• 제목/요약/키워드: Index n

검색결과 3,516건 처리시간 0.033초

Memory Organization for a Fuzzy Controller.

  • Jee, K.D.S.;Poluzzi, R.;Russo, B.
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1041-1043
    • /
    • 1993
  • Fuzzy logic based Control Theory has gained much interest in the industrial world, thanks to its ability to formalize and solve in a very natural way many problems that are very difficult to quantify at an analytical level. This paper shows a solution for treating membership function inside hardware circuits. The proposed hardware structure optimizes the memoried size by using particular form of the vectorial representation. The process of memorizing fuzzy sets, i.e. their membership function, has always been one of the more problematic issues for the hardware implementation, due to the quite large memory space that is needed. To simplify such an implementation, it is commonly [1,2,8,9,10,11] used to limit the membership functions either to those having triangular or trapezoidal shape, or pre-definite shape. These kinds of functions are able to cover a large spectrum of applications with a limited usage of memory, since they can be memorized by specifying very few parameters ( ight, base, critical points, etc.). This however results in a loss of computational power due to computation on the medium points. A solution to this problem is obtained by discretizing the universe of discourse U, i.e. by fixing a finite number of points and memorizing the value of the membership functions on such points [3,10,14,15]. Such a solution provides a satisfying computational speed, a very high precision of definitions and gives the users the opportunity to choose membership functions of any shape. However, a significant memory waste can as well be registered. It is indeed possible that for each of the given fuzzy sets many elements of the universe of discourse have a membership value equal to zero. It has also been noticed that almost in all cases common points among fuzzy sets, i.e. points with non null membership values are very few. More specifically, in many applications, for each element u of U, there exists at most three fuzzy sets for which the membership value is ot null [3,5,6,7,12,13]. Our proposal is based on such hypotheses. Moreover, we use a technique that even though it does not restrict the shapes of membership functions, it reduces strongly the computational time for the membership values and optimizes the function memorization. In figure 1 it is represented a term set whose characteristics are common for fuzzy controllers and to which we will refer in the following. The above term set has a universe of discourse with 128 elements (so to have a good resolution), 8 fuzzy sets that describe the term set, 32 levels of discretization for the membership values. Clearly, the number of bits necessary for the given specifications are 5 for 32 truth levels, 3 for 8 membership functions and 7 for 128 levels of resolution. The memory depth is given by the dimension of the universe of the discourse (128 in our case) and it will be represented by the memory rows. The length of a world of memory is defined by: Length = nem (dm(m)+dm(fm) Where: fm is the maximum number of non null values in every element of the universe of the discourse, dm(m) is the dimension of the values of the membership function m, dm(fm) is the dimension of the word to represent the index of the highest membership function. In our case then Length=24. The memory dimension is therefore 128*24 bits. If we had chosen to memorize all values of the membership functions we would have needed to memorize on each memory row the membership value of each element. Fuzzy sets word dimension is 8*5 bits. Therefore, the dimension of the memory would have been 128*40 bits. Coherently with our hypothesis, in fig. 1 each element of universe of the discourse has a non null membership value on at most three fuzzy sets. Focusing on the elements 32,64,96 of the universe of discourse, they will be memorized as follows: The computation of the rule weights is done by comparing those bits that represent the index of the membership function, with the word of the program memor . The output bus of the Program Memory (μCOD), is given as input a comparator (Combinatory Net). If the index is equal to the bus value then one of the non null weight derives from the rule and it is produced as output, otherwise the output is zero (fig. 2). It is clear, that the memory dimension of the antecedent is in this way reduced since only non null values are memorized. Moreover, the time performance of the system is equivalent to the performance of a system using vectorial memorization of all weights. The dimensioning of the word is influenced by some parameters of the input variable. The most important parameter is the maximum number membership functions (nfm) having a non null value in each element of the universe of discourse. From our study in the field of fuzzy system, we see that typically nfm 3 and there are at most 16 membership function. At any rate, such a value can be increased up to the physical dimensional limit of the antecedent memory. A less important role n the optimization process of the word dimension is played by the number of membership functions defined for each linguistic term. The table below shows the request word dimension as a function of such parameters and compares our proposed method with the method of vectorial memorization[10]. Summing up, the characteristics of our method are: Users are not restricted to membership functions with specific shapes. The number of the fuzzy sets and the resolution of the vertical axis have a very small influence in increasing memory space. Weight computations are done by combinatorial network and therefore the time performance of the system is equivalent to the one of the vectorial method. The number of non null membership values on any element of the universe of discourse is limited. Such a constraint is usually non very restrictive since many controllers obtain a good precision with only three non null weights. The method here briefly described has been adopted by our group in the design of an optimized version of the coprocessor described in [10].

