• 제목/요약/키워드: Inclination Angle

Search Result 756, Processing Time 0.032 seconds

Changes of Head Posture in Standing and Sitting Posture (서 있는 자세와 앉은 자세에서 두부자세의 변화)

  • Sang-Chan Lee;Kyung-Soo Han;Myung-Seok Seo
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.305-315
    • /
    • 1996
  • This study was performed to investigate the changes of head posture according to natural standing or sitting posture. Twenty seven healthy dental students without any signs and symptoms of temporomandibular disorders participated in this study. Cervical resting posture (CRP) of the head in sagittal plane was measured by Cervical-Range-of-Motion $^\textregistered$(CROM, U.S.A.) and lateral cephalograph was taken in natural posture. The items related to angle in cephalograph were the angles of cranial and cervical inclination to true vertical line(VER/NSL, VER/AML), the angles of cervical inclination to nasion-sella line(CVT/NSL, OPT/NSL), the angles of comical inclination to horizontal line(CVT/HOR, OPT/HOR), the angle of cervical lordosis(CVT/OPT). The items related to line measurement were the distance from subocciput to Cl(Dl), Cl to C2(D2), C2 to C3(D3), C3 to C4(D4), the upper(PNS to posterior pharyngeal wall) and the lower(tongue base to posterior pharyngeal wall) pharyngeal space, the distance from nation to mention(Na-Me), and the radius of comical curvature from the first comical vertebra(Cl ) to the fifth cervical vertebra(C5). The data were analyzed with SAS/STAT program. The obtained results were as follows : 1. Most items related to angular measurement showed significant difference between in standing and sitting posture. The angles of CRP, CVT/NSL, OPT/NSL, CVT/HOR, OPT/HOR, and CVT/OPT were high in sitting posture, but the angles of VER/NSL, VER/NSL were low in sitting posture. 2. In vertebral distance, only the distance between C3 and C4 was differed by the posture, which decreased in sitting posture. In sitting posture, the distance from nasion to menton(Na-Me) was longer, but the radius was shorter than in standing posture. 3. Correlationship in angular measurements was almost same in both postures. Ceervical resting posture(CRP) was correlated with VER/NSL, VER\ulcornerNSL was correlated with CRP, CVT/NSL, and OPT/NSL, VER/AML was correlated with CVT/HOR, OPT/HOR, CVT/OPT, and the angle of cervical lordosis(CVT/OPT) was correlated with the radius. 4. Correlationship in linear measurement was observed only in among D3, D4, and radius. And the Na-Me was not correlated with any other items. From this results, The author concluded that the head posture in sitting was mote backward extended than in standing.

  • PDF

A Study on the Performance of Boiling Beat Transfer of Inclined Thermosyphon Heat Exchangers with Internal Grooves (경사 열사이폰 열교환기의 비등열전달 성능에 관한 연구)

  • Cho, Dong-Hyun;Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.202-209
    • /
    • 2005
  • This study concerns the performance of boiling heat transfer in inclined thermosyphons with internal grooves. A study was carried out with the performance of the heat transfer of the inclined thermosyphon having 60 internal grooves in which boiling and condensation occur. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphon is also tested for comparison. Distilled water, methanol and ethanol have been used as the working fluid. The inclination angle, three working fluids, heat flux and the boiling heat transfer coefficient at the evaporator zone are estimated from the experimental results. The experimental results have been assessed and compared with existing correlations. Imura's and Kusuda's correlation for boiling showed in good agreement with experimental results within ${\pm}20%$ in plain thermosyphon. The high heat transfer coefficient was found between $25^{\circ}$ and $30^{\circ}$ of inclination angle for water and between $20^{\circ}$ and $25^{\circ}$ for methanol and ethanol. The relatively high rates of heat transfer have been achieved in the thermosyphon with internal micro grooves.

