Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

Survey of Under-Reporting Rate and Related Factors after Blood and Body Fluid Exposure among Hospital Employees (병원직원의 환자 혈액 및 체액 노출 후 미보고 및 관련 요인)

  • Kim, Og-Son;Choi, Jeong-Sil;Jeong, Jae-Sim;Park, Eun-Suk;Yoon, Sung-Won;Jung, Sun-Young;Jin, Hye-Young;Kim, Kyeong-Mi
    • Korean Journal of Adult Nursing
    • /
    • v.22 no.5
    • /
    • pp.466-476
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the under-reporting rate and related factors after blood and body fluid (BBF) exposure among hospital employees. Methods: Fifteen hundred l employees were conveniently sampled from ten university and acute care hospitals. The survey questionnaire consisted of 37 items. Data were collected from September 10 to November 30, 2008. Results: The survey response rate was 88.7%. The 47.9% (638/1,331) of hospital employees were exposed to BBF and the mean number of exposure was $4.7{\pm}5.942$ within the previous year. Under-reporting rate after BBF exposure was 69.4% (443/638). By multi-variate logistic regression analysis, the exposure number, exposure type, infectious disease and hospital were independently related to the under-reporting of BBF among hospital employees. Conclusion: The under-reporting rate after being exposed to blood and body fluids was relatively high. To address this problem, educational programs are needed to decrease the under-reporting rate for healthcare workers. Further, it might be helpful if other factors related to under-reporting be investigated in future studies.

Type-Specific Incidence and Persistence of HPV Infection among Young Women: A Prospective Study in North India

  • Datta, Palika;Bhatla, Neerja;Pandey, R.M.;Dar, Lalit;Patro, A. Rajkumar;Vasisht, Shachi;Kriplani, Alka;Singh, Neeta
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.1019-1024
    • /
    • 2012
  • Background: Infections with human papillomavirus (HPV) are highly prevalent among sexually active young women in India. However, not much is known about the incidence of type-specific human papillomavirus (HPV) infections and their patterns of persistence, especially in the Indian context. Objective: The objective of this study was to evaluate the rate of acquisition and persistence of HPV types in young women. Methods: Women residing in an urban slum in Delhi (n=1300) were followed for 24 months at 6 monthly intervals. Exfoliated cervical cells collected at each visit were tested for the presence of HPV DNA. Genotyping was performed using the reverse line blot assay. Results: The incidence rate for any HPV type was calculated to be 5 per 1000 women-months. Among high risk HPV types, HPV16 had the highest incidence rate followed by HPV59, HPV52 and HPV18, i.e., 3.0, 0.58, 0.41 and 0.35 women per 1000 women-months respectively. The persistence rate was higher for high-risk than low-risk HPV types. Among low-risk types, HPV42, HPV62, HPV84 and HPV89 were found to persist. Whereas almost all high risk types showed persistence, the highest rate was found in women with HPV types 16, 45, 67, 31, 51 and 59. The persistence rate for HPV16 infection was 45 per 1000 women-months. Conclusion: Incident HPV infections and high risk HPV type-specific persistence were found to be high in our study population of young married women. Understanding the patterns of HPV infection may help plan appropriate strategies for prevention programs including vaccination and screening.

Statistical Analysis on Application of External Solar Shading Devices (외부 차양장치의 적용실태에 관한 통계적 분석)

  • Kim, Hyo-Jung;Lee, Chul-Sung;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.65-71
    • /
    • 2016
  • Purpose : The solar shading device carries out roles in a reduction of the cooling load and an improvement of the thermal comfort of occupants by adjusting incident solar radiation. In addition, The shading device enhances the visual sensation comfort by controlling the optical properties. In order to improve building performance and comfort of occupancy, interests in application of the shading devices are getting increasing. This study investigated the application and effectiveness of the external shading device design using statistical analysis. The outcome of this paper could be utilized for the realization of status quo and for an estimation of effectiveness of the shading device Method : The period of data gathering was between 2003 and 2014 and total 459 cases of practical building project were investigated. Firstly, this study defined qualification of the shading devices; the shading device should have minimum protruding lengths of 150mm to outside and have the function of shading control. This paper investigated application rate of the shading device in real project, regional rate of application, annual change of application, materials and types. Result : The statistical analysis showed that the application rate of shading devices was 25.7% in total 459 building design projects. The application rate in central and southern region was 25.3% and 27.0% respectively. Meanwhile, Jeju region showed 22.2%, which was the lowest rate although this area needs more shading devices. The application number of the shading device was the smallest in 2007, but the rate gradually increased after that. The applications was the largest in 2014 due to growing interest of the shading devices in the building.

Heat Transfer in Radiatively Participating Gas-Particle Cavity Flows (輻射가 關與하는 氣體-固體粒子 캐비티 流動에서의 熱傳達)

  • 이종욱;이준식;이택식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.551-560
    • /
    • 1988
  • Gas-particle two phase flow and heat transfer in a cavity receiving thermal radiation through selectively transparent walls have been analyzed by a finite difference method. Particles injected from the upper hole of the cavity are accelerated downward by gravity and exit through the lower hole while they absorb, emit and scatter the incident thermal radiation. Gas phase is heated through convection heat transfer from particles, and consequently buoyancy induced flow field is formed. Two-equation model with two-way coupling is adopted and interaction terms are treated as sources by PSI-Cell method. For the particulate phase, Lagrangian method is employed to describe velocities and temperatures of particles. As thermal radiation is incident upon horizontally, radiative heat transfer in the vertical direction is assumed negligible and two-flux model is used for the solution of radiative heat flus. Gas phase velocity and temperature distributions, and particle trajectories, velocities and temperatures are presented. The effects of particle inlet condition, particle size, injection velocity and particle mass rate are mainly investigated.