  • PDF

폭염 시 어린이공원의 온열환경 (Thermal Environments of Children's Parks during Heat Wave Period)

  • 류남형;이춘석
    • 한국조경학회지
    • /
    • 제44권6호
    • /
    • pp.84-97
    • /
    • 2016
  • 본 연구는 폭염 시 어린이공원 내 포장 및 차양의 유형에 따른 온열환경을 규명하고자 하였다. 이를 위해 진주기상대에서 측정한 일 최고기온이 $35.9{\sim}36.8^{\circ}C$를 나타낸 2016년 8월 11일부터 8월 13일까지 3일간 진주시내 어린이공원 2곳(칠암어린이공원: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}531.7{^{\prime}^{\prime}}$, 표고: 38m; 가호제12어린이공원: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, 표고: 24m)의 모래밭, 고무칩포장지, 쉘터, 녹음지를 대상으로 미기상을 측정하였다. 미기상환경으로서 지상 60cm 높이에서 기온, 흑구온도, 상대습도, 풍속, 6방향의 장파 및 단파 복사를 측정하였고, 이를 바탕으로 열스트레스 지수인 WBGT와 UTCI를 산정 및 분석하였다. 또한 열화상카메라로 포장면과 놀이시설의 표면온도를 측정하였으며, 이를 바탕으로 단시간 피부접촉시 화상의 위험을 평가하였다. 연구결과는 다음과 같다. 어린이공원의 3일 시간 평균 최고 기온은 $36.6{\sim}39.4^{\circ}C$였으며, 모래밭에 비해 녹음에서 $2.8^{\circ}C$, 쉘터에서 $1.0^{\circ}C$$2.3^{\circ}C$ 낮게 나타났다. 시간 평균 최저 습도는 44~50%였으며, 모래밭이나 고무칩포장지에 비해 녹음에서 6%, 쉘터에서 4% 및 6% 높게 나타났다. 열사병위험지수 WBGT 값에 근거하면 폭염 시 어린이공원의 주간의 열사병 위험도는 높은 또는 극심한 정도로 나타났다. 3일 30분 평균 최고 WBGT 값은 $31.2{\sim}33.6^{\circ}C$였으며, 모래밭에 비해 녹음에서 $2.8^{\circ}C$, 쉘터에서 $2.3^{\circ}C$$1.0^{\circ}C$ 낮게 나타났으나, 차양에 의해서도 열사병 위험을 피할 수는 없었다. 체감더위지수 UTCI 값에 근거하면 폭염 시 어린이공원의 주간의 온열 스트레스의 범주는 매우 강한 또는 극심한 정도로 나타났다. 3일 30분 평균 최고 UTCI 값은 $39.9{\sim}48.1^{\circ}C$였으며, 모래밭에 비해 녹음에서 $7.8^{\circ}C$, 쉘터에서 $8.2^{\circ}C$$4.1^{\circ}C$ 낮게 나타났으나, 차양에 의해서도 극심한 또는 매우 강한 온열 스트레스를 강한 또는 적정한 온열 스트레스로 낮출 수는 없었다. 단시간 피부접촉에 의한 화상 온도 기준에 따르면, 놀이시설 및 포장면의 최고 표면온도가 스텐레스 스틸($70.8^{\circ}C$)은 무도장 철재 3초 $60^{\circ}C$, 고무칩포장($76.5^{\circ}C$)은 플라스틱 5초 $74^{\circ}C$, 청색 플라스틱 미끄럼판($68.5^{\circ}C$)과 앉음판($71.0^{\circ}C$)은 플라스틱 1분 $60^{\circ}C$ 기준을 초과한 것으로 나타났다. 하지만 그늘이 진 놀이시설의 표면온도는 햇빛에 노출된 놀이시설의 표면온도에 비해 $20^{\circ}C$ 내외로 낮게 나타나, 차양에 의해 화상의 위험을 현저하게 개선할 수 있을 것으로 판단된다. 폭염 시에는 어린이공원의 온열환경은 어린이들에게 높거나 극심한 열사병 위험에 빠지게 하고, 매우 강한 또는 극심한 온열 스트레스를 주기 때문에 보호자나 관리자가 어린이들의 어린이공원 이용을 제한해야 한다. 그리고 폭염시에는 어린이공원의 포장면 또는 놀이시설에 의한 화상의 위험이 매우 높으므로 이용 시 주의를 해야 하며, 화상의 예방을 위해서는 차양시설을 적극적으로 도입해야 한다.

