• Title/Summary/Keyword: Indicator system

Search Result 1,402, Processing Time 0.034 seconds

Characteristics of Vibration Condition Indicator with Gear Tooth Damage (기어 손상에 따른 진동 상태표시기 특성 평가)

  • Lee, Dong-Hyung;Lee, Woong-Yong;Moon, Kyung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.611-617
    • /
    • 2015
  • In the development of a vibration-based condition monitoring system in gearbox, one of the most important research topics is a quantitative analysis and test of the effect of gear damage on vibration of gearbox. This paper presents the evaluation result of vibration condition indicator according to the gear tooth damage through the vibration test of gearbox. The dynamic load test was performed with high speed railway (KTX)'s gearbox. The vibration of gearbox was measured according to a rotational speed change with the common gear fault modes, such as pitting and tooth breakage. The characteristics and the possibility of applying of vibration condition indicator on condition monitoring system were analyzed. As a result, the value of most condition indicator is gradually increased with the severity of gear faults. The NA6 indicator shows a low variation with the rotational speed change and high sensitivity in accordance with the gear fault.

New accuracy indicator to quantify the true and false modes for eigensystem realization algorithm

  • Wang, Shuqing;Liu, Fushun
    • Structural Engineering and Mechanics
    • /
    • v.34 no.5
    • /
    • pp.625-634
    • /
    • 2010
  • The objective of this paper is to apply a new proposed accuracy indicator to quantify the true and false modes for Eigensystem Realization Algorithm using output-based responses. First, a discrete mass-spring system and a simply supported continuous beam were modelled using finite element method. Then responses are simulated under random excitation. Natural Excitation Technique using only response measurements is applied to compute the impulse responses. Eigensystem Realization Algorithm is employed to identify the modal parameters on the simulated responses. A new accuracy indicator, Normalized Occurrence Number-NON, is developed to quantitatively partition the realized modes into true and false modes so that the false portions can be disregarded. Numerical simulation demonstrates that the new accuracy indicator can determine the true system modes accurately.

The Characteristics of Foreign and Domestic Coastal Zone Management Indicator System (국내외 연안구역관리 지표체계의 특성)

  • Nam, Kwang-Woo;Oh, Ji-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.885-892
    • /
    • 2012
  • Coastal zone management indicators are being used as an important means of decision making in the process of policy establishment for integrated coastal management and implementation, and these indicators are very useful tools that enable the evaluation of the coastal zone management from an integrated perspective, the understanding and analysis of interactions according to each department. Accordingly, most of organizations in international society and advanced coastal states tend to develop coastal zone management indicator system in order to check current coastal environment, social and economic status, also to grasp effectiveness of the coastal zone management policy. In this research, therefore, the characteristics of coastal zone management indicator system was drawn through understanding of strength and weakness, and conducting comparative analysis of the coastal zone management indicator system according to each level having classified domestic and international coastal zone management indicator system into three aspects at large: natural and environmental aspect; social and economic aspect; and network aspect. As a result, following features were drawn as the common characteristics among the cases in the advanced coastal states: the management means for realization of sustainable coastal zone management; scientific decision making tools for various stakeholders; evaluation means for effectiveness of coastal zone integrated management; and dualization of coastal zone management indicator system; etc. Lastly, based on these common values revealed in the domestic and international coastal management indicator system, a suggestion for correct establishment of the domestic coastal management indicators was proposed in the regional aspect.

A Study on the Wireless Control System for the Shunting Route Indicator Applied with LTE-R technology (LTE-R 기술을 적용한 입환진로표시기 무선제어시스템 연구)

  • Suh, Ki-Bum;Im, Chul-Hoo;Lee, Kwang-Hee;Oa, Seong-Wook;Joeng, Wang-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.229-236
    • /
    • 2017
  • The railway has recently been expanded with the phase of the future transportation. Accordingly, using the new technologies such as smart devices and LTE-R, the needs for reducing operational costs and improving passenger services have emerged. To realize these needs, the government is pushing to build the dedicated wireless network for the railway systems. In this paper, the shunting route indicator was selected for this study because it has the best effect for the wireless system removed lots of wired cables. And the wireless shunting route indicator applied with LTE-R technology was developed to replace the current wired control system. The functional goal(the wireless control function applied LTE-R), the performance goal(less than 300ms for transferring the control information), and the reliability goal(over the 100,000 hours for MTBF) were set, and these goals were achieved and demonstrated through the test and validation.

DEVELOPMENT OF STATE-LEVEL APPRAISAL INDICATORS OF SUSTAINABLE CONSTRUCTION IN TAIWAN

  • Rong-Yau Huang;Wei-Ting Hsu
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.292-298
    • /
    • 2011
  • In this study we examine Taiwan's overall performance in accordance with sustainable construction by developing an appraisal indicator framework. The framework consists of five layers, from bottom to top: the indicator; the indicator category; the core cluster; the theme; and the overall performance. The procedure for the development of a sustainable construction indicator system is outlined. Finally, a framework consists of 3 themes, 10 core clusters, and 33 indicator categories are established. Following the established framework, 67 proper indicators are selected for each category in the framework, and data of the 53 indicators are collected respectively from a nation's statistical databank in Taiwan. Sustainable construction index aggregated step-by-step from the indicators, the indicator categories, the core clusters and the themes is computed to assess Taiwan's progress in sustainable construction. The preliminary results and the discussion are reported.

