• Title/Summary/Keyword: Increasing temperature characteristics

Search Result 2,362, Processing Time 0.03 seconds

A Study on Temperature Dependency of Strength and Deformation Behavior of Rocks (암석의 강도 및 변형거동의 온도의존성에 관한 연구)

  • 이형원;이정인
    • Tunnel and Underground Space
    • /
    • v.6 no.2
    • /
    • pp.101-121
    • /
    • 1996
  • The thermomechanical characteristics of rocks such as temperature dependency of strength and deformation were experimentally investigated using Iksan granite, Cheonan tonalite and Chung-ju dolomite for proper design and stability analysis of underground structures subjected to temperature changes. For the temperature below critical threshold temperature $T_c$, the variation of uniaxial compressive strength, Young's modulus, Brazilian tensile strength and cohesion with temperature were slightly different for each rock type, but these mechanical properties decreased at the temperatures above $T_c$ by the effect of thermal cracking. Tensile strength was most affected by $T_c$, and uniaxial compressive strength was least affected by $T_c$. To the temperature of 20$0^{\circ}C$ with the confining prressure to 150 kg/$\textrm{cm}^2$, failure limit on principal stress plane and failure envelope on $\sigma$-$\tau$ plane of Iksan granite were continuously lowered with increasing temperature but those of Cheonan tonalite and Chung-ju dolomite showed different characteristics depending on minor principal stress on principal stress plane and normal stress on $\sigma$-$\tau$ plane. The reason for this appeared to be the effect of rock characteristics and confining pressure. Young's modulus was also temperature and pressure dependent, but the variation of Young's modulus was about 10%, which was small compared to the variation of compressive strength. In general, Young's modulus increased with increasing confining pressure and increased or decreased with increasing temperature to 20$0^{\circ}C$ depending on the rock type.

  • PDF

Analysis of Power Pattern According to Irradiation for Photovoltaic Generation System (태양광발전 시스템의 일사량에 따른 전력 패턴 분석)

  • Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.602-608
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. As I-V characteristics according to a temperature range of 10~50[$^{\circ}C$], the area of I-V characteristics were increased with an increase in temperature. Since this area corresponds to the power, output power is thought to have increased with temperature. As output power characteristics according to a temperature range of 10~50[$^{\circ}C$], output power was increased with an increase in temperature. Since output power increases with temperature increase, the result corresponds well to the related equation on temperature and output power. As I-V characteristics according to a irradiation range of 100~900 [$W/m^2$], voltage and current were increased with an increase in irradiation. The result is thought of as an increase in output power with increasing irradiation. As output power characteristics according to a irradiation range of 100~900 [$W/m^2$], output power was increased with increasing irradiation. This result corresponds well to the related equation on irradiation and output power.

Analysis of Electrical Characteristics of Oxide Semiconductor of ZnO, SnO2 and ZTO (ZnO, SnO2, ZTO 산화물반도체의 전기적인 특성 분석)

  • Oh, Teresa
    • Korean Journal of Materials Research
    • /
    • v.25 no.7
    • /
    • pp.347-351
    • /
    • 2015
  • To study the characteristics of ZTO, which is made using a target mixed $ZnO:SnO_2=1:1$, the ZnO and $SnO_2$ were analyzed using PL, XRD patterns, and electrical properties. Resulting characteristics were compared with the electrical characteristics of ZnO, $SnO_2$, and ZTO. The electrical characteristics of ZTO were found to improve with increasing of the annealing temperature due to the high degree of crystal structures at high temperature. The crystal structure of $SnO_2$ was also found to increase with increasing temperatures. So, the structure of ZTO was found to be affected by the annealing temperature and the molecules of $SnO_2$; the optical property of ZTO was similar to that of ZnO. Among the ZTO films, ZTO annealed at the highest temperature showed the highest capacitance and Schottky contact.

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Adsorption Characteristics of Volatile Organic Compounds-BTX on Activated Carbon Fiber (활성탄소섬유를 이용한 휘발성유기화합물 (VOCs-BTX)의 흡착특성)

  • 김한수;박영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.805-812
    • /
    • 1999
  • Adsorption characteristics of volatile organic compounds(VOCs) by activated carbon fiber(ACF) were investigated using a continuous system for benzene, toluene, xylene(BTX) generation. Studied characteristics for adsorption were equilibrium capacity, accumulative adsorption, and breakthrough curve. Operating variables were adsorption temperature(25~45$^{\circ}C$) and partial pressure(1.2~12 mmHg) of BTX. The experimental results show that the adsorption equilibrium capacity increases with increasing partial pressure of BTX and decreases with increasing temperature. It was also found that the break point was decreased with increasing partial pressure, temperature and gas flow rate due to an effect of mass transfer of adsorbate.