운주사 석조문화재의 보존상태와 보존방안에 대한 연구 (A Study on the Conservation State and Plans for Stone Cultural Properties in the Unjusa Temple, Korea)

  • 김사덕;이찬희;최석원;신은정
    • 헤리티지:역사와 과학
    • /
    • 제37권
    • /
    • pp.285-307
    • /
    • 2004
  • 이 연구에서는 전남 화순군에 위치한 운주사의 석조문화재를 중심으로 암석의 풍화대 형성과 풍화의 진행에 따른 암석학적 특성과 지화학적 특성을 종합 검토하였다. 이 결과를 중심으로 석조물을 이루는 암석의 기계적, 화학적, 광물학적 및 물리적 풍화에 영향을 미치는 풍화요소를 규명하였고, 이들을 정량화하여 석조문화재의 보존방안 강구를 위한 기초자료로 활용하고자 한다. 이 연구를 위하여 야외 정밀조사 및 총 18개의 시료(화산력 응회암 7점, 화산회 응회암 4점, 화강암류 4점, 화강편마암 3점)에 대한 전암분석과 암석의 특성 및 광물감정을 실시하였다. 또한 각각의 석조물에 대한 훼손현황을 반정량적으로 기재하였다. 운주사 일대의 지질을 이루는 암석은 화산력 응회암이며 대체로 N30-40W의 주향과 10~20NE의 경사를 갖고 있다. 이 화산력 응회암은 운주사를 중심으로 매우 넓게 분포하고 있으며 운주사 경내에 분포하는 석조물은 모두 화산력 응회암으로 조형되어 있다. 현재 운주 사 경내의 석조물들은 대부분 심한 균열의 발달과 함께 구조적 불균형을 이루고 있으며, 생물학적 오염 및 암석의 풍화가 상당히 진행되어 각력이 탈락하고 광물의 입상분해가 발생하는 등 풍화와 훼손양상이 아주 심각하다. 또한 석조물 곳곳의 철편과 시멘트 몰탈은 산화되어 적갈색의 침전물과 회백색의 침전물을 형성하고 있다. 이들 석조물에 대해 육안 훼손정도를 기재한 결과 대부분의 석조물들이 MD(moderate damage)에서 SD(severe damage) 등급의 훼손정도를 보이고 있다. 각 암석의 X선 회절분석 결과, 대부분의 시료들은 석영, 정장석, 사장석, 방해석 및 자철석 등의 광물로 구성되어 있다. 현미경하에서는 석영과 장석류가 심하게 변질되었으며, 타형의 결정형을 보이는 흑운모는 풍화되어 이차 풍화광물인 녹니석으로 변질되어 있다. 또한 응회암 곳곳의 열극대에 적갈색의 철분 침전물이 관찰되는 것으로 보아 암석의 내부까지 풍화가 진행되고 있음을 알 수 있다. 연구지역의 석조물을 이루는 응회암류는 Subalkaline, Peraluminous의 영역에 도시되며, 시료의 $SiO_2$(wt.%) 범위는 화산력 응회암이 70.08~73.69, 화산회 응회암은 70.26~78.42 의 범위를 보이고 있다. 또한 주성분원소에 대한 화학적풍화지수(CIA)와 풍화잠재지수(WPI) 계산치에서 CIA의 범위는 화산력 응회암은 55.05~60.75, 화산회 응회암은 52.10~58.70, 화강암은 49.49~51.06 화강편마암은 53.25~67.14의 범위를 보이며 이들은 편마암류와 응회암류에서 큰 값을 갖는다. WPI는 응회암류와 편마암류의 시료에서 0선 이하에 있거나 0선에 근접되어 도시되는 것으로 보아 상위 CIA에서와 같이, 이들 응회암류와 편마암류가 화학적인 풍화 작용을 쉽게 받고 있음을 시사한다. 암석의 분말시료와 석조물의 피복시료를 채취하여 전자현미경(SEM)으로 관찰한 결과 암석의 이차적인 풍화산물인 스멕타이트, 불석군의 점토광물이 관찰된다. 그리고 암석의 생물학적 풍화 요소인 하등식물의 균사류 및 지의류의 모근과 포자가 함께 관찰된다. 이는 암석의 내부까지 생물체가 압력을 가하고 있어 석조물의 기계적 풍화작용을 가중시키고 있으며, 이와 함께 석조물 내에 점토광물화가 상당히 진행된 것으로 판단된다. 암석의 풍화가 상당히 진행되어 비, 바람, 수목, 지반 등 자연환경 의해 훼손이 가속화 되고 있는 상태이다. 이에 대한 방안으로 1차 수목 제거 등 주변 환경정비와 배수로 설치 등 물 침투 방지에 대한 지반환경 조성이 필요하고, 2차 지의류 제거 등 생물학적 처리와 합성수지를 사용한 균열부분 접착복원과 암석 재질을 강하게 하는 경화 및 발수처리를 실시한다. 그리고 풍화의 원인인 바람, 햇빛, 비 등을 차단시킬 수 있고 주변경관과 어울리는 보호시설을 건립하여 보존하는 것이 좋을 것으로 판단된다.

