• 제목/요약/키워드: Incoming Wind Velocity

검색결과 16건 처리시간 0.02초

다리우스형 풍력블레이드의 설계 방법 (Design Method for the Darrieus Type Wind Turbine)

  • 이장호;두리엔
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1465-1469
    • /
    • 2009
  • Darrieus wind turbine blade is one of the vertical wind power system in which the lift of blade is used. In the calculation of wind power for the type of that, the multiple streamtubes method is known as an effective method. But it has big difference in the region of higher tip speed ratio because the incoming air velocity is used in the calculation of lift. The incoming air velocity is reduced from inlet to outlet continually by transferring energy to the wind blade. In this study, the air velocity on the blade, which is called blade velocity, is obtained with newly developed algorithm and used to determine the lift. And it is verified that applying blade velocity on the lift calculation cause the power prediction to improve dramatically in the region of higher tip speed ratio.

  • PDF

An enhanced analytical calculation model based on sectional calculation using a 3D contour map of aerodynamic damping for vortex induced vibrations of wind turbine towers

  • Dimitrios Livanos;Ika Kurniawati;Marc Seidel;Joris Daamen;Frits Wenneker;Francesca Lupi;Rudiger Hoffer
    • Wind and Structures
    • /
    • 제38권6호
    • /
    • pp.445-459
    • /
    • 2024
  • To model the aeroelasticity in vortex-induced vibrations (VIV) of slender tubular towers, this paper presents an approach where the aerodynamic damping distribution along the height of the structure is calculated not only as a function of the normalized lateral oscillation but also considering the local incoming wind velocity ratio to the critical velocity (velocity ratio). The three-dimensionality of aerodynamic damping depending on the tower's displacement and the velocity ratio has been observed in recent studies. A contour map model of aerodynamic damping is generated based on the forced vibration tests. A sectional calculation procedure based on the spectral method is developed by defining the aerodynamic damping locally at each increment of height. The proposed contour map model of aerodynamic damping and the sectional calculation procedure are validated with full-scale measurement data sets of a rotorless wind turbine tower, where good agreement between the prediction and measured values is obtained. The prediction of cross-wind response of the wind turbine tower is performed over a range of wind speeds which allows the estimation of resulting fatigue damage. The proposed model gives more realistic prediction in comparison to the approach included in current standards.

화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구 (A Study on Improvenment of Livingroom Smoke-control System using the FDS)

  • 김미선;백은선
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.26-34
    • /
    • 2017
  • 본 논문은 거실제연설비의 인접구역 상호제연방식의 성능 확인 및 향상을 위한 논문으로써 국가화재안전기준(NFSC)과 NFPA 연기제어에 관한 규정을 비교 분석하였다. 분석방법은 화재 시뮬레이션(FDS)을 통해 모델링을 실시하여, 급기량 변화, 제연경계의 폭, 화재실내 가연물 변화, 유입공기의 풍속차이를 통해 이루어졌다. 그 결과 청결층 확보를 위해 급기량을 배출량 이하로 하였을때 화재실에서의 청결층 확보에 유리한 것으로 나타났으나 급기실에서는 급기량을 배출량 이상으로 하였을때 청결층 확보에 유리한 것으로 나타났으며, 제연경계의 폭이 길어질수록 성능 확보에 유리한 것으로 나타났다. 또한 가연물의 종류에 따라 급기량과 배출량을 고려해야 하며, 공기유입구 풍속은 급기량을 감소시킴과 동시에 공기유입구 풍속을 낮게 하므로써 화재실의 청결층 확보에 유리한 것으로 나타났다.

A Statistical Approach to Examine the Impact of Various Meteorological Parameters on Pan Evaporation

  • Pandey, Swati;Kumar, Manoj;Chakraborty, Soubhik;Mahanti, N.C.
    • 응용통계연구
    • /
    • 제22권3호
    • /
    • pp.515-530
    • /
    • 2009
  • Evaporation from surface water bodies is influenced by a number of meteorological parameters. The rate of evaporation is primarily controlled by incoming solar radiation, air and water temperature and wind speed and relative humidity. In the present study, influence of weekly meteorological variables such as air temperature, relative humidity, bright sunshine hours, wind speed, wind velocity, rainfall on rate of evaporation has been examined using 35 years(1971-2005) of meteorological data. Statistical analysis was carried out employing linear regression models. The developed regression models were tested for goodness of fit, multicollinearity along with normality test and constant variance test. These regression models were subsequently validated using the observed and predicted parameter estimates with the meteorological data of the year 2005. Further these models were checked with time order sequence of residual plots to identify the trend of the scatter plot and then new standardized regression models were developed using standardized equations. The highest significant positive correlation was observed between pan evaporation and maximum air temperature. Mean air temperature and wind velocity have highly significant influence on pan evaporation whereas minimum air temperature, relative humidity and wind direction have no such significant influence.

