• Title/Summary/Keyword: Increased Head

Search Result 1,737, Processing Time 0.028 seconds

Muscle Properties Analysis of SCM Muscle using Smartphone postures (자세유형별 스마트폰 사용에 따른 목빗근의 근육 속성 분석)

  • Kim, In-Suk;Kim, Kyun-Young;Park, Sang-Gwan;Choi, Young-Woo;Noh, Han-Na;Kim, Jin-A
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.991-997
    • /
    • 2017
  • Purpose. The purpose of this study was to muscle properties analysis of SCM(sternocleidomastoid) Muscle according to posture type when using smartphone. Methods. This study was conducted on 73 college students who are using smartphone. Subjects were analyzed myotonPRO to confirm, prone posture group, stand posture group, drop head above $45^{\circ}$in sit posture on a chair group and drop head below $45^{\circ}$in sit posture on a chair group were measured SCM muscle. The myotonPRO were measured one measurer, total 3 times. Comparative analysis of the each groups were investigated of SCM muscle properties. Results. We found that Frequency, Stiffness, Creep and Relaxation were appeared difference in each posture. F index was increased at drop head below $45^{\circ}$group than stand posture group. S index was increased at drop head above $45^{\circ}$group than prone posture group. C index was decreased at drop head below $45^{\circ}$group and drop head above $45^{\circ}$group than prone posture group. R index was decreased at drop head above $45^{\circ}$group than prone posture group. Conclusions. The muscle properties were appeared difference in each posture of SCM muscle using smartphone.

Changes of Minute Blood Flow in the Large Vessels during Orthostasis and Antiorthostasis, before and after Atropine Administration (체위변화가 두부 및 하지의 분시혈류량에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.139-153
    • /
    • 1985
  • The passive tilt has been performed to study the orthostasis on the cardiovascular system. The orthostasis due to upright tilt was demonstrated as follows: the venous return, cardiac output and systemic arteiral blood pressure were decreased, whereas there was concomitant increase of heart rate, through the negative feedback mediated by such as the baroreceptor . Previous investigators have suggested that the tolerance to the orthostasis could he increased by blocking the cholinergic fiber with atropine which prevented vasodilation and bradycardia through the vasovagal reflex during the orthostasis. However, this hypothesis has not been clearly understood. This study was attempted to clarify the effect of atropine on the tolerance of the cardiovascular system to the upright and head-down tilt, and to investigate the change of the blood flow through head and lower leg with Electromagnetic flowmeter in both tilts before and after atropine state. Fourteen anesthetized dogs of $10{\sim}14kg$ were examined by tilting from supine position to $+77^{\circ}$ upright position (orthostasis), and then to $-90^{\circ}$ head-down position (antiorthostasis) for 10 minutes on each test. And the same course was taken 20 minutes after intravenous administration of 0.5mg atropine. The measurements were made of the blood flow(ml/min.) on the carotid artery, external jugular vein, femoral artery and femoral vein. At the same time pH, $PCO_2$, $PO_2$ and hematocrit (Hct) of the arterial and venous blood, and heart rate(HR) and respiratory rate (RR) were measured. The measurements obtained from upright and head-down tilt were compared with those from supine position. The results obtained are as follows: In upright tilt, the blood flow both on the artery and the vein through head and lower leg were decreased, however the decrement of blood flow through the head was greater than the lower leg And the atropine attenuated the decrement of the blood flow on the carotid artery, but not on the vessels of the lower leg. HR was moderately increased in upright tilt, but slightly in head-down tilt. The percent change of HR after the atropine administration was smaller than that before the atropine state in both upright and head-down tilts. Before the atropine state, RR was decreased in upright tilt, whereas increased in head-down tilt. However after the atropine state, the percent change of RR was smaller than that of before the atropine state in both upright and head-down tilts. In upright tilt, venous $PCO_2$ was increased, but arterial $PO_2$ and venous $PO_2$ were slightly decreased. Hct was increased in both upright and head-down tilts. The findings of blood $PCO_2$, $PO_2$ and Hct were not interferred by the atropine. In conclusion, 1;he administration of atropine is somewhat effective on improving the cardiovascular tolerance to postural changes. Thus, atropine attenuates the severe diminution of the blood flow to the head during orthostasis, and also reduces the changes of HR and RR in both orthostasis and antiorthostasis.