중부 지역 여대생에서 음식섭취빈도조사지를 이용한 나트륨 섭취량 평가 및 나트륨 섭취와 골밀도와의 관련성 조사 (Evaluation of Sodium Intake and Relationship between Sodium Intake and the Bone Mineral Density of Female University Students)

  • 배윤정;연지영
    • 동아시아식생활학회지
    • /
    • 제21권5호
    • /
    • pp.625-636
    • /
    • 2011
  • 본 연구는 여대생 248명을 대상으로 음식섭취빈도조사지에 의한 나트륨 섭취량과 골밀도와의 관련성을 규명하고자 하였다. 조사 대상자의 평균 연령은 정상군 20.15세, 골감소군 20.04세였으며, 두 군간 유의적인 차이는 보이지 않았다. 평균 신장과 체중은 정상군 161.14 cm, 54.99 kg, 골감소군은 161.02 cm, 52.20 kg으로 나타나, 골감소군에서 체중이 유의적으로 낮은 것으로 나타났다. 평균 체질량지수와 체지방량은 정상군 20.90 kg/$m^2$, 26.09%, 골감소군은 20.08 kg/$m^2$, 24.27%으로 체질량지수와 체지방이 골감소군에서 유의적으로 낮은 것으로 나타났다. 평균 종골의 골격 상태 측정 결과에서 BUA, SOS, QUI는 정상군 118.44 dB/MHz, SOS 1,578.12 m/s, QUI 124.59%, 골감소군은 99.24 dB/MHz, SOS 1534.50 m/s, QUI 98.83%로 골감소군이 유의적으로 낮은 것으로 나타났다. 음식섭취빈도지에 의한 나트륨 섭취량(3,176.51 mg)은 식사 기록법에 의한 나트륨 섭취량(1,898.62 mg)과 유의한 양의 상관관계를 보였으며, 정상군 3,598.60 mg, 골감소군 3,748.25 mg으로 두 군간 유의적인 차이를 보이지 않았다. 나트륨 섭취의 주요 급원식품으로 정상군은 배추김치(10.13%), 라면(5.05%), 된장찌개(3.27%), 김치찌개(3.23%), 멸치볶음(2.48%) 순으로나타났으며, 골감소군은 배추김치(12.78%), 라면(6.04%), 김치찌개(2.94%), 된장찌개(2.62%), 자반고등어(2.34%) 순으로 나트륨 섭취량이 많게 나타났다. 음식군별 나트륨 섭취에 기여하는 음식군별 결과를 살펴보면, 정상군은 김치류(16.91%), 면류 및 만두류(16.34%), 찌개 및 탕류(13.88%), 주반찬(육류, 난류, 콩류, 11.73%), 어패류(11.02%) 순으로 나타났으며, 골감소군은 김치류(20.51%), 면류 및 만두류(17.03%), 찌개 및 탕류(12.98%), 어패류(10.76%), 주반찬(육류, 난류, 콩류, 10.63%) 순으로 나타났다. 두 군 모두에서 김치류, 면류 및 만두류, 찌개 및 탕류, 주반찬(육류, 난류, 콩류), 어패류로부터 전체 나트륨 섭취의 70% 정도를 공급받고 있는 것으로 나타났다. 조사대상자의 각 식품군의 나트륨 섭취량과 골밀도와의 상관 관계 분석결과, 면류 및 만두류(r=-0.0276, p=0.0426)와 나물 및 생채류(r=-0.0587, p=0.0015)와 골밀도간의 유의적인 음의 상관관계를 나타내었다. 각 식품군의 섭취빈도와 골밀도와의 상관관계 결과, 면류 및 만두류(r=-0.0344, p=0.0116), 찌개 및 탕류(r=-0.0376, p=0.0008), 김치류(r=-0.0421, p=0.0482), 어패류(r=-0.0160, p=0.0362), 나물 및 생채류(r=-0.0503, p= 0.0064), 양념류(r=-0.0407, p=0.0347) 등과 유의적인 음의 상관관계를 보였다. 나트륨 섭취 상태와 골밀도와의 관련성을 알아보기 위하여 나트륨 섭취량에 따라 4분 위수로 대상자를 나누어 비교한 결과, 정상군의 T-score는 Q1 군 0.90 g/$cm^2$, Q2군 1.03 g/$cm^2$, Q3군 0.91 g/$cm^2$, Q4군 0.98 g/$cm^2$으로 군간 유의적인 차이를 보이지 않았고, 골감소군은 Q1군 -1.48 g/$cm^2$, Q2군 -1.61 g/$cm^2$, Q3군 -1.59 g/$cm^2$, Q4군 -1.71 g/$cm^2$으로 군간 유의적인 차이를 보이지 않았다. 이상의 연구 결과에서 여대생의 주요 나트륨 급원 식품인 배추김치, 김치찌개, 된장찌개 이외의 라면, 멸치볶음, 스낵 과자의 식품으로부터 나트륨 섭취가 높은 것으로 나타났다. 또한 나트륨 총 섭취량과 골밀도는 상관성이 없었고 나트륨 섭취 기여도가 높은 식품의 섭취빈도가 높은 경우 나트륨 섭취도 높았는데, 이는 골밀도에 따른 군간 나트륨 섭취가 유사하여 나트륨 섭취가 골밀도에 미치는 효과가 미약하게 나타나 것으로 보인다. 따라서 골밀도에 관련성이 있는 골대사 지표 및 다양한 측정 방법을 통한 골밀도와 나트륨 섭취수준과의 관련성 연구가 필요하다고 생각된다.

