• Title/Summary/Keyword: Indirect Bonding

Search Result 87, Processing Time 0.022 seconds

Spectroscopic Analysis of the Remote-plasma-polymerized Methyl Methacrylate Film (원격 플라즈마 중합된 메틸메타크릴레이트 필름의 분광학적 분석)

  • Seomoon, Kyu
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.49-54
    • /
    • 2021
  • Plasma-polymerized methyl methacrylate (MMA) thin films were synthesized by remote plasma, and effects of plasma power, reaction pressure and direct-indirect plasma on the growth rate and chemical bonding were investigated with alpha-step, FT-IR, XPS and Langmüir probe method. As the plasma power and pressure increased, the tendency of growth rate showed maximum value at a certain range. FT-IR and XPS analyses revealed that composition ratio of C/O and hydrocarbon (C-C) % in the deposited films increased with plasma power, but ester (COO) C % decreased with it. Direct plasma method was effective for fast growth rate, but indirect plasma method was favorable for maintaining the chemical structure of MMA.

Comparison of shearbond strength between metal and indirect resin according to the different conditionings (표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구)

  • Choi, Su-Young;Choi, Hyunmin;Moon, Hong-Seok;Shim, June-Sung;Park, Young-Bum;Lee, Geun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.264-271
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. Materials and methods: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. Results: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). Conclusion: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE THICKNESS OF RESIN BASE IN BRACKET BONDING (브라켓 부착시 레진 베이스의 두께에 따른 전단결합강도와 파절양상에 관한 연구)

  • Kim, Jae-Hyuk;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.659-668
    • /
    • 1998
  • The purpose of this study was to evaluate the possibility of the decrease of bond strength due to increased thickness of resin base in indirect bracket bonding technique. Metal brackets were bonded to the resin blocks involving bovine lower incisors and the thickness of resin bases was increased by increments of 0.5 mm from 0.0 mm to 2.0 mm. They were divided into two groups, one group is that the thickness of resin base was increased but the loading point from the tooth surface was maintained constantly, the other group is that the loading point from the tooth surface and the resin base thickness were increased concomitantly. The shear bond strength was tested on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI). The results were as follows: 1. When the distance from the tooth surface to the loading point was maintained constantly, shear bond strength was increased significantly according to the decrease of distance from the bracket base to the loading point and the increase of resin base thickness. 2. When the distance from the tooth surface to the loading point and the resin base thickness were increased concomitantly, shear bond strength was decreased according to the increase of resin base thickness but significant differences were ignorable. 3. There were no significant differences in ARI scores according to the change in the thickness of resin base. The results of the present study indicated that shear bond strength was not much affected by the thickness of resin base, whereas was decreased according to the increase of distance from bracket base to the loading point.

  • PDF

The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin

  • Su, Naichuan;Yue, Li;Liao, Yunmao;Liu, Wenjia;Zhang, Hai;Li, Xin;Wang, Hang;Shen, Jiefei
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.214-223
    • /
    • 2015
  • PURPOSE. To measure the surface loss of dental restorative zirconia and the short-term bond strength between an indirect composite resin (ICR) and zirconia ceramic after various sandblasting processes. MATERIALS AND METHODS. Three hundred zirconia bars were randomly divided into 25 groups according to the type of sandblasting performed with pressures of 0.1, 0.2, 0.4 and 0.6 MPa, sandblasting times of 7, 14 and 21 seconds, and alumina powder sizes of 50 and $110{\mu}m$. The control group did not receive sandblasting. The volume loss and height loss on zirconia surface after sandblasting and the shear bond strength (SBS) between the sandblasted zirconia and ICR after 24-h immersion were measured for each group using multivariate analysis of variance (ANOVA) and Least Significance Difference (LSD) test (${\alpha}$=.05). After sandblasting, the failure modes of the ICR/zirconia surfaces were observed using scanning electron microscopy. RESULTS. The volume loss and height loss were increased with higher sandblasting pressure and longer sandblasting treatment, but they decreased with larger powder size. SBS was significantly increased by increasing the sandblasting time from 7 seconds to 14 seconds and from 14 seconds to 21 seconds, as well as increasing the size of alumina powder from $50{\mu}m$ to $110{\mu}m$. SBS was significantly increased from 0.1 MPa to 0.2 MPa according to the size of alumina powder. However, the SBSs were not significantly different with the sandblasting pressure of 0.2, 0.4 and 0.6 MPa. The possibilities of the combination of both adhesive failure and cohesive failure within the ICR were higher with the increases in bonding strength. CONCLUSION. Based on the findings of this study, sandblasting with alumina particles at 0.2 MPa, 21 seconds and the powder size of $110{\mu}m$ is recommended for dental applications to improve the bonding between zirconia core and ICR.

