• Title/Summary/Keyword: Incident Detection

Search Result 235, Processing Time 0.027 seconds

GIS Application for 1-1-9 Caller Location Information System (GIS를 이용한 신고자 위치표시 시스템 개발)

  • Hahm, Chang-Hahk;Jeong, Jae-Hu;Ryu, Joong-Hi;Kim, Eung-Nam
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.1 s.15
    • /
    • pp.97-103
    • /
    • 2000
  • The main purpose of 1-1-9 Caller Location Information System is to identify and display the precise location of emergency incidents such as natural or man - made fires, medical emergencies and