조기유방암에서 유방보존수술 및 방사선치료후의 미용적 결과 (Cosmetic Results of Conservative Treatment for Early Breast Cancer)

  • 김보경;신성수;김성덕;하성환;노동영
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.21-26
    • /
    • 2001
  • 목적 : 보존적수술 후 방사선치료를 받은 유방암 환자를 대상으로 한국인에서의 조기 유방암의 보존적치료의 전반적인 미용적 결과와 유방의 대칭성 및 이에 영향을 미치는 인자들을 분석을 위하여 본 연구를 시행하였다. 대상 및 방법 : 1992년 2월부터 1997년 1월까지 조기유방암으로 보존적수술 후 서울대학교병원 치료방사선과에서 방사선치료를 시행 받은 120명의 환자를 대상으로 하였다. 대상 환자들의 추적관찰 기간은 16개월에서 74개월로 중앙값은 33개월이었다. 유방보존수술은 사분위절제술 및 액와림프절절제술 108례, 종양절제술 및 액와림프절절제술 4례, 종양절제술 2례, 전절제 생검술 4례, 피하유방절제술 및 액와림프절 절제술이 2례였다. 수술 후 방사선치료는 4 MV, 6 MV 또는 10 MV X 선을 이용하여 1 일 1.8 Gy 씩 50.4 Gy를 유방전체에 접선조사야로 조사한 후 원발부위에 7 또는 9 MeV 전자선으로 1일 2 Gy 씩 10 Gy를 추가조사하였으며 21례에서 액와림프절과 쇄골상 림프절을, 9례에서 액와림프절, 쇄골상림프절, 내유림프절을 치료범위에 포함하였다. 항암화학요법은 총 46례에서 시행하였으며, 45례에서 CMF (cyclophosphamide, methotrexate, 5-fluorouracil) 복합요법 6회를, 1례에서 CAF (cyclophosphamide, doxorublcin, 5-fluorouracil) 복합요법 12회를 시행하였다. 전반적인 미용적 결과는 유방의 부종(edema), 수축(retraction), 상승(elevation), 섬유화(fibrosis), 경화(induration) 및 피부변화 등을 고려하여 excellent, good, fair, poor 의 4 단계로 평가하였으며, 유방의 대칭성의 판정을 위하여 symmetry index를 사용하였다 전반적인 미용적 결과의 비교 및 분석을 위하여 polytomous logistic regression 방법을 사용하였고, 유방의 대칭성 평가를 위해 logistic regression 방법을 사용하였다. 결과 : 최종 추적관찰 시 전반적인 미용적 결과는 excellent가 29명$(24\%)$, good 62명$(52\%)$, fair 23명$(19\%)$, poor가 6명$(5\%)$으로 $76\%$의 환자에서 good 이상의 결과를 보였다. 단변량분석 상 종양의 크기가 2 cm 이하인 경우 (p=0.04), 림프절 전이가 없는 경우(p:0.0002), 종양 절제술 또는 전절제생검술을 시행한 경우 (p=0.02), 방사선치료의 범위에 액와림프절이 포함되지 않은 경우(p=0.0005), 항암화학요법을 시행하지 않은 경우(p=0.0001) 더 좋은 미용적 결과를 보였다. 다변량분석 상 종양절제술 또는 전절제생검만을 시행한 경우(p=0.04), 항암화학요법을 시행하지 않은 경우(p=0.0002)에 더 좋은 미용적 결과를 보였다. 유방의 대칭성에 영향을 미치는 요인으로는 단변량분석 상 종양의 크기가 2 cm 이하인 경우(p=0.0007), 림프절 전이가 없는 경우(p=0.005), 항암화학요법을 시행하지 않은 경우 (p=0.001), 방사선치료의 범위에 액와림프절이 포함되지 않은 경우(p=0.02) 에 더 좋은 유방의 대칭성을 보였으며 종양절제술 또는 전절제생검만을 시행한 경우(p=0.09) 대칭성이 높은 경향을 보였다. 다변량분석 상으로는 종양의 크기가 2 cm 이하인 경우(p=0.003), 림프절 전이가 없는 경우(p=0.007) 더 좋은 유방의 대칭성을 보였다. 결론 : 조기유방암에서의 보존적수술 및 방사선치료는 $76\%$의 환자에서 good 이상의 미용적 결과를 보였다. 또한 대상 환자 중 종양의 크기가 작은 경우, 액와림프절 전이가 없는 경우 및 수술의 범위가 작은 경우 미용적 결과가 더 우수함을 확인할 수 있었다.

  • PDF

일부 남녀 중학생의 건강 관련 임상증상에 따른 식습관과 체헝관심도에 관한 연구 (A Comparative Study of Food Habits and Body Satisfaction of Middle School Students According to Clinical Symptoms)