  • PDF

Effect of Joint Cohesive Strength on the Earth Pressure against the Support System in a Jointed Rock Mass (절리형성 암반지층 굴착벽체 작용토압에 대한 절리 점착강도의 영향)

  • Son, Moorak;Solomon, Adedokun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.7
    • /
    • pp.41-53
    • /
    • 2014
  • This study examined the magnitude and distribution of the earth pressure on the support system in a jointed rock mass by considering different joint shear strength, rock type, and joint inclination angle. The study particularly focused on the effect of joint cohesive strength for a certain condition. Based on a physical model test (Son and Park, 2014), extended parametric studies were conducted considering rock-structure interactions based on the discrete element method, which can consider the rock and joint characteristics of rock mass. The results showed the earth pressure was strongly affected by the joint cohesive strength as well as the rock type and joint inclination angle. The study indicated that the effect of joint cohesive strength was particularly significant when a rock mass was under the condition of joint sliding. This paper investigates the magnitude of joint cohesive strength to prevent a joint sliding for each different condition. The test results were also compared with Peck's earth pressure, which has been frequently used for soil ground. The comparison indicated that the earth pressure in a jointed rock mass can be significantly different from that in soil ground. This study is expected to provide a better understanding of the earth pressure on the support system in a jointed rock mass.

An Analytical Study on Determination of Dimensions of Drystone Masonry Retaining Walls (석축의 단면결정에 대한 해석적 연구)

  • Seung-Hyun Lee
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.60-68
    • /
    • 2023
  • Purpose: In order to find out stability condition which governs design of drystone masonry retaining walls and changing patterns of installed width of blocks of the wall for each stability conditions, typical wall was assumed and designed. Method: For the purpose of this study, 10 m high drystone masonry retaining wall with general block size and soil properties were considered and dimensions of the wall were determined by applying stability conditions of sliding and overturning and the design results were compared with each other. Result: According to the design results, installed width of blocks determined by considering stability of sliding were greatly less than those determined by considering stability of overturning and these differences were not decreased noticeably even though same values of factors of safety for sliding and overturning were applied. Between the two methods of determining the installed width of blocks, it could be seen that the method of considering failure wedge of lower part of overturning parts of the wall governed the design instead of considering horizontal base of overturning parts of the wall. Conclusion: In case of considering failure wedge of lower part of overturning parts of the wall, it could be seen that the installed width of blocks increased as the inclination angle of failure wedge increased. In case of considering overturning at the lower part of the wall with certain assumed inclination angle of failure wedge, it could be seen that installed width of blocks decreased as the inclination angle of failure wedge decreased by geometric restrictions of the wall.

A Self-gravitational Acupressure Corrects the Standing Posture in the Sagittal Plane: A Retrospective Study (자가 중력 지압의 시상면 기립 자세 교정 효과: 후향적 관찰 연구)

  • Sung Kwon Park;Geum Na Hong;Min Joo Choi
    • Journal of Naturopathy
    • /
    • v.13 no.1
    • /
    • pp.51-61
    • /
    • 2024
  • Background: Manual acupressures in the correction and recovery of spinal deformities are known to be effective. However, they rely on therapists' skill and often require a long treatment time. The shortcomings of the manual therapy are anticipated to be effectively mitigated through self-gravitational acupressures (SGA) which stimulate multiple acupoints simultaneously with acupressure tools. Objective: The study aims to verify the effect of SGA for the correction of sagittal standing posture. Methods: A retrospective analysis was conducted on the postural improvements of the 93 subjects who underwent the SGA intervention, leveraging self-gravity for stimulating neck, back, pelvis, and calf areas both overall and sequentially using a set of acupressure tools equipped with multiple acupressing rods. Degree of posture abnormality was assessed before and after the SGA intervention using the photographic images of the subjects' sagittal standing postures, based on the angles of inclination of the upper body (from external auditory meatus to pelvis) and the lower body (from pelvis to malleolus) from the gravitational line passing through the hip joint. Results: After the SGA intervention, the upper body inclination angle was observed to decrease from an average of 3.2° to 1.6° (50.0% reduction, p<.001), and the lower body inclination angle decreased from an average of 3.5° to 3.2° (8.6% reduction, p<.01). Conclusion: The observed results underpin that SGA is effective for the correction of postural deformities. For the clinical application of SGA, prospective research is needed to optimize SGA protocol and acupressing tools and to validate long-term clinical efficacy.