THE EFFECT OF VARIOUS BONDING SYSTEMS ON THE MICROTENSILE BOND STRENGTH OF IMMEDIATE AND DELAYED DENTIN SEALING (수종의 상아질 접착시스템이 즉시 및 지연 상아질 봉쇄의 미세인장결합강도에 미치는 영향)

  • Ha, Jin-Hee;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.526-536
    • /
    • 2008
  • The purpose of this study was to compare the effect of various dentin bonding systems on microtensile bond strength of immediate dentin sealing (IDS) and delayed dentin sealing (DDS). Eighteen extracted permanent molars were used in this study. The teeth for DDS group were restored with a provisional restorations, and immersed in saline solution for 1 week, and divided into 3 subgroups according to various dentin bonding adhesives; SB subgroup (3 step total-etch adhesive), SE subgroup (2 step self-etch adhesive), XE subgroup (1 step self-etch adhesive). In IDS group, the teeth were divided into 3 subgroups, and applied with bonding adhesives as in DDS group. The teeth were restored with provisional restorations, and immersed in saline solution for 1 week. Indirect composite disc was cemented with resin cement, and all specimens were subjected to microtensile bond strength. The data were statistically analyzed with oneway ANOVA and Student t-test. The results were as follows: 1. The IDS group showed significantly higher ${\mu}TBS$ than DDS group in 3 step total-etch and 2 step selfetch adhesive (p < 0.05). 2. In IDS and DDS group, 3 step total-etch adhesive showed the highest ${\mu}TBS$ value, followed by 2 step self-etch, and 1 step self-etch adhesive. In IDS group, the ${\mu}TBS$ value for 1 step self-etch adhesive was significantly different from those of the other subgroups (p < 0.05), and in DDS group, there were statistical differences in all subgroup (p < 0.05). 3. Failure modes of tested dentin bonding adhesives were mostly mixed failure and only 1 step self-etch adhesive showed adhesive failure.

MICROLEAKAGE AND MARGINAL ADAPTATION OF POSTERIOR COMPOSITE RESIN RESTORATIONS ACCORDING TO RESTORATIVE TECHNIQUE (수복에 따른 구치부 복합레진 수복물의 변연부 미세누출 및 적합도)

  • Yang, In-Seo;Shin, Dong-Hoo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.334-346
    • /
    • 1997
  • Incidence of using esthetic composite resin in the posterior area is increasing but there were lots of inconsistent reports about their microleakage and marginal adaptation. The purpose of this study was to evaluate the differences of microleakage and marginal adaptation according to restorative techniques. 30 cavities with enamel gingival margin were prepared and restored with 3 types of composite resin [Z-100($Scotchbond^{TM}$ MP), AELITEFIL ($Onestep^{TM}$), Her culite XRV(Fuji BOND LC)] in direct technique and another 30 cavities were restored with preformed CR inlays and 3 different modern resin and resin-modified GI cements (Superbond C&B, Choice, Fuji Duet). Samples were chemically stressed in 75% ethanol for 24 hours and were thermocycled (5-$55^{\circ}C$(500 times. The degree of microleakage through proximal and gingival margins was examined by 1 % MB dye and the degree of marginal adaptation by examining the margins via SEM. The following results were obtained ; 1. In direct groups, Herculite XRV [Fuji BOND LC, 35.13 (15.50) %] group showed statistically different, less microleakage than Z-100 [$Scotchbond^{TM}$ MP, 72.91 (16.91 %] group and AELITEFIL [One-step, 93.73 (13.66) %] group (p<0.05). 2. In indirect groups, the degree of microleakage in Mean(S.D.) were: Super bond C & B [39.00 (24.35) %], Choice [57.19 (33.80) %], Fuji Duet [58.22 (40.36) %]. But there was no significant difference. 3. There was no significant difference between resin cement and resin-modified GI cement. 4. There were gaps at the interface with the tooth structure, but no gap was seen at the interface with restoration in all specimens. 5. In direct groups, Herculite XRV(Fuji BOND LC) group made little gap compared with other groups, but 40-$50{\mu}m$ thickness of bonding agent, Fuji BOND LC, looked like a cement used in indirect technique. 6. All indirect groups showed a variety of cement thickness, from less than $20{\mu}m$ to over $100{\mu}m$ and that dimension of buccal/lingual margin was less than that of gingival margin.