  • 승정자
    • 한국식품영양과학회지
    • /
    • 제34권2호
    • /
    • pp.202-208
    • /
    • 2005
  • 본 연구에서는 청소년기 남녀 중학생의 건강과 관련된 임상 증상에 따른 식습관, 영양지식, 영양태도를 알아보기 위하여 조사를 실시하였다. 좋지 않은 건강상태를 나타내는 임상증상 중 자주 생긴다고 답한 항목이 1개 이하인 경우를 건강군, 2개 이상의 항목에서 자주 생긴다고 답한 경우를 비건강군으로 분류하여 각 조사 항목을 비교 분석한 결과를 요약하면 다음과 같다. 전체 대상자들(524명)의 평균 연령은 14.0세였으며, 신장은 남학생 162.0 cm, 여학생 157.2 cm였고, 체중은 남학생 53.4 kg, 여 학생 49.4 kg으로 신장과 체중 모두 남학생이 높았다. 신장과 체중으로부터 산출한 체질량지수(BMI)는 남학생 20.3 kg/$m^2$, 여학생 20.0 kg/$m^2$로 모두 정상 범위에 속하였다. 건강군(289명)과 비건강군(235명)의 평균 연령, 체중, 신장, 체질량지수는 유의적인 차이를 보이지 않았다. 체형 인식, 만족도, 체중조절 시도여부를 비교한 결과 본인의 체형에 대한 인식은 건강군과 비건강군 간에서 유의적인 차이를 보이지 않았으나, 체형만족도에서는 유의적인 차이를 보여 본인의 체형에 만족하지 않는다는 비율이 건강군 여자의 33.1%에 비하여 비건강군 여자는 46.2%로 높게 나타났다(p<0.05). 지난 1년간의 체중조절 시도 여부에 대하여서도 비건강군 여자의 59.5%가 체중을 감소시키기 위하여 노력하였다고 답하여 건강군 여자의 38.5%에 비하여 유의적으로 높았다(p<0.01). 남학생의 경우에는 체형만족도와 체중 조절 경험에 있어서 두 군간 유의한 차이를 보이지 않았다. 영양지식과 영양태도 점수를 비교한 결과 건강군과 비건강군간에 유의적인 차이를 보이지 않았다. 끼니별 식사빈도를 조사한 결과 여자의 경우 아침식사를 주4회 이하로 하는 경우가 건강군은 30.7%였으나, 비건강군의 경우 44.0%로 높았다(p<0.05). 저녁 식사는 주 4회 이하의 식사를 하는 경우가 건강군은 10.7%인 반면, 비건강군은 18.8%로 아침 과 저녁 식사 모두 여자 비건강군의 결식률이 유의적으로 높게 나타났다(p<0.01).외식빈도는 남자의 경우 주 3회 이상에서 비건강군이 56.5%로 건강군의 42.7%보다 유의적으로 높았으며, 간식빈도는 여자의 경우 건강군에 비하여 비건강군이 유의적으로 높았다(p<0.05).식사의 구성을 조사한 결과 유의적인 차이를 보이지는 않았으나 비건강군이 건강군에 비하여 세 끼 식사의 구성이 불량하다고 답한 비율이 높은 경향을 나타내었다. 본 연구 결과를 통하여 건강의 이상 여부를 반영하는 임상증상의 빈도가 높은 청소년기 남녀 중학생의 경우 아침과 저녁의 결식빈도 및 외식과 간식의 빈도가 높았고, 아침식사의 질과 체형만족도가 낮은 것으로 나타나 청소년의 건강과 식습관 및 체형만족도가 상호 관련성이 높은 것으로 나타났다. 따라서 본 연구 결과는 성장기 청소년의 건강 유지를 위하여 바람직한 식습관의 중요성을 재인식할 수 있었으며, 올바른 식습관 확립을 위한 영양교육의 중요성이 재확인되었다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

청소년의 인터넷 중독 : 수면, 우울과의 관련성 (Internet Addiction in Adolescents and its Relation to Sleep and Depression)

  • 송호광;정미향;성다정;정정경;최진숙;장용이;이진성
    • 수면정신생리
    • /
    • 제17권2호
    • /