A ROENTGENOCEPHALOMETRIC STUDY ON MANDIBULAR PROGNATHISM (하악(下顎) 전돌증(前突症)에 관(關)한 방사선(放射線) 두부계측학적(頭部計測學的) 연구(硏究))

  • Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.9 no.1
    • /
    • pp.85-98
    • /
    • 1979
  • This investigation was designed to compare the craniofacial and dental morphology of class III malocclusion with that of normal occlusin in children, and to determine the incidence of various class III craniofacial skeletal patterns. The material selected for this study consisted in standard lateral cephalograms of eighty two Korean children, forty one boys and forty one girls, aged 10 through 12 years, having class III malocclusion, and forty two Korean children, twenty boys and twenty two girls, with normal occlusion in the same age. Using the tracings of the standard lateral cephalograms, various angular and linear measurements were recorded, tabulated and statistically analyzed, and then the class III craniofacial skeletal morphology was divided into various patterns by the degree of SNA and SNB, which respectively were below, within or beyond the normal range of those of normal occlusion. The following characteristics of the craniofacial and dental morphology of class III malocclusion were observed. 1. The cranial base length of class III malocclusion was smaller than that of normal occlusion, and the small saddle angle was a characteristic figure of class III malocclucion. 2. Maxillary length of class III malocclusion was smaller than that of normal occlusion, and point A was retropositioned relative to cranial base but not PNS in class III malocclusion. Maxillary base inclination was not significantly different between the two, but occlusal plane to palatal plane was small in class III malocciusion. 3. The mandibular body length shown no difference between the two, but the mandibular body positioned anteriorly relative to cranial base in class III malocclusion. Ramus height, gonial angle, and mandibular effective length were large in class III malocclusion. Mandibular plane angle and joint angle had no difference between the two, and occlusal plane to mandibular plane angle was large in class III malocclusion. 4. Maxillary incisor inclination was not significantly different between class III malocclusion and normal occlusion, but mandibular incisors positioned and inclined lingually and consequently interincisal angle was large in class III malocclusion. 5. Class III malocclusion was divided into six categories of craniofacial skeletal pattern. The most common class III pattern was found to be one in which the maxilla was within the normal range of prognathism while the mandible extended beyond this range. The pattern in which the maxilla was below the normal range of prognathism while the mandible was within this range was approximately one fifth of the class III sample.

  • PDF

Accuracy Evaluation of Non-prism Total Station for Topographic Surveying (지형측량을 위한 무 프리즘 토털스테이션 정확도 평가)

  • Seo, Dong-Ju
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.5
    • /
    • pp.433-441
    • /
    • 2006
  • With a development of electrical technology in recent, it is possible to measure distance without direct contact to object using laser which launched at instrument and reflect from object. Furthermore, the advent of non prism total station brought the increment of application in many fields including not only road, airport, and harbors but also measurement and monitoring of structural displacement in construction fields. In this study, therefore, to evaluate accuracy of non prism total station, accuracy was analyzed by measuring certain distance which classified by both certain materials and angle of reflection. By this method, the derived values were applied to topographical survey for the efficient applicability. According to a study, result value of non prism total station was satisfBctory regardless of material when the angle of reflection was 90 degrees. RMSE increased when the angle of reflection are gradually increased to acute angle. In result of regression analysis using certain distance which classified by both materials and angles of reflection, there is relationship between distance and angle of reflection, but material has no relevance to the result value. When carrying out general topographical survey, proper application of non prism total station will go far conducting safe and prompt survey at the dangerous site such a road which have lots of traffic flow and rock joint which have high angles of inclination.

The 3-D Motion Analysis of Kinematic Variety on Lower Extremity during Ramp Ascent at Different Inclinations (정상인의 오름 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석)

  • Han, Jin-Tae;Lee, Jong-Dae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.633-650
    • /
    • 2005
  • The aim of this study was to investigate the kinematics of young adults during ascent ramp climbing at different inclinations. Twenty-three subjects ascended a four step at four different inclinations(level, $8^{\circ},\;16^{\circ},\;24^{\circ}$). The 3-D kinematics was analysed by a camera-based falcon system. Groups difference was tested with one -way ANOVA and SNK test. The different kinematic patterns of ramp ascent were analysed and compared to level walking patterns. The kinematics of ramp walking could be clearly distinguished from the kinematics of level walking. In sagittal plane, Ankle joint was more dorsiflexed at initial contact and Max. dorsiflex. during stance phase with $16^{\circ},\;24^{\circ}$ inclination and more plantarflexed at toe off and Max. plantarflex. during swing phase with $24^{\circ}$(p<.001). Knee joint was more flexed at initial contact with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was more flexed at initial contact and Max. flex. during swing phase with $16^{\circ},\;24^{\circ}$ inclination and at toe off with $24^{\circ}$(p<.001) and was more extended at Max. ext. during stance phase with $24^{\circ}$(p<.05). In frontal plane, ankle joint was more everted at Max. eversion. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Knee joint was more increased at Max. varus. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was not differentiated with different inclinations. In horizontal plane, all joints were not differentiated with different inclinations. Conclusionally, In ascent ramp walking, the different gait pattern generally occurred at over $16^{\circ}$ on the ascending ramp in sagittal and frontal plane. These results suggest that there is a certain inclination angle or angular range where subjects do switch between a level walking and a ascent ramp walking gait pattern. This shows their motor control strategy between level and ascent ramp walking. Further studies are necessary to confirm and detect the ascent ramp gait patterns.