  • PDF

Role of Centromere Protein H and Ki67 in Relapse-free Survival of Patients after Primary Surgery for Hypopharyngeal Cancer

  • Wang, Jun-Xi;Zhang, Ying-Yao;Yu, Xue-Min;Jin, Tong;Pan, Xin-Liang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.821-825
    • /
    • 2012
  • Purpose: Centromere protein H (CENP-H) and Ki67 are overexpressed in some malignancies, but whether they are predictors of survival after primary resection for hypopharyngeal squamous cell carcinoma (HSCC) remains unknown. Methods: We assessed immunohistochemical expression of CENP-H and Ki67 in 112 HSCC specimens collected between March 2003 and March 2005 for analysis by clinical characteristics. The Kaplan-Meier method was used to analyze relapse-free survival and logistic multivariate regression to determine risk factors of relapse-free survival. Cholecystokinin octapeptide assays and flow cytometry were used to examine cell proliferation and apoptosis after siRNA inhibition of CENP-H in HSCC cells. Results: Overall, 50 (44.6%) HSCC specimens showed upregulated CENP-H expression and 69 (61.6%) upregulated Ki67. An increased CENP-H protein level was associated with advanced cancer stage and alcohol history (P=0.012 and P=0.048, respectively) but an increased Ki67 protein level only with advanced cancer stage (P=0.021). Increased CENP-H or Ki67 were associated with short relapse-free survival (P<0.001 or P=0.009, respectively) and were independent predictors of relapse-free survival (P=0.001 and P=0.018, respectively). siRNA knockdown of CENP-H mRNA inhibited cell proliferation and promoted cancer cell apoptosis in vitro. Conclusions: Upregulated CENP-H and Ki67 levels are significantly associated with short relapse-free survival in HSCC. These factors may be predictors of a relapsing phenotype in HSSC cases.

Effects of Volute Throat Enlargement and Fluid Viscosity on the Performance of an Over Hung Centrifugal Pump

  • Khoeini, Davood;Riasi, Alireza;Shahmoradi, Ali
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.30-39
    • /
    • 2017
  • In the current study, identifying regimes and behaviors of the various viscous fluids in a typical horizontal single-stage centrifugal pump and improving its performance by enhancing volute throat area have been surveyed numerically and experimentally. Indeed the initial pump had insufficient head at BEP (Best Efficient Point) in relevant applications. In order to solve this problem, the method of increasing the volute throat area on the prototype was used in steps and eventually the increased head values have been achieved. Then modified centrifugal pump, that has been constructed based on the modified control volume from numerical results, has been tested thoroughly. The maximum head and efficiency discrepancy between numerical and experimental results in BEP were 1.4 and 2.6% respectively. The effects of viscous fluids, from 1 cSt to 500 cSt, on the performance curves of centrifugal pump have been investigated as well and results showed that viscous fluids has significant effect on them. Indeed the highest head and efficiency in the same conditions at BEP has been obtained in viscosity 1 cst which was by 19.2% and 44% greater than the viscosity 500 cSt. It is also found that the highest viscous fluid had the highest energy consumption as the absorbed power of highest viscous fluid, 500 cSt, increased up to approximately 55% above the lowest viscous fluid, 1 cSt, values.

Effects of Occipital Bone Stimulation by Cervical Stabilizing Exercise on Muscle Tone, Stiffness, ROM and Cervical Lordosis in Patient with Forward Head Posture: Single System Design

  • Park, Si Eun;Lee, Jun Cheoul;Choi, Wan Suk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.989-993
    • /
    • 2016
  • The purpose of this study was to investigate the effects of occipital bone stimulation by cervical stabilizing exercise on the muscle tone, stiffness, ROM, and cervical lordosis in patient with forward head posture(FHP). This study was a case study of a single patient with forward head posture. This study used a ABA' design, A and A' were the baseline phases and B was the intervention phase. The intervention was occipital bone stimulation by cervical stabilization exercise. It was administered once daily for 7 days. The therapist kept hands together, and placed the two index fingers under the subject's occipital bone. The subject performed the chin-in exercise with a maximum isometric contraction for 20 sec.The exercise was implemented by performing the movements 10 times as a set and repeating the set three times. The muscle tone was not significantly changed after intervention. However, the stiffness was decreased and lasted the effect lasted without intervention. The cervical flexion angle was increased, but the cervical extension angle was not significantly changed after the intervention. The left and right lateral flexion angles were increased and the effect lasted without any intervention. However, the left and right rotation angles were significantly changed after the intervention. Cervical lordosis increased not from $37^{\circ}$ to $41^{\circ}$ after the intervention. These results suggest that occipital bone stimulation by cervical stabilizing exercise had a positive effect on cervical stiffness, flexion and lateral flexion ROM, and lordosis in a patient with forward head posture.

Changes in Blood pH, $Pco_2$ and $Po_2$ During Passive Tilt (체위 변화시의 혈액 pH, $Pco_2$$Po_2$의 변화)

  • Jun, Sang-Yun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.12 no.1_2
    • /
    • pp.35-40
    • /
    • 1978
  • To evaluate orthostatic brain hypoxia from the passive tilt, anesthetized dogs were tilted from supine to $90^{\circ}C$ upright and $90^{\circ}C$ head down position. Blood pH, $Pco_2$ and $Po_2$ changes during tilt were measured on 8 dogs. Respiratory rate was decreased in upright position and increased in head down position comparing to that in rte horizontal position. pH in arterial blood was increased in upright position and decreased in venous blood comparing to that in the horizontal position. No significant changes were found in the head down position. $Pco_2$ of arterial and venous blood was decreased both in upright and head down. position A significant decrease was found in the head down position. $Po_2$ in arterial blood was increased both in the upright and head down position. However, it was decreased in the venous blood. The cause of increased $Po_2$ in arterial blood seemed to do due to hyperventilation and the cause of decreased $Po_2$ in venous blood was thought to be due to increased $O_2$ consumption of animals during the tilt.

  • PDF

Optimization of head mass for tonpilz transducer using finite element method (유한요소법을 이용한 tonpilz 트랜스듀서의 head mass 최적화)

  • Seo, Jin-Won;Choi, Kyoon;Lee, Ho-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.4
    • /
    • pp.140-144
    • /
    • 2015
  • Effects of the shape, the size and the material of head mass on performances of tonpilz transducer were studied with a finite element method. The shape of head mass was changed with an angle between symmetric axis and side of head mass of transducer from 0 to 60 degree. As a result of the simulations, the bandwidth leached to 86.4 % at 35.5 degree in case of Al head mass. The size of head mass showed a decrease in the power of transducer with little change of bandwidth. For the Ti head mass, the transmitted power showed 100 % increase with a bandwidth of 88.1 % even though the weight of the head mass increased to 167 % of Al. This can be attributed to the mechanical properties like elastic modulus of Ti relative to Al.

Influence of Forward Head Posture on Electromyography Activity of Hyoid Muscles During Mouth Opening

  • Song, Jae-Ik;Kang, Sun-Young;Park, Joo-Hee;Cynn, Heon-Seock;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.103-109
    • /
    • 2015
  • Although the relationship between temporomandibular disorder and forward head posture (FHP) is controversial, it is generally accepted that altered head posture can affect mandible position and masticatory muscles activity. Because suprahyoid (SH) and infrahyoid (IH) muscles are stretched by increased passive tension in FHP, this study investigated their activity during mouth opening in FHP compared to neutral head posture (NHP). Twenty healthy subjects (10 males and 10 females) participated in this study. Head postures were evaluated with a cervical range of motion instrument. Electromyography (EMG) activity of bilateral SH and IH muscles was measured while an open mouth was maintained at each head posture. Paired t-test was used to identify significant differences in normalized EMG activity between head postures. Statistical significance was set at .01. Results showed the normalized EMG activity of SH and IH muscles were significantly lower in FHP compared to NHP. This finding indicates that FHP affects the EMG activity of hyoid muscles when they are stretched.