    • pp.100-108
    • /
    • 2010
  • 목 적: 컴퓨터의 보급으로 인터넷 사용이 보편화되면서 인터넷 중독에 대한 관심이 증가하고 있다. 그러나 인터넷 중독의 정확한 병태생리에 대한 이해와 진단 기준은 아직 확립되어 있지 않다. 청소년은 발달 과정 중에 있기 때문에 인터넷 중독에 더 취약할 가능성이 있으며, 우울감과 수면 문제에 대한 이해가 중요하다. 본 연구에서는 청소년의 인터넷 중독, 수면 양상, 그리고 우울감의 특징과 그 연관성을 살펴보고자 하였다. 방 법:서울 시내 일 중, 고등학교의 중학교 2학년(155명), 고등학교 1, 2학년 학생(644명)을 대상으로 하였고 그 중 696명의 설문지를 분석 대상으로 하였다. 설문지에는 Young 인터넷 중독 척도(Young's Internet Addiction Scale, YI-AS), 피츠버그 수면의 질 척도(Pittsburgh Sleep Quality In-dex, PSQI), 우울감 척도(The Center for Epidemiologic Studies Depression Scale, CES-D), 그리고 인터넷 사용 패턴과 기본적인 인구학적 정보에 대한 질문들이 포함되었다. 연구 대상자들을 학년별, YIAS 점수에 따라 나누어 비교하였고, YIAS와 다른 변인과의 상관관계를 분석하였다(two-tailed, p<0.05). 결 과: 인터넷 중독군(internet-addicted, IA)은 14명(2.0%), 과사용군(over-using, ou)은 193명(27.7%), 비중독군(not-addicted, NA)군은 489명(70.3%) 이었으며, 전체 대상군의 평균 IAS 점수는 35.24점, PSQI 점수는 5.53점, CES-D 점수는 16.72점이었다. 평일 평균적인 수면 시간은 학년이 올라가면서 점점 감소하였다(F=51.909, p< 0.001). IA군, OU군, NA군으로 나누어 비교하였을 때 컴퓨터를 공부 이외의 목적으로 사용하는 시간(96.36${\pm}$63.31분 vs. 134.92${\pm}$86.79분 vs. 213.57${\pm}$136.87분, F=34.287, p<0.001), 휴대용 전자기기를 공부 이외의 목적으로 사용하는 시간(84.22${\pm}$79.11분 vs. 96.97${\pm}$91.89분 vs. 152.31${\pm}$93.64분, F=5.400, p=0.005)에 유의한 차이가 있었다. PSQI 총점(5.26${\pm}$2.97 vs. 6.08${\pm}$2.97 vs. 7.50${\pm}$4.41, F= 8.218, p<0.001)과 CES-D 점수(15.40${\pm}$8.08 vs. 19.05${\pm}$8.42 vs. 30.43${\pm}$13.69, F=32.692, p<0.001)에서도 유의한 차이가 있었다. YIAS 점수는 컴퓨터를 공부 이외의 목적으로 사용하는 시간(r=0.356, p${\pm}$0.001), 휴대용 전자기기를 공부 이외의 목적으로 사용하는 시간(r=0.136, p<0.001)과 유의한 상관관계가 있었다. YIAS 점수와 PSQI 점수(r= 0.131, p=0.001), YIAS 점수와 CES-D 점수(r=0.265, p< 0.001), PSQI 점수와 CES-D 점수(r=0.357, p<0.001)는 서로 유의한 상관관계가 있었다. 결 론: 인터넷 중독은 행위 중독의 한 가지로 여러 정신병리와 관련이 있을 뿐만 아니라, 수면의 질을 결정하는 여러 가지 요인들, 우울감과도 밀접한 관련이 있다는 것을 알 수 있었다. 따라서 청소년의 인터넷 중독을 평가할 때 동반될 우울감과 수면 양상에 대한 고려가 함께 이루어지는 통합적인 접근이 필요할 것이다.