  • PDF

Development of the Splint Manufacturing Process Using Indirect Coating and Roll Bonding (간접 코팅과 롤 접합을 이용한 의료용 스플린트 제작 및 공정기술 개발)

  • Ha, Kyoung-Ho;Kang, Dae-Min;Lee, Jung-Hee;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.2
    • /
    • pp.1-6
    • /
    • 2019
  • With the increase in number of the athletic population and elderly demographic, the demand for orthopedic splints, which are used to support a damaged body, has rapidly increased. Current splints mainly consist of inner and outer parts, which are multiple fabrics covered with polyurethane and nonwoven fabrics, respectively. However, the laminated materials with directly applied pre-polymer coating lead to a high defect rate because of the uneven thickness on the surface. Thus, this study proposes an indirect coating method using a precise clearance controller, which enables the even application of the coating material on multiple inner parts while maintaining a constant thickness. In addition, a roll-to-roll (R2R) technique is applied instead of the sewing mechanism to bond the inner and outer materials together and enhance the productivity in the final stage. In the advanced methods, there is a storage tank that contains polyurethane, a clearance controller, and pairs of rollers in the upper and lower rows. To improve the quality of the products and optimize the equipment, three controllable factors are determined: the viscosity of polyurethane, angle of the gap controller and number of pairs of rollers in the R2R system.

Effect of Social Relation on Digital Device Usage: A Social Capital Perspective (개인의 사회적 관계가 디지털 기기 활용에 미치는 영향에 대한 연구: 사회적 자본 관점)

  • Yunmo Koo;Joohyun Oh
    • Information Systems Review
    • /
    • v.21 no.3
    • /
    • pp.131-149
    • /
    • 2019
  • As smart phones, tablets, and other digital devices become more pervasive, theoretical arguments around digital divide, which has previously focused on "access," is now expanding to effectively "utilize," actively "produce" and "share" information. Such discussion is significant because the impact on inter-personal and social networks depends on how digital divides are used, which can then recreate or exacerbate social inequality structures. This study examines the effect of individual's social relations and two types of social capital (i.e., bonding and bridging) on economic and socio-participatory usage of digital devices. An empirical analysis of dataset from 740 surveys reveals that the more horizontal the social relations of the individual, the more both bonding and bridging social capital increase. However, rather than the social relationship of the individual directly influencing the two types of digital device usage, it has an indirect effect on both economic and socio-participatory usage of digital devices. In particular, mediating effects of both bonding and bridging social capital exist in the case of economic usage of digital devices, whereas bonding social capital only has mediating effects on economic usage of digital devices. We discuss the role of social capital on digital devices usage and present the theoretical and practical implications.

REPORT ON A CASE TREATED WITH LINGUAL MULTIBRACKET APPLIANCE

  • Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.26 no.6
    • /
    • pp.705-715
    • /
    • 1996
  • The lingual multibracket appliance was developed to overcome the unesthetic nature of traditional fixed orthodontic labial appliances; however, treatment with this appliance was regarded as very difficult as well as a time-consuming. Recently, these problems have been reduced because of advances in lingual bracket systems, improved indirect bonding technique and the development of more flexible wires. There has been a marked increase in the number of adults desiring orthodontic treatment over recent years and many of these patients tend to seek invisible orthodontic appliances due to esthetic reasons. Although the lingual multibracket treatment is not ideal, this form of treatment is currently the best option for the patients with esthetic concerns. Here, I would like to present a case treated successfully with lingual multibracket appliance.

  • PDF