  • PDF

Evaluation of the Elderly Gait Stability Using the Center of Mass and Center of Pressure Inclination Angles (전, 후방 기울기각을 이용한 노인의 보행안정성 평가)

  • Yoon, Suk-Hoon;Kim, Tae-Sam;Lee, Jae-Hun;Ryu, Ji-Seon;Kwon, Young-Hoo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.99-106
    • /
    • 2007
  • The gait instability in the elderly has been associated with age-related deterioration in physical strength and reducing the potential for elderly falls requires regular exercise. In 2005, National Center for Injury Prevention and Control(NCIPC) reported that most elderly falls occur during activities in daily living(ADL). To better reveal biomechanic mechanisms underlying age-related degeneration in gait stability, and to enhance the assessment of falls risk, an accurate quantification of a person's balance maintenance during locomotion is needed. Instantaneous orientation of the line connecting COP and COM can characterize whole body position with respect to the supporting foot during gait and the angle between this line and the vertical line passing through the COP known as a good assessment to detect the elderly gait instability. Therefore the purpose of this study was to investigate a 6-month walking exercise effects in reducing elderly fall risk factors by using COP-COM inclination angles. Twenty-two community-dwelling elderly participated this study. The participants performed a walking exercise(3 times/week, 1 hour/visit) for 6 months. Laboratory kinematics during walking was assessed at months 0, 3 and 6. Significant increased in gait velocity was found among periods(p=.011, $1.25{\pm}.03$, $1.32{\pm}.03$, and $1.39{\pm}.04\;m/s$ in 0-, 3-, and 6-month, respectively). Also, significant differences in anterior and posteriror inclination angles were found among the periods(p<.05; posterior inclination angles: $12.8{\pm}2.2$, $11.0{\pm}2.9$, & $10.9{\pm}1.9$; anterior inclination angles: $13.7{\pm}1.7$, $14.6{\pm}3.2$, & $1.46{\pm}.21$ in 0month, 3month, & 6month, respectively). These findings provide evidence of significant reduced fall risk factors of community-living older adults associated with a systematic walking program.

Reliability and validity of rasterstereography measurement for spinal alignment in healthy subjects

  • Yi, Yoon-Sil;Yoo, Seul-Ki;Lee, Da-Gam;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • Objective: The Back Mapper is one type of Rasterstereography and it can be used in the clinic without radiation exposure. The purpose of our study was to prove the reliability and validity of the Back Mapper and to compare it with the Spinal Mouse, which is an assessment tool for spinal curvatures using a wheeled mouse, and the Cobb angle by X-ray. Design: Cross-sectional study. Methods: Twenty healthy adults participated in the test to investigate for the inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with assessment devices for scoliosis such as the Back Mapper, Spinal Mouse and Cobb's angle. Data was analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement for reliability and correlation analysis for validity. Results: Intra-rater reliability of the Back Mapper was good (Cronbach's ${\alpha}$=0.821-0.984, ICC=0.696-0.969) except for assessing the lordotic angle. Inter-rater reliability was good (Cronbach's ${\alpha}$=0.870-0.958, ICC=0.770-0.919) in assessment for trunk imbalance, rotation of scapulae, thoracic angle, lumbar angle, and kyphotic angle. The kyphotic angle in the Spinal Mouse had a significant correlation icompared with the Back Mapper (r=0.510, p<0.05), and the Cobb's angle from an X-ray had a significant correlation with trunk inclination (r=0.532, p<0.05). Conclusions: These findings provide good intra-reliability of the Back Mapper in healthy subjects, but the Back Mapper requires more experienced practice to have good inter-reliability. Also, the variables of the Back Mapper does not seem as appropriate compared with the Cobb angle by X-ray.