• Title/Summary/Keyword: Index ion

Search Result 197, Processing Time 0.03 seconds

A Co- mparision of Normocholesterolemia and Hypercholesterolemia in Middle-Aged Men in Kwang-ju (광주지역 중년남성의 정상콜레스테롤혈증군과 고콜레스테롤혈증군의 비교)

  • 허영란;임현숙
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.3
    • /
    • pp.327-337
    • /
    • 1997
  • The purpose of this study was to investigate the differences in anthropometric, hematologic, and lipidologic data between normocholesterolemia and hypercholesterolemia and influencing factors in hypercholesterolemia in middle-aged men in Kwang-ju. 179 middle-aged men were involved. Anthropometric data(body weight, height, body circumferences and skinfold thickness) and hematologic data(blood pressure, fasting blood glucose, albumin and hemoglobin) were measured. Bleed lipid profile(total cholesterol, tr- iglyceride, phospholipid, HDI-cholesterol, LDL-cholesterol and VLDL-cholesterol) were analyzed. To determined using questionnaire. The subjects were classified as hypercholesterolemic based on The Guideline for Korean Hyperlipidemia. body mass index, systolic blood pressure, waist and hip circumference, and triceps, subcostal, abdomen, subscapular and suprailliac skinfold thicknesses of the hypercholesterolemic group were significantly higher than in the normocholesterolemic group. The concentrat- ion of cholesterol, triglyceride, phospholipod. HDL-cholesterol, LDL-cholesterol and VLDL -cholesterol of the hypercholesterolemic group were significantly higher than normocholesterolemic group. The concentration of cholesterol has a significantly positive correlation with body mass index, diastolic blood pressure, waist circumference, waist/thigh ratio and skinfold thickness(triceps, subcostal, abdomen, and supraillic skin- fold thickness). The general tendency of socioeconomec status, frequencyu of meat intake, smoking amounts and duration and duration and drinking frequencies and amount were higher in the hypercholesteolemic group but not significant. In conclusion, hypercholesterolemia in middle-aged men was closely correlated with upper body fat obesity and most of them had an accompanied high triglyceride level tendency.

  • PDF

The Effect of Substrate Bias Voltage during the Formation of BN film by R. F. Sputtering Method (RF 스퍼터링법에 의한 BN박막 증착시 기판 바이어스전압의 영향에 관한 연구)

  • 이은국;김도훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 1996
  • In this work BN thin films were deposited on Si substrate by R. F. sputtering method at $200^{\circ}C$ and in Ar + $N_2$ mixed gas atmosphere. In order to investigate the effect of ion bombardment on substrate for c-BN bonding, substrate bias voltage was applied. The optimum substrate bias voltage for c-BN bonding was determined by FTIR analysis on specimens which were deposited with various bias voltages. Then BN thin film was deposited with this optimum condition and its phase, morphology, chemical composition, and refractive index were compared with those of BN film which was deposited without bias voltage. FTIR results showed that BN films deposited with substrate bias voltage were composed of mixed phases of c-BN and h-BN, while those deposited without bias voltage were h-BN only. When pure Ar gas was used for sputtering gas, BN films were delaminated easily from substrate in air, while when 10% $N_2$ gas was added to the sputtering gas, although c-BN specific infrared peak was reduced, delamination did not occur. GXRD and TEM results showed that BN films were amorphous phases regardless of substrate bias voltage, and AES results showed that the chemical compositions of B/N were about 1.7~1.8. The refractive index of BN film deposited with bias voltage was higher than that without bias voltage. The reason is believed to be the existence of c-BN bonding in BN film and the higher density of film that deposited with the substrate bias voltage.

  • PDF

Study of Multi Anti-Reflection Coating Thin Film of Ferrule Facet Manufacture and Characteristics (광커넥터 패룰 단면의 다층 무반사 코팅 박막 제작 및 특성에 관한 연구)

  • Ki, Hyun-Chul;Yang, Mung-Hark;Kim, Sun-Hoon;Kim, Sang-Taek;Park, Kyung-Hee;Hong, Kyung-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.408-409
    • /
    • 2007
  • Ferrule function have connect Optical Communication Cable. But Ferrule have important role that is decided transmission efficiency and information quality. Key-point of detailed drawing of ferrule is Anti-Reflection. In the study Broadband Anti-Reflection coating Film was design for ferrule of optical connector and deposited in low temperature by Ion-Assisted Deposition system. Optical thin film materials($Ta_2O_5$, $SiO_2$) were manufactured Index and Film thickness. $Ta_2O_5$ index is 2.123 ~ 2.125 and $SiO_2$ is 1.44 ~ 1.442. Reflection Loss of film deposited on Ferrule is 30.1[dB].

  • PDF

Design and Characteristics of Anti-reflection Coating using Multi-layer Thin Film on the Ferrule Facet (다층 박막을 이용한 패럴 단면의 무반사 코팅 설계 및 특성)

  • Ki, Hyun-Chul;Yang, Mung-Hark;Kim, Seon-Hoon;Kim, Tea-Un;Kim, Hwe-Jong;Gu, Hal-Bon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.991-994
    • /
    • 2007
  • In this paper, we have designed the anti-reflection(AR) coating for $1400{\sim}1600$ nm wavelength range on the ferrule facet of optical connector. The low-temperature ion-assisted deposition was applied to AR coating on the ferrule facet in order to avoid damage of optical connector. We have measured the refractive index of coating film($Ta_2O_5\;and\;SiO_2$) using the ellipsometer and optimized the film thickness using the SEM and thickness measurement equipment. UV-VIS-NIR spectrophotometer is used to measure transmissivity of the AR coated ferrule facet. The refractive index of $Ta_2O_5\;and\;SiO_2$ is $2.123{\sim}2.125$ and $1.44{\sim}1.442$, respectively, for $1400{\sim}1600$ nm wavelength range. The transmissivity of the AR coated ferule facet is more than 99.8 % for $1425{\sim}1575$ nm wavelength range and more than 99.5 % for $1400{\sim}1600$ nm wavelength range. The return loss of the AR coated ferrule facet is 30.1 dB.

Negative Ion Generation Index according to Altitude in the Autumn of Pine Forest in Gyeongju Namsan (경주 남산 소나무림의 가을철 해발고도별 음이온 발생지수)

  • Kim, Jeong Ho;Yoon, Ji Hun;Lee, Sang Hoon;Choi, Won Jun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.4
    • /
    • pp.413-424
    • /
    • 2018
  • The study analyzed the effects of topographic structures and altitude in mountainous parks in Mt. Namsan in Gyeongju on the generation of anions. The temperature was at ridge ($9.82^{\circ}C$) > valley ($8.44^{\circ}C$), the relative humidity valley (59.01 %) > ridge (58.64 %), the solar radiation ridge ($34.40W/m^2$) > valley($14.69W/m^2$), the wind speed ridge (0.63m/s) > valley(0.37m/s), and the negative ion valley($636.81ea/cm^3$) > ridge($580.04ea/cm^3$). In the valley, the correlation with altitude was verified for the temperature, relative humidity, solar radiation, and negative ion generation in the valley. The relative humidity, solar radiation, and negative ion indicated a positive correlation while the temperature had a negative correlation. In the ridge, the correlation with altitude was verified for the temperature, relative humidity, wind speed, solar radiation, and negative ion generation. The relative humidity, solar radiation, and negative ion generation indicated a positive correlation while the temperature and wind speed had a negative correlation. The regression analysis showed the prediction equation of y=-0.006x+9.663 (x=altitude, y=temperature) in the valley and y=-0.009x+11.595 (x=altitude, y=temperature) in the ridge for the temperature, y=0.027x+53.561 (x=altitude, y=relative humidity) in the valley and y=0.008x+56.646 (x=altitude, y=relative humidity) in the ridges for the relative humidity, and y=0.027x+53.561 (x=altitude, y=negative Ion generation) in the valley and y= 0.008x+56.646 (x=altitude, y=negative Ion generation) in the ridge for the negative ion generation.

SiN film deposition using by a Pulsed-PECVD at room-temperature : Effect of Duty ratio on Ion energy and Refractive index (Pulsed-PECVD를 이용한 SiN 박막의 $SiH_4-NH_3$에서의 상온 증착: Duty rntio의 이온에너지와 굴절률에의 영향)

  • Kim, Su-Yeon;Kim, Byung-Whan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.221-222
    • /
    • 2009
  • SiN 박막을 Pulsed-PECVD를 이용하여 증착하였다. 박막특성으로는 굴절률, 플라즈마의 특성으로는 이온 에너지 분포를 duty ratio의 함수로 분석하였다. 50-100%의 범위에서 duty ratio의 감소에 따라 고 이온 에너지는 크게 증가하였으며, 반대로 저 이온 에너지는 감소되었다. 굴절률은 duty ratio의 감소에 따라 증가되었으며, 모든 duty ratio의 변화에서 1.75-1.81 사이에서 변화하였다. 40-90%의 duty ratio에서 저 이온 에너지 플럭스보다 고 이온 에너지 플럭스가 높았다. 한편, 굴절률의 변화는 $N_h$의 변화에 가장 밀접하게 연관되어 있음을 확인할 수 있었다.