  • PDF

Microstructure and Electrical Characteristics of ZnO-Bi2O3 Ceramics (ZnO-Bi2O3계 세라믹스의 미세구조 및 전기적 특성)

  • 이승주;한상목
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.6
    • /
    • pp.645-654
    • /
    • 1988
  • The microstructure and electrical characteristics of ZnO-Bi2O3 ceramics containing 5mol% Bi2O3 have been studied in relation to sintering temperature and mode. The distribution and thickness of Bi2O3 intergranular layer was varied with sintering temperature and mode. Intergranular layer was more homogeneous with increasing sintering temperature, when sintering by direct heating and rapid cooling mode showed the best distribution of intergranular layer. These microstructural changes affected electrical characteristics directly, at 140$0^{\circ}C$ and C mode obtained high value of electrical resistivity and nonlinear exponent. Varistor voltage decreased with increasing sintering temperature, increased with decreasing holding time at high temperature. Barrier voltage obtained by calculation was about 1.5V.

  • PDF

Oxygen Transfer Characteristics of an Ejector Aeration System

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2012
  • The objective of this study was to investigate the oxygen transfer characteristics of an ejector aeration system. In order to evaluate the oxygen transfer performance of the ejector aeration system, a comparative experiment was conducted on a conventional blower aeration system. The effect of entrained air flow rate and aerating water temperature on the oxygen transfer efficiency was investigated. The dissolved oxygen concentration increased with increasing entrained air flow rate, but decreased with increasing aerating water temperature for two aeration systems. The volumetric mass transfer coefficient increased with increasing entrained air flow rate and with increasing aerating water temperature for both aeration systems. The average mass transfer coefficient for the ejector aeration system was about 20% and 42% higher than that of the blower aeration system within the experimental range of entrained air flow rates and aerating water temperatures.

Variation Characteristics of Hourly Atmospheric Temperature Throughout a Winter (동계 시각별 외기온의 변동 특성에 관한 연구)

  • Lee, Seung-Eon;Shon, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 1992
  • Identifying characteristics of heating and cooling systems requires estimation of thermal load of specific time interval, especially in cases that its system is operated intermittently, by using thermal storage, of in a partial load condition. Estimating the thermal load, however, needs to forecast hourly weather data variation. Hence, this paper attempts to examine characteristics of hourly ourdoor temperature variation as a preliminary research for the mathematical modeling of the hourly weather variation. Speculating characteristics of daily minimum and maximum temperature occurances, hourly outdoor temperature variation, and daily temperature differences in the increasing range ($07h{\sim}15h$) and decreasing range($15h{\sim}07h$), we were able to analyze changing patterns of daily temperature differences in each range in terms of daily solar amount, cloud ratio, and other weather data. Results from the multiple regression analysis enables us to conclude that daily differences in the increasing range are strongly affected last night temperature itself while the other range's differences are influenced by many weather data, which are solar amount, the variation of cloud, and the maximum temperature of the previous day.

  • PDF

A Study on the Characteristics of Heat Transfer in Quadrangle Duct with Solar Absorber Plate (태양열 집열면이 있는 4각 덕트 내의 열전달 특성에 관한 연구)

  • 고동국;조대진;윤석주;박상규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1014-1022
    • /
    • 2002
  • This paper analyzed the characteristics of heat transfer in quadangle duct with absorber plate by solar radiation. Effects o( Reynolds number on increasing temperature at outlet for variation of absorber plate temperature were analyzed by using numerical analysis technique. And also the effects of turbulent intensity of inlet flow on increasing temperature at outlet for various duct height and effects of inlet aspect ratio of quadrangle duct and position of heating surface on the outlet temperature were analysed. As the results, Outlet temperature was greatly influenced in low Reynolds number. And the highest outlet temperature distribution appeared on the inlet aspect ratio 2 because of the buoyancy effect.

Computational Study of the MILD Combustion and Pollutant Emission Characteristics in Jet Flow Field (제트 유동장에서의 마일드 연소 및 오염물질 배출특성에 관한 전산해석 연구)

  • Kim, Yu Jeong;Song, Keum Mi;Oh, Chang Bo
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.60-65
    • /
    • 2012
  • The MILD combustion and pollutant emission characteristics were investigated computationally. The temperature of supplying air-stream and mixing rate (${\Omega}$) of exhaust gas in the air-stream were adjusted to investigate the effects of those parameters on the MILD combustion in jet flow field. The emission indices for NO (EINO) and CO (EICO) were introduced to quantify the amount of those species emitted from the combustion. The high-temperature region disappeared gradually as the mixing rate increased for fixed air-stream temperature. The EINO increased as the air-stream temperature became higher for fixed mixing rate, and the EINO decreased dramatically with increasing the mixing rate for each air-stream temperature condition. The EICO also decreased with increasing the mixing rate and it was nearly independent of air-stream temperature except for near ${\Omega}$ = 0.7. It was found that the CO supplied in the air-stream can be destroyed in the MILD combustion over the certain mixing rate.