Thrust force and base bending moment acting on a horizontal axis wind turbine with a high tip speed ratio at high yaw angles

  • Bosnar, Danijel;Kozmar, Hrvoje;Pospisil, Stanislav;Machacek, Michael
    • Wind and Structures
    • /
    • 제32권5호
    • /
    • pp.471-485
    • /
    • 2021
  • Onshore wind turbines may experience substantially different wind loads depending on their working conditions, i.e. rotation velocity of rotor blades, incoming freestream wind velocity, pitch angle of rotor blades, and yaw angle of the wind-turbine tower. In the present study, aerodynamic loads acting on a horizontal axis wind turbine were accordingly quantified for the high tip speed ratio (TSR) at high yaw angles because these conditions have previously not been adequately addressed. This was analyzed experimentally on a small-scale wind-turbine model in a boundary layer wind tunnel. The wind-tunnel simulation of the neutrally stratified atmospheric boundary layer (ABL) developing above a flat terrain was generated using the Counihan approach. The ABL was simulated to achieve the conditions of a wind-turbine model operating in similar inflow conditions to those of a prototype wind turbine situated in the lower atmosphere, which is another important aspect of the present work. The ABL and wind-turbine simulation length scale factors were the same (S=300) in order to satisfy the Jensen similarity criterion. Aerodynamic loads experienced by the wind-turbine model subjected to the ABL simulation were studied based on the high frequency force balance (HFFB) measurements. Emphasis was put on the thrust force and the bending moment because these two load components have previously proven to be dominant compared to other load components. The results indicate several important findings. The loads were substantially higher for TSR=10 compared to TSR=5.6. In these conditions, a considerable load reduction was achieved by pitching the rotor blades. For the blade pitch angle at 90°, the loads were ten times lower than the loads of the rotating wind-turbine model. For the blade pitch angle at 12°, the loads were at 50% of the rotating wind-turbine model. The loads were reduced by up to 40% through the yawing of the wind-turbine model, which was observed both for the rotating and the parked wind-turbine model.

Autorotation of square plates, with application to windborne debris

  • Martinez-Vazquez, P.;Sterling, M.;Baker, C.J.;Quinn, A.D.;Richards, P.J.
    • Wind and Structures
    • /
    • 제14권2호
    • /
    • pp.167-186
    • /
    • 2011
  • This paper presents the results of measurements relating to the aerodynamic forces on flat square plates which were allowed to rotate at different speeds about their horizontal axis, by modifying the velocity of the incoming flow. A 1 m square test-sheet and a 0.3 m square test-sheet were fitted with a number of pressure sensors in order to obtain information relating to the instantaneous pressure distribution acting on the test-sheet; a compact gyroscope to record the angular velocity during the rotational motion was also implemented. Previous work on autorotation has illustrated that the angular velocity varies with respect to the torque induced by the wind, the thickness and aspect ratio of the test-sheet, any frictional effects present at the bearings, and the vorticity generated through the interaction between the plate and the wind flow. The current paper sets out a method based on the solution of the equation of motion of a rotating plate which enables the determination of angular velocities on autorotating elements to be predicted. This approach is then used in conjunction with the experimental data in order to evaluate the damping introduced by the frictional effects at the bearings during steady autorotation.

요트세일의 풍동시험을 위한 공력 계측시스템 구축과 모형세일의 공력 계측 (A Construction of Aerodynamic Force Measurement System for Wind Tunnel Test of Yacht Sail and Aerodynamic Forces Measurement of Model Sail)

  • 김철희;최정규;김형태
    • 대한조선학회논문집
    • /
    • 제48권5호
    • /
    • pp.445-450
    • /
    • 2011
  • In order to estimate a yacht sail performance, measuring system of aerodynamic forces acting on the yacht sail is constructed and experiments of flexible model sail are carried out at the medium-size subsonic wind tunnel of Chungnam National University. Experimental results for a flexible sail are compared with experimental and numerical results of fixed shape sail. In case of a fixed shape sail, lift and drag coefficients are rarely changed at all velocity conditions. However, those of the flexible sail are decreased as the incoming velocity is increased. These are understandably resulted from shape variations due to the flexible material. Therefore aero-elastic similarity should be more carefully considered in the model test rather than other similarities.

PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구 (Improvement of Natural Ventilation in a Factory Building Using PIV Technique)

  • 강종훈;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

Maximum vortex-induced vibrations of a square prism

  • Barrero-Gil, A.;Fernandez-Arroyo, P.
    • Wind and Structures
    • /
    • 제17권1호
    • /
    • pp.107-121
    • /
    • 2013
  • This paper presents an experimental investigation concerning the peak amplitudes of oscillation of a square prism due to Vortex-Induced-Vibrations (VIV) as a function of the mass damping parameter $m^*{\zeta}$(the so called Griffin--plot); $m^*$ and ${\zeta}$ being, respectively, the non-dimensional mass and the mechanical (structural) damping ratio. With this purpose in mind, an electromagnetic actuator has been employed to provide controlled damping. During the experiments the mass--damping parameter was in the range 0.15 < $m^*{\zeta}$ < 2.4. Experiments show that there is a value of $m^*{\zeta}$ below which VIV appears combined with galloping and the prism oscillation increases monotonically with the incoming flow velocity. For $m^*{\zeta}$ >0.3 the present experiments show a well-defined VIV phenomenon and, consequently, a Griffin-plot can be defined.

Maximum Vortex-Induced Vibrations of a square prism

  • Barrero-Gil, A.;Fernandez-Arroyo, P.
    • Wind and Structures
    • /
    • 제16권4호
    • /
    • pp.341-354
    • /
    • 2013
  • This paper presents an experimental investigation concerning the peak amplitudes of oscillation of a square prism due to Vortex-Induced-Vibrations (VIV) as a function of the mass damping parameter $m^*{\zeta}$ (the so called Griffin--plot); $m^*$ and ${\zeta}$ being, respectively, the non-dimensional mass and the mechanical (structural) damping ratio. With this purpose in mind, an electromagnetic actuator has been employed to provide controlled damping. During the experiments the mass--damping parameter was in the range 0.15 < $m^*{\zeta}$ < 2.4. Experiments show that there is a value of $m^*{\zeta}$ below which VIV appears combined with galloping and the prism oscillation increases monotonically with the incoming flow velocity. For $m^*{\zeta}$ >0.3 the present experiments show a well-defined VIV phenomenon and, consequently, a Griffin-plot can be defined.