• 제목/요약/키워드: Inclination angles

검색결과 233건 처리시간 0.024초

스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구 (A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks)

  • 박기호;이기우;노승용;이석호;유성연
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

경사면에서의 분무냉각 막비등 열전달에 관한 실험적 연구 (Experimental Study on Film Boiling Heat Transfer of Spray Cooling for Inclined heat transfer Surface)

  • 김영찬
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2010
  • The film boiling heat transfer was experimentally investigated for the water sprays impacting on an inclined hot surface. Full cone spray nozzles were employed for the spray cooling experiment, and experiments were made for different inclination angles of $\theta=0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$. The experimental results show that, in the downstream region of the inclined hot surface, increasing the inclination angle increases the local heat flux slowly because of increasing the number of rebound droplets. However, the inclination angle of heat transfer surface had no remarkable effect on the local heat flux of spray cooling under the present test conditions.

Effect of Inclination Angle and Size of Heated Surface on Pool Boiling CHF

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.155-155
    • /
    • 1999
  • Pool boiling critical heat flux (CHF) have been investigated using plate type test sections with different widths (3 cm & 4 cm) and lengths (10 cm, IS cm & 20 cm) under various incli- nation angles. As the inclination angle increases from $0^{\circ}$ (horizontally facing downward plate) to $30^{\circ}$, CHF sharply increases. After that angle, CHF gradually increases with the increase of the inclination angle. There must be a transition angle between $0^{\circ}$ and $30^{\circ}$, at which the CHF increase rate remarkably changes. According to the comparison of present and previous ex- periments, the transition angle may be affected by heater size and increase with the increase of heater size. The size effect of heated surface on CHF is noticeable in the L15 & L20 series and W4 series; however, it seems to be difficult to find the size effect in L10 series and W3 series.

  • PDF

Inclination angle influence on noise of cavitating marine propeller

  • Bal, Sakir
    • Ocean Systems Engineering
    • /
    • 제10권1호
    • /
    • pp.49-65
    • /
    • 2020
  • In this study, the effects of inclined shaft angle on the hydro-acoustic performance of cavitating marine propellers are investigated by a numerical method developed before and Brown's empirical formula. The cavitating blades are represented by source and vortex elements. The cavity characteristics of the blades such as cavitation form, cavity volume, cavity length etc., are computed at a given cavitation number and at a set advance coefficient. A lifting surface method is applied for these calculations. The numerical lifting surface method is validated with experimental results of DTMB 4119 model benchmark propeller. After calculation of hydrodynamic characteristics of the cavitating propeller, noise spectrum and overall sound pressure level (OASPL) are computed by Brown's equation. This empirical equation is also validated with another numerical results found in the literature. The effects of inclined shaft angle on thrust coefficient, torque coefficient, efficiency and OASPL values are examined by a parametric study. By modifying the inclination angles of propeller, the thrust, torque, efficiency and OASPL are computed and compared with each other. The influence of the inclined shaft angle on cavity patterns on the blades are also discussed.

서 있는 자세와 앉은 자세에서 두부자세의 변화 (Changes of Head Posture in Standing and Sitting Posture)

  • Sang-Chan Lee;Kyung-Soo Han;Myung-Seok Seo
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.305-315
    • /
    • 1996
  • This study was performed to investigate the changes of head posture according to natural standing or sitting posture. Twenty seven healthy dental students without any signs and symptoms of temporomandibular disorders participated in this study. Cervical resting posture (CRP) of the head in sagittal plane was measured by Cervical-Range-of-Motion $^\textregistered$(CROM, U.S.A.) and lateral cephalograph was taken in natural posture. The items related to angle in cephalograph were the angles of cranial and cervical inclination to true vertical line(VER/NSL, VER/AML), the angles of cervical inclination to nasion-sella line(CVT/NSL, OPT/NSL), the angles of comical inclination to horizontal line(CVT/HOR, OPT/HOR), the angle of cervical lordosis(CVT/OPT). The items related to line measurement were the distance from subocciput to Cl(Dl), Cl to C2(D2), C2 to C3(D3), C3 to C4(D4), the upper(PNS to posterior pharyngeal wall) and the lower(tongue base to posterior pharyngeal wall) pharyngeal space, the distance from nation to mention(Na-Me), and the radius of comical curvature from the first comical vertebra(Cl ) to the fifth cervical vertebra(C5). The data were analyzed with SAS/STAT program. The obtained results were as follows : 1. Most items related to angular measurement showed significant difference between in standing and sitting posture. The angles of CRP, CVT/NSL, OPT/NSL, CVT/HOR, OPT/HOR, and CVT/OPT were high in sitting posture, but the angles of VER/NSL, VER/NSL were low in sitting posture. 2. In vertebral distance, only the distance between C3 and C4 was differed by the posture, which decreased in sitting posture. In sitting posture, the distance from nasion to menton(Na-Me) was longer, but the radius was shorter than in standing posture. 3. Correlationship in angular measurements was almost same in both postures. Ceervical resting posture(CRP) was correlated with VER/NSL, VER\ulcornerNSL was correlated with CRP, CVT/NSL, and OPT/NSL, VER/AML was correlated with CVT/HOR, OPT/HOR, CVT/OPT, and the angle of cervical lordosis(CVT/OPT) was correlated with the radius. 4. Correlationship in linear measurement was observed only in among D3, D4, and radius. And the Na-Me was not correlated with any other items. From this results, The author concluded that the head posture in sitting was mote backward extended than in standing.