An Experimental Study on the Stability of Rubble Mound Structures by Wave Directionality (사석방파제의 안정성에 미치는 방향성효과에 관한 실험적 연구)

  • 손병규;류청로
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.2
    • /
    • pp.139-148
    • /
    • 2001
  • Phenomena induced by waves, such as overtopping, sediment transport, vibration/fluctuation and destruction of structures are highly influenced by the directionality of wave propagation. These phenomena are often dominated by non-linearity, and so hydraulic model experiments are widely adopted for stability analysis rather than numerical modeling, Thus, stability ofrubblc mound breakwaters(RMB) due to wavc directionality was experimentally investigated in this study. The incident wave angle $30^{\circ}$ was found more risky on the damage rate of RMB under directional regular waves, and the incident wave angle $40^{\circ}$ was found relatively risky under directional irregular waves. These results clarified the wave directionality effect on the stability ofRMB, These facts were found correspondent to the occurrence of the peak between $20^{\circ}$-$40^{\circ}$ with the directional frequency distribution of lIlO maximum water particle velocity.

  • PDF

A Basic Study on Efficient Acrylic Plate Light Transmission Road Machining (효율적인 아크릴판 광전송로 가공에 관한 기초 연구)

  • Han, Su-Won;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • This paper proposes a method to process the shape of an optical transmission road and attempts to determine the most suitable single processing method for an acrylic plate optical transmission road. In addition, by manufacturing an automatic pattern processing device to generate certain shapes on the acrylic plate at regular intervals, and measuring the illuminance of the patterned acrylic plate optical transmission road, the measured illuminance was confirmed to fall under the KS illuminance values presented in Table 1. In conclusion, when an incident light of approximately 20,000 lx is applied, the transmission illumination is approximately 200 lx, which represents a transmission rate of approximately 1% for incident light and corresponds to the KS illumination criterion F. Additionally, the right-angle triangular pyramid base size (A) processed at a temperature of 350 ℃ for one second was 2 mm, exhibiting the largest transmission illumination of 280 lx. When the transparent acrylic plate was set to a constant size of 1.6 mm at the bottom of the right-angle triangular pyramid, the fastest response occurred at a processing tip temperature of 350 ℃ (0.04 s). On the other hand, it took 10 s to process the size of the bottom of the right-angled triangular pyramid at a temperature of 200 ℃ to 1.6 mm, and it was confirmed that the optical transmission efficiency was significantly reduced because of the burr that occurred at this time.

Suggestions for Setting on Period of Epidemic Waves in COVID-19 Epidemic of South Korea (한국 코로나19 유행기에 대한 제안)

  • Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.2
    • /
    • pp.61-66
    • /
    • 2022
  • Objectives: In the epidemiology of communicable diseases, the term epidemic period, also referred to as "wave" is often used in the general and academic milieu. A wave refers to a natural pattern of increase in the number of sick individuals, a defined peak, and then a decline in the number of cases. It implies a pattern of peaks and valleys after a particular peak is taken. The idea of epidemic waves is a useful tool for predicting the course as well as helping to accurately describe an epidemic. However, in many domestic and foreign news as well as in various research results in Korea, most of the reports either had no standard, were inaccurate, had a questionable classification of the period of the epidemic, or the basis for classification of a given wave was not presented. Methods: The author reviewed and organized related literature with epidemic wave. The author made several suggestions of an epidemic wave as follows. Results: To start with, it should be based on the number of incident cases in consideration of the size of the outbreak, then the period from the bottom to the peak and then reaching the next bottom; also, the period over a certain scale based on the number of incident cases; and the period according to the change in the major infection type (mutation-dominant species). In addition, according to the period of change in the vaccination rate (formation of herd immunity), as well as the content and duration of the intervention, that is, classification according to the applied quarantine stage. Furthermore, the classification of epidemic periods by the time-dependent reproduction number or time-varying reproduction number (Rt), and lastly the application of mathematical methodology. Conclusions: Therefore, classifying the epidemic period into generally known and accepted time frames is considered to be a very important task for future research analysis and development of intervention strategies.

Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness (목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성)

  • Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.67-72
    • /
    • 2015
  • A series of fire tests was conducted to examine the fire characteristics of flaming and smoldering combustion of engineered wood products, which have been widely used for furniture and finishing materials in buildings. The engineered wood products of MDF, plywood, and chipboard were ignited by a radiant cone heater with incident heat flux of $50kW/m^2$. During the fire test, key parameters representing the fire characteristics such as the heat release rate, yield rate of combustion product, and effective heat of combustion were quantified in terms of thickness. The tests show two peak points of HRRPUA due to lateral fire propagation in the initial stage, followed by later fire penetration through the specimen thickness. The mass loss rate of flaming combustion was 5 times higher than that of smoldering combustion, while the CO yield rate of smoldering combustion was 10 times higher than that of flaming combustion. This study can contribute to the understanding of fire behavior of wood combustibles and provide useful data for fire analysis.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF