• Title/Summary/Keyword: Increase diameter

Search Result 2,349, Processing Time 0.031 seconds

A Study on the Influence Coaxial Parallel Magnetic Field upon Plasma Jet (II) (Plasma Jet의 동축평행자계에 의한 영향에 관한 연구 2)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.22 no.5
    • /
    • pp.19-32
    • /
    • 1973
  • This paper treats with some of plasma jet behaviors under magnetic field for the purpose of controlling important characteristics of plasma jet in the practices of material manufacturings. Under the existence and non-existence of magnetic field, the pressure distribution, flame length, stability and noise of plasma jet are comparatively evaluated in respect of such parameters as are current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle. The results are as follows: 1) the pressure, the length and the noise of plasma jet rise gradually with the increase of are current, and have high values under identical arc current as the diameter of nozzle increases, but reverse phenomenon tends to appear in the noise. 2) The pressure, the flame length and the noise increase with the increased quantity of argon flow, and the rising slope of noise is particularly steep. Under magnetic field, the quantity of argon flow in respect of flame length has the critical value of 80(cfh). 3) The pressure and length of flame decrease with small gradient value as the length of gap increases, but the noise tends to grow according to the increase of nozzle diameter. 4) The pressure and the length of jet flame decrease inversly with the increase of magnetic flux density, which have one critical value in the 100 amps of arc current and two values in 50 amps. The pressure of jet flame can be below atomospher pressure in strong magnetic field. 5) "The constriction length of nozzle has respectively the critical value of 6(mm) for pressure and 23(mm) for the length of flame. 6) Fluctuations in the wave form of voltage become greater with the increase of argon flow and magnetic flux density, but tends to decrease as arc current increases, having the frequency range of 3-8KHz. The wave form of noise changes almost in parallel with that of voltage and its changing value increases with argon flow, arc current and magnetic flux density, having the freuqency range of 6-8KHz. The fluctuation of jet presurre is reduced with the increase of argon flow and magnetic flux density and grows with arc current.rent.

  • PDF

Innovative approach to determine the minimum wall thickness of flexible buried pipes

  • Alzabeebee, Saif;Chapman, David N.;Faramarzi, Asaad
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.755-767
    • /
    • 2018
  • This paper uses a finite element based approach to provide a comprehensive understanding to the behaviour and the design performance of buried uPVC pipes with different diameters. It also investigates pipes with good and poor haunch support and proposes minimum safe wall thicknesses for these pipes. The results for pipes with good haunch support showed that the maximum pipe wall stress and deformation increase as the diameter increased. The results for pipes with poor haunch support showed an increase in the dependency of the developed vertical displacement on the haunch support as the diameter or the backfill height increased. Additionally, poor haunch support was found to increase the soil pressure, with the effect increasing as the diameter increased. The design of uPVC pipes for both poor and good haunch support was found to be governed by critical buckling. A key outcome is a new design chart for the minimum wall thickness, which enables the robust and economic design of buried uPVC pipes. Importantly, the methodology adopted in this study can also be applied to the design of flexible pipes manufactured from other materials, buried under different conditions and subjected to different loading arrangements.

A Study on the Entropy Generation of Single Fin-Tube Heat Exchanger (단일 핀-관 열교환기에서 엔트로피 생성에 관한 연구)

  • Pak, Hi-Yong;Lee, Kwan-Soo;Kim, Byoung-Kue
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 1990
  • The entropy generation rate in a fin-tube heat exchanger is investigated as a basis for thermodynamic optimization associated with single fin-tube heat exchanger. The entropy generation (irreversibility)analysis is used to find the optimum design factor and investigate total entropy generation, optimum dimensions of fin length, tube inner and outer diameters, and fin spacing on the variation of design factors. The results of this study are as follows: As the outer diameter increases, optimum !in spacing and fin length increase but the entropy generation and optimum inner diameter decrease; As fin thickness increases, the entropy generation of system and optimum fin spacing increase; As fin length increases, entropy generation and optimum outer diameter increase.

  • PDF

The Effect of Diameter and Prehole Clearance for Wooden Dowel on The Withdrawal Loads of Domestic Wood (국산재에 대한 나무못 직경과 천공 여척이 나무못 유지력에 미치는 영향)

  • Cha, Jae Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.736-742
    • /
    • 2016
  • Wooden dowels are commonly used to join the wooden members together in many types of structures, But little information is available concerning their holding properties in domestic wood. This study was performed to determine the withdrawal loads and strengths on the effect of diameter of dowel and hole clearance. The test block was manufactured from 15 mm thick korean red pine and korean pine. The dowel was manufactured 6, 8 and 10 mm diameters from korean castanea, korean pine and tuliptree. Research reported here indicates that withdrawal loads increase, but withdrawal strengths decrease, in a linear fashion as the dowel diameter increases. This study also indicates that dowel withholding load and strength increase in a linear fashion as a hole clearance decreases.

An Experimental Study on the CCFL in Narrow Annular Gaps with Large Diameter (곡률 반경이 큰 환상관 간극에서 CCFL에 대한 실험 연구)

  • Lee, Seung-Jin;Jeong, Ji-Hwan;Park, Rae-Joon;Kim, Sang-Baik;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.795-800
    • /
    • 2000
  • A CCFL(Counter Current Flow Limit) test have been performed in narrow annular gaps with large diameter, because it has been confirmed that the CCFL phenomena affected the critical power in hemispherical narrow gap geometries from the SONATA(Simulation Of Naturally Arrested Thermal Attack)-IV (In-Vessel)/VISU(Visualization)-II experiments. The objectives of the CCFL experiments are to investigate the small gap sizes(1, 2mm) effect on CCFL under the large diameter condition and to confirm the findings of the VISU-II study that global dryout in hemispherical narrow gaps was induced by the CCFL. The test section was made of acrylic resin to allow visual observation on the two-phase flow behaviors inside annular gaps. It was observed from visualization that a part of water supplied was accumulated in the upper plenum and a significant increase in the differential pressure across the gap was occurred, which was the definition of the CCFL occurrence in this experimental study. From the experimental results in annular gap with large diameter it can be known that an increase in the differential pressure was not big at small air flow-rates. When the CCFL was occurred, the differential pressure across gaps was increased significantly and a water accumulated in the upper plenum. The occurrence of CCFL was correlated using the Wallis parameter.

  • PDF

A Study on the Behavior of Droplets Colliding with Parallel Wires (평행 와이어와 충돌하는 액적 거동에 관한 연구)

  • Na, J.K.;Noh, D.H.;Jung, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.26 no.3
    • /
    • pp.149-156
    • /
    • 2021
  • In this study, the behavior of the droplet colliding with parallel wires was analyzed by time-delay photography. The impact behavior modes and the critical capture speed were analyzed by changing fluids, the droplet velocity, the wire diameter and the distance between wires. Seven typical modes of impacting droplet on parallel wires were observed. The tendency of mode change was generally similar when the wire diameter was changed, but the increase of the wire diameter caused the increase of the droplet velocity at which the mode changed. The modes at the highest droplet velocity were the splitting mode when the wires were closest, the passing and splitting mode in the middle, and the passing mode when the wires were farthest apart. The critical capture speed increased as the wire diameter increased and the distance between wires decreased. The ethanol droplet showed the lowest critical capture speed.

A Numerical Study on the Steady and Pulsatile Flow with Various Diameter Ratios of Abdominal Aortic Aneurysm (복부대동맥류의 직경비에 따른 정상유동 및 맥동유동에 관한 수치적 연구)

  • Moh, Jeong-Hah;Park, Sang-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.920-928
    • /
    • 2003
  • The objective of the present study was to investigate the characteristics of flow and wall shear stress under steady and pulsatile flow in the aneurysm. The numerical simulation using the software were carried out for the diameter ratios ranging from 1.5 to 3.0, Reynolds number ranging from 900 to 1800 and Womersley number, 15.47. For steady flow, it was shown that a recirculating vortex occupied the entire bulge with its core located closer to the distal end of the bulge and the strength of vortex increased with increase of the Reynolds number and diameter ratio. The position of a maximum wall shear stress was the distal end of the aneurysm regardless of the Reynolds number and diameter ratios. For the pulsatile flow, a recirculating flow at the bulge was developed and disappeared for one period and the strength of vortex increased with the diameter ratio. The maximum values of the wall shear stress increased in proportion to the diameter ratio. However, the position of a maximum wall shear stress was the distal end of the aneurysm regardless of the diameter ratios.

Effects of Root Diameter Within Different Root Parts on Ginsenoside Composition of Yunpoong Cultivar in Panax ginseng C. A. Meyer (인삼 연풍의 근 부위별 직경이 진세노사이드 함량에 미치는 영향)

  • Li, Xiangguo;Kang, Sun-Joo;Han, Jin-Soo;Kim, Jung-Sun;Choi, Jae-Eul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.17 no.6
    • /
    • pp.452-457
    • /
    • 2009
  • This study was carried out to investigate the correlation between root diameter and ginsenoside composition of Panax ginseng C. A. Meyer cultivar Yunpoong. Dry matter ratio of main root was a little higher than that of lateral root and fine root, and that was higher by the increase of root diameter in the same root parts. Total ginsenosides composition of main and lateral roots increased by the decrease of root diameter, especially in lateral root. Similar resulted in fine root, but there was no significant difference where root diameter was below 2.5 mm. Except for ginsenoside-$Rg_1$, other ginsenosides component, PDs, PTs and total ginsenosides had highly negative correlation with the root diameter within whole root, main root+lateral root and lateral root+fine root, while $Rg_1$ had positive correlation with the root diameter.

A Study on Critical Heat Elux Characteristics in a Two-Phase Concentric-Tube Thermosyphon (2중관형 2상 열사이폰의 한계열유속 특성에 관한 연구)

  • Kim, Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1419-1426
    • /
    • 2002
  • An experimental study was made to elucidate critical heat flux(CHF) characteristics in a two-phase concentric-tube thermosyphon. The experiment was performed by using saturated water, over the experimental range of configuration: inner diameter of heated outer tube D=12mm, outer diameter of unheated inner tube do=3 to 10mm and heated tube length L=100 to 1000mm. The experiment shows that the CHF is enhanced with increase in the inner tube diameter, and that the CHF decreases beyond a certain diameter of the inner tube. There is an optimum diameter for inner tube that maximizes the CHF, for each tube length and test liquid. The CHF maximum is about two to eight times as large as that without an inner tube. For a large inner tube, the CHF characteristics is similar to that for natural convective boiling in a vertical annular tube.

The Effect of Nozzle Diameter on Heat Transfer to a Fully Developed Round Impinging Jet (완전 발달된 원형 충돌제트의 노즐 직경이 열전달에 미치는 영향)

  • Lee, Dae-Hee;Won, Se-Youl;Lee, Young-Min;Cho, Heon-No
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.519-525
    • /
    • 2000
  • The effect of nozzle diameter on the local Nusselt number distributions has been investigated for an axisymmetric turbulent jet impinging on the flat plate surface. The flow at the nozzle exit has a fully developed velocity profile. A uniform heat flux boundary condition at the plate surface was created using gold film Intrex. Liquid Crystal was used to measure the plate surface temperature. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle to surface distance (L/d) from 2 to 14, and the nozzle diameter (d) from 1.36 to 3.40 cm. The results show that the Nusselt number at and near the stagnation point increase with an increasing value of the nozzle diameter.