  • PDF

HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.114-119
    • /
    • 2017
  • In this paper we present the search on HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator. Nowadays, a growing trends in which electronic displays such as LED, LCD or plasma monitors are being installed in public places like bars, stores, entertainment areas, restaurants, lobbies, etc. In this paper, the study is curried out on efficiency of HC-06 Bluetooth module based controller driver that relates generally to the field of emergency signage management systems for displaying various indicator contents remotely on electronic displays in public and privates venues. It allows user smart devices interaction remotely with digital signage by providing content for displaying on at least one display in a venue. Depending on the emergency case, HC-06 Bluetooth based driver module proves the high efficiency as well as good performance of processing and communicating remotely the indicator based message that is displayed from a venue management control system by using smart devices. The system combines smart device that linked to HC-06 Bluetooth module with ATmega168/328 embedded micro controller which result by switching the displayer containing the digital signage indicator based message.

Indicator-free DNA Chip Array Using an Electrochemical System

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.133-136
    • /
    • 2004
  • This research aims to develop a DNA chip array without an indicator. We fabricated a microelectrode array through photolithography technology. Several DNA probes were immobilized on an electrode. Then, target DNA was hybridized and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between the DNA probe and mismatched DNA in an anodic peak. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

Analysis of Control Conflict between UPFC Multiple Control Functions and Their Interaction Indicator

  • Wang H. F.;Jazaeri M.;Cao Y. J.
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.315-321
    • /
    • 2005
  • Interactions among multiple control functions of a UPFC installed in a power system have been observed in power system simulation and been reported in authors' previous publications [1,2]. This paper presents new analytical results about these observed interactions and concludes that they are due to the control conflict between the series and shunt part of the UPFC, which are connected through the internal common capacitor inside the UPFC. Investigation in the paper reveals, for the first time as far as the authors are aware of, that the linkage pattern of UPFC series and shunt part decides whether the control functions implemented by the UPFC series and shunt part conflict each other or not. This linkage pattern of UPFC series and shunt part can be described by the flow of active power through the UPFC at steady-state operation of the power system. Hence in order to predict the possible interactions among multiple control functions of the UPFC, an interaction indicator is proposed in the paper which is the direction and amount of active power flow through the internal link of the UPFC series and shunt part at steady-state operation of the power system. This proposed interaction indicator can be calculated from power system load flow solution without having to run simulation of the power system with UPFC controllers installed. By using the indicator, the interactions among multiple control functions of the UPFC caused by badly set controller's parameters are excluded. Therefore the indicator only identifies the possible existence of inherent control conflict of the UPFC.

Development of Real-time Condition Monitoring System for Container Cranes (컨테이너 크레인 실시간 설비진단 시스템 개발)

  • Jung, D.U.;Choo, Y.Y.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.18-23
    • /
    • 2008
  • This paper describes development of real-time condition monitoring system to observe state of a container crane in a port. To analyze the state of a crane, the strength and the direction of wind are measured with sensors along with the load resulted a crane at the moment. The measured signals are processed by especially developed conditioning board and converted into digital data. Measured data are analyzed to define the state of the crane at an indicator. For transmission of these data to the indicator, we implemented wireless sensor network based on IEEE 802.15.4 MAC(Media Access Control) protocol and Bluetooth network protocol. To extend the networking distance between the indicator and sensor nodes, the shortest path routing algorithm was applied for WSN(Wireless Sensor Network) networks. The indicator sends the state information of the crane to monitoring server through IEEE 802.11 b wireless LAN(Local Area Network). Monitoring server decides whether alarm should be issued or not. The performance of developed WSN and Bluetooth network were evaluated and analyzed in terms of communication delay and throughput.

  • PDF

Development of Monthly Hydrological Cycle Assessment System Using Dynamic Water Balance Model Based on Budyko Framework (Budyko 프레임워크 기반 동적 물수지 모형을 활용한 월 단위 물순환 평가체계 개발)

  • Kim, Kyeung;Hwang, Soonho;Jun, Sang-Min;Lee, Hyunji;Kim, Sinae;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.2
    • /
    • pp.71-83
    • /
    • 2022
  • In this study, an indicator and assessment system for evaluating the monthly hydrological cycle was prepared using simple factors such as the landuse status of the watershed and topographic characteristics to the dynamic water balance model (DWBM) based on the Budyko framework. The parameters a1 of DWBM are introduced as hydrologic cycle indicators. An indicator estimation regression model was developed using watershed characteristics data for the introduced indicator, and an assessment system was prepared through K-means cluster analysis. The hydrological cycle assessment system developed in this study can assess the hydrological cycle with simple data such as land use, CN, and watershed slope, so it can quickly assess changes in hydrological cycle factors in the past and present. Because of this advantage is expected that the developed assessment system can predict changes in the hydrological cycle and use an auxiliary tool for policymaking.