  • PDF

열적, 기계적 피로응력이 교정용 브라켓의 결합강도에 미치는 영향 (Effects of Thermal and Mechanical Fatigue Stress on Bond Strength in Bracket Base Configurations)

  • 김정기;김상철
    • 대한치과교정학회지
    • /
    • 제30권5호
    • /
    • pp.625-642
    • /
    • 2000
  • 본 연구는 열적 및 기계적 피로응력이 교정용 브라켓의 전단결합강도, 인장결합강도, 전단-인장 복합 결합강도에 미치는 영향과 결합상태에 미치는 영향, 그리고 접착파절 양상을 비교하는데 목적이 있다. 이를 위하여 기저부 형태가 다른 5종의 금속 브라켓을 교정치료를 목적으로 발거한 상$\cdot$하악 소구치에 부착하여, 계면에 200g의 전단-인장 복합 하중을 4주간 가한 기계적 피로시험과, 5,000회의 thermocycling을 시행한 열적 피로시험 후, 전단결합강도, 인장결합강도, 및 전단-인장 복합 결합강도를 측정하고, 파절양상을 분석하여 다음과 같은 결과를 얻었다. 1. 정적시험에서 얻은 브라켓 접착부의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았다(p<0.05). 모든 종류의 브라켓에서 전단결합강도가 가장 컸으며, 전단-인장 복합 결합강도는 전단결합강도의 1/3 수준으로 가장 작았다. 2. 4주간 200g의 전단-인장 복합 하중을 가한 후의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았으며 (p<0.05), 기계적 피로시험 후 Photoetched base와 Micro-Etched Foil Mesh base의 전단, 인장, 전단-인장 복합 결합강도가 감소하였고, Chessboard base의 전단결합강도가 감소하였다(p<0.05). 3. 5,000회의 thermocycling 후의 결합강도는 Photoetched base가 가장 컸고, integral base가 가장 작았으며(p<0.05), 열적 피로시험 후 Photoetched base와 Chessboard base, Micro-Etched Foil Mesh base의 결합강도가 모두 감소하였다(p<0.05). 4. 정적시험의 결합강도 측정 후 접착파절은 브라켓/레진 계면에서 일어났으며, thermocycling 후에는 브라켓/레진 계면과, 법랑질/레진 계면, 레진내 파절이 혼합되어 나타나 ARI 점수가 높아졌다. 기계적 피로시험 후에는 정적시험 때와 비슷한 ARI 점수를 보였다. 5. 모든 브라켓에서 thermocycling 후 브라켓/레진 계면과 법랑질/레진 계면에서 미세 균열이 관찰되었다.

  • PDF