    • 공업화학
    • /
    • 제20권5호
    • /
    • pp.536-541
    • /
    • 2009
  • 플라즈마 중합 아크릴산 필름을 원격 플라즈마 방식으로 Si과 KBr 기판 위에 증착하였다. 플라즈마 출력, 반응 압력, 간접 플라즈마 방식이 필름의 성장속도, 화학적 구조 및 화학 결합 상태 등에 미치는 영향을 조사하였다. 화학 구조와 화학적 상태는 FT-IR, XPS 분석과 curve fitting 기법으로 분석하였다. 플라즈마 출력에 따른 필름의 성장속도는 100 W에서 포화값을 보이지만, 압력에 대해서는 300 mtorr에서 최대값을 나타내었다. 플라즈마 출력을 높이거나 압력을 낮추면 단위 입자들에게 가해지는 에너지 값(W/FM)이 증가하여 아크릴산 분자의 파괴가 촉진되었다. XPS curve fitting 분석 결과, W/FM값이 커질수록 카르복실 COO 결합은 감소하지만 에테르 C-O 결합과 카보닐 C=O 결합은 증가하여 서로 반대의 경향을 보임을 확인하였다.

Fiber Reinforced Inlay Adhesion Bridge

  • Cho, Lee-Ra;Yi, Yang-Jin;Song, Ho-Yong
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.366-374
    • /
    • 2000
  • FRC/ceromer system provides the clinician with a durable, flexible, and esthetic alternative to conventional porcelain fused to metal crowns. FRC is the matrix which is silica-coated and embedded in a resin matrix. The ceromer material which is a second generation indirect composite resin contains silanized, microhybrid inorganic fillers embedded in a light-curing organic matrix. FRC/ceromer restoration has a several advantages: better shock absorption, less wear of occluding teeth, translucency, color stability, bonding ability to dental hard tissues, and resiliency. It has versatility of use including inlay, onlay, single crown, and esthetic veneers. With adhesive technique, it can be used for single tooth replacement in forms of inlay adhesion bridge. In single tooth missing case, conventional PFM bridge has been used for esthetic restoration. However, this restoration has several disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures. Inlay adhesion bridge with FRC/ceromer would be a good alternative treatment plan. This article describes a cases restored with Targis/Vectris inlay adhesion bridge. Tooth preparation guide, fabrication procedure, and cementation procedure of this system will be dealt. The strength/weakness of this restoration will be mentioned, also. If it has been used appropriately in carefully selected case, it can satisfy not only dentist's demand of sparing dental hard tissue but also patient's desire of seeking a esthetic restorations with a natural appearance.

  • PDF

설측브라켓 부착시 위치오차에 관한 연구 (THE POSITIONING ERRORS IN BONDING LINGUAL BRACKETS)

  • 최준규;황현식;김종철
    • 대한치과교정학회지
    • /
    • 제28권1호
    • /
    • pp.99-111
    • /
    • 1998
  • 본 연구는 설측브라켓 부착시 부착방법에 따른 위치오차를 알아보기 위하여 시행되었다. 교정환자 20명의 초진시 석고모형을 연구대상으로 하여, 초진모형의 각 치면에 긴밀하게 브라켓을 부착하는 방법, 치아재배열을 시행한 후 치면에 긴밀하게 부착하는 방법 그리고 치아재배열을 시행하고 이상호선을 제작한 후 브라켓을 결찰하여 부착하는 passive bracketing의 3가지 방법으로 브라켓을 부착한 후 각 방법으로 부착된 브라켓의 위치오차를 측정 및 비교하여 다음과 같은 결과를 얻었다. 1. 각도오차 분석결과, 치아재배열을 시행하지 않은 경우 상악 제1소구치와 하악견치의 위치오차가 타 방법에 비하여 크게 나타났으며, passive bracketing을 시행하지 않은 경우 상악 중절치, 하악 제1$\cdot$제2소구치에서 그 위치오차가 크게 나타났다. 2. 토크오차 분석결과, 치아재배열을 시행하지 않은 경우 하악 제2소구치의 위치오차가 타 방법에 비해 크게 나타났으며 passive bracketing을 시행하지 않은 경우 상악 전 치아와 하악 제1$\cdot$제2소구치에서 그 위치오차가 크게 나타났다. 3. 회전오차 분석결과, passive bracketing을 시행하지 않은 경우 상악 중절치간, 하악 중절치간, 하악 측절치와 중절치 사이 그리고 하악 견치와 측절치 사이에서 그 위치오차가 크게 나타났다. 4. 내외오차 분석결과, 치아재배열을 시행하지 않은 경우 상악 견치와 측절치 사이에서 위치오차가 타 방법에 비해 크게 나타났으며, passive bracketing을 시행하지 않은 경우 상악 중절치간, 측절치와 중절치 사이, 제1$\cdot$제2소구치 사이, 하악 측절치와 중절치 사이, 견치와 측절치 사이에서 그 위치오차가 크게 나타났다. 본 연구 결과는 설측교정술의 경우 브라켓 간접부착 술식을 사용하더라도 상당량의 위치오차가 나타나며, 이는 passive bracketing으로 줄일 수 있음을 시사하였다.

  • PDF