  • PDF

임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향 (THREE-DIMENTIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION FOR DIFFERENT IMPLANT THREAD SLOPE)

  • 서영훈;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.482-491
    • /
    • 2007
  • Statement of problem: The screws of dental implant, having various thread types, can be categorized into different classes by their geometrical form, and each type transmits dissimilar amount and form of stress to alveolar bone. Purpose: The purpose of this study was to find an inclination angle of the screw thread that is favorable in distributing the stresses to alveolar bone. Material and methods: In this study, We used three dimensional finite element analysis with modeling having three types of thread inclination angles and fixed pitch-0.8 mm (single thread type with $3.8^{\circ}$ inclination, double thread type with $7.7^{\circ}$ inclination, triple thread type with $11.5^{\circ}$ inclination). Results: The results obtained from this study were as follows; 1. When the number of thread increased, the amount of Von-Mises stress was reduced since the generated stress was effectively distributed. 2. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants when comparing the magnitude of the maximum principal stress double thread had least amount of stress. This shows that the double thread screw gave best result. Conclusion: In conclusion, double, and triple thread screws were found to be more effective on distribution of the stress than the single thread screws. But, increasing in the thread inclination angle such as triple thread screw relate on the magnitude of the maximum principal stress affecting on the alveolar bone can become problematic. Thus, effective combination of thread number and thread inclination angle can help prolonging the longevity of implant.

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

밑면에서 부분가열을 받는 경사4각형 밀폐공간내의 자연대류 열전달 및 유동특성 (Natural Convective Heat Transfer and Flow Characteristics in Inclined Rectangular Enclosures with Localized Heating from Below)

  • 김상호;정인기;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제13권3호
    • /
    • pp.148-156
    • /
    • 1984
  • The effect of inclination on the steady, two-dimensional, laminar natural convection in rectangular enclosures with localized heating from below has been investigated numerically. The enclosure was uniformly heated with a partial heat source at the center of the bottom wall and cooled from the upper wall while the other walls were insulated. The governing equations were solved numerically by using the ADI finite difference method with the SOR method. The computations were carrid out with air, Pr =0.733, in the Grashof number range, $1\times10^4\~3\times10^4$, for the inclination of the enclosures was varied from $0^{\circ}\;to\;90^{\circ}$. The effects of Grashof number and aspect ratio on the inclination for the transition of the flow pattern in enclosures were determined. From the results, it was found that the transition angles of the flow in the enclosures were greater in localized heating than in uniform heating from below, and that the inclination was to strongly effect on the heat transfer and the flow pattern within the enclosure.

  • PDF

히트펌프 건조기용 PF 열교환기 성능 및 해석 연구 (Study on Performance and Analysis of PF Heat Exchanger for Heat Pump Dryer)

  • 김기영;이석현;권영철;전종균;박삼진
    • 한국산학기술학회논문지
    • /
    • 제14권4호
    • /
    • pp.1576-1581
    • /
    • 2013
  • 본 연구에서는 히트펌프 건조기용에 적용될 PF 열교환기에 대하여 연구되었다. PF 열교환기의 설치 경사각($0^{\circ}$, $30^{\circ}$, $60^{\circ}$)에 따른 3종 PF 열교환기의 능력과 제습량을 측정하였다. 실험은 건구온도 $60^{\circ}C$, 상대습도 70%, 풍속 0.5m/s에서 진행되었다. 실험결과 경사각이 증가할수록 열교환기의 성능이 우수하였으며, PF3가 능력과 제습량에서 가장 우수하였다. 그러나 경사각이 $60^{\circ}$에서는 능력과 제습량이 크게 감소하였다. 실험값을 예측하기 위해 PF 열교환기의 능력과 제습량을 예측할 수 있는 계산프로그램을 개발하였다. PF 열교환기 3종에 대한 실험값과 계산값은 능력의 경우에 최대 2% 이내를 제습량의 경우에 최대 3% 이내에서 만족한 결과를 보여주었다.