Factors Affecting Wet-Paddy Threshing Performance (탈곡기의 제작동요인이 벼의생탈곡성능에 미치는 영향)

  • 남상일;정창주;류관희
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • Threshing operation may be one of the most important processes in the paddy post-production system as far as the grain loss and labor requirement are concerned . head-feeding type threshers commercially available now in Korea originally were developed for threshing dry paddy in the range of 15 to 17 % in wet basis. However, threshing wet-paddy with the grain moisture content above 20 % has been strongly recommended, especially for new high-yielding Indica -type varieties ; (1) to reduce high grain loss incurred due to the handling operations, and (2) to prevent the quantitative and qualitative loss of milled -rice when unthreshed grains are rewetted due to the rainfall. The objective of this study were to investigate the adaptability of both a head-feeding type thresher and a throw-in type thresher to wet-paddy , and to find out the possiblilities of improving the components of these threshers threshing. Four varieties, Suweon 264 and Milyang 24 as Tongil sister line varieties, minehikari and Jinhueng as Japonica-type varieties, were used at the different levels of the moisture content of grains. Both the feed rate and the cylinder speed were varied for each material and each machine. The thresher output quality , composition of tailing return, and separating loss were analyzed from the sampels taken at each treatment. A separate experiment for measurement opf the power requirement of the head-feeding type thresher was also performed. The results are summarized as follows : 1. There was a difference in the thresher output quality between rice varieties. In case of wet-paddy threshing at 550 rpm , grains with branchlet and torn heads for the Suweon 264 were 12 % and 7 % of the total output in weight, respectively, and for the Minehikari 4.5 % and 2 % respectively. In case of dry paddy threshing , those for the Suweon 264 were 8 % and 5% , and for the Minehikari 4% and 1% respectively. However, those for the Milyang 23 , which is highly susceptable to shattering, were much lower with 1 % and 0.5% respectively, regardless of the moisture content of the paddy. Therefore, it is desirable to breed rice varieties of the same physical properties as well as to improve a thresher adaptable to all the varieties. Torn heads, which increased with the moisture content of rall the varieties except the Milyang 23 , decreased as the cylinder speed increased, but grains with branchlet didnt decrease. The damaged kernels increased with the cylinder speed. 3. The thresher output quality was not affected much by the feed rate. But grains with branchlet and torn heads increased slightly with the feed rate for the head-feeding type thresher since higher resistance lowered at the cylinder speed. 4. In order to reduce grains with branchlet and torn heads in wet-paddy threshing , it is desirable to improve the head-feeding type thresher by developing a new type of cylinder which to not give excess impact on kernels or a concave which has differenct sizes of holes at different locations along the cylinder. 5. For the head-feeding type thresher, there was a difference in separating loss between the varieties. At the cylinder speed of 600 rpm the separating losses for the Minehikari and the Suweon 264 were 1.2% and 0.6% respectively. The separating loss of the head-feeding type thresher was not affected by the moisture content of paddy while that of the Mini-aged thresher increased with the moisture content. 6. From the analysis of the tailings return , to appeared that the tailings return mechanism didn't function properly because lots of single grains and rubbishes were unnecessarily returned. 7. Adding a vibrating sieve to the head-feeding type thresher could increase the efficiency of separation. Consequently , the tailing return mechanism would function properly since unnecessary return could be educed greatly. 8. The power required for the head-feeding type thresher was not affected by the moisture content of paddy, but the average power increased linearly with the feed rate. The power also increased with the cylinder speed.

  • PDF

Reynolds Number Effect on Regenerative Pump Performance in Low Reynolds Number Range

  • Horiguchi, Hironori;Yumiba, Daisuke;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • The effect of Reynolds number on the performance of a regenerative pump was examined in a low Reynolds number range in experiment. The head of the regenerative pump increased at low flow rates and decreased at high flow rates as the Reynolds number decreased. The computation of the internal flow was made to clarify the cause of the Reynolds number effect. At low flow rates, the head is decreased with increasing the Reynolds number due to the decrease of the shear force exerted by the impeller caused by the increase of leakage and hence local flow rate. At higher flow rates, the head is increased with increasing the Reynolds number with decreased loss at the inlet and outlet as well as the decreased shear stress on the casing wall.