  • PDF

Improving Process Capability by 2-Way Classification (2원배치법(元配置法)을 이용한 공정능력(工程能力)의 향상(向上))

  • Gu, Bon-Cheol;Song, Seo-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.17 no.2
    • /
    • pp.64-69
    • /
    • 1989
  • This paper aims at analyzing the process capability and at determining an optimal condition by experimental designs using the 2-way classification with repitition in order to maintain lower Nacl content and to refine both of a very small quantity of fatty acid and various magnetic ions in the glycerin to use ion exchange resin treatment process. An optimal condition of each level combination in both of passing temperature of cation exchange resin($A_1$, $A_2$, $A_3$) and of anion exchange resin($B_1$, $B_2$, $B_3$) is $A_3B_3$. The process capability index is improved from 0.63 to 1.40 and is interpreted as a desirable state. This analysis of process capability by experimental designs will contribute to improving productivity and quality of products.

  • PDF

A Study on the Reversibility Scalar Phenomena in Amorphous Chalcogenides (비정질 칼코게나이드에서 광유기 스칼라 현상의 가역성에 관한 연구)

  • 박수호;정진만;이현용;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.31-34
    • /
    • 1997
  • A reversible scalar phenomena in amorphous As$_{40}$ Ge$_{10}$ Se$_{15}$ S$_{35}$ have been investigated by blue-pass-filtered Hg lamp and He-Ne laser. Annealing causes the shift of the absorption edge to shelter wavelengths approximately 0.17ev, also illumination moves it to longer wavelengths about 0.05 ~ 0.07eV and it increases the refractive index maximum 0.3. Therefore the thermalbleaching(TB) and photodarkening(PD) effects have been understood by the results related to optical absorption characteristics. TB could be estimated as increasing the stabilization of amorphous chalcogenide films since absorption slope of extended regions(U) was not changed by annealing. On the other hand, PD could be understood as due to the enhancement of disorder since the slope of Urbach’s tail(1/F) around an absorption edge were decreased by illumination.ion.n.

  • PDF

A Study on GIS Methods for Estimating "Index for Populat ion Generator" Based on socio-economic factor (인문사회 공간정보를 활용한 유동인구지수 추정)

  • Han, Jung-Sun;Kim, Han-Gook
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2009.04a
    • /
    • pp.262-264
    • /
    • 2009
  • 국내 마케팅 시장은 전체 분야에 걸쳐 출혈경쟁이 이뤄지고 있다. 이와 같은 환경에서 기업들이 올바른 의사결정을 통해 경쟁력을 확보하려면 시장의 잠재력을 정량적으로 파악하는 노력이 필요하다. 특히, 배후지의 인구, 직장인, 그리고 유동인구 규모 등은 시장의 잠재력을 판단하는 기본 정보다. 배후지의 인구와 직장인 정보는 국가통계 자료 등을 활용하거나 기타 추정방법에 의해 산정되어 활용되고 있다. 하지만, 유동인구에 관한 정보는 실제 거리에 나가 인구를 측정하여 활용하는 방안 외에는 마땅한 추정방법이 없는 실정이다. 이러한 이유로 유동인구가 매출에 직접적인 영향을 주는 기업들은 많은 시간과 인력을 투입하여 유동인구 수를 측정하고 있다. 하지만, 비용적인 측면에서 한계가 있다. 본 연구에서는 Point 기반의 인문사회 Spatial DB를 활용하여 전국단위의 유동인구를 추정하는 방법론을 제안했다. 또한, 유동인구 정보에는 연령 및 성별 비율까지 추정하여 다양한 활용이 가능하도록 하였다.

  • PDF

Effect of pH and Iron/Manganese Ion on TiO2 Mediated Photocatalytic Inactivation of Index Microorganisms (LNAPL을 이용한 지중 산소전달 향상: (I) Abiotic Condition)

  • Ha, Jeong-Hyub;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.307-311
    • /
    • 2004
  • The objective of this work is to evaluate the hypothesis that a good technique for supplying oxygen to the saturated zone in the presence of light nonaqueous phase liquid (LNAPL) pool contamination at the water table is to pass air through the unsaturated zone above the pool. This hypothesis was evaluated in experimental studies performed using a bench-scale, sand-tank reactor, Steady-state abiotic experiments in the sand-tank reactor with air flowing through the reactor headspace demonstrated that oxygen supply through the water table interface into the saturated zone was enhanced when an LNAPL (dodecane) pool was present at the water table. These experimental results confirmed the hypothesis that an LNAPL pool can serve as a high concentration oxygen source to the oxygen-limited area beneath the pool and, as a result, enhance the in situ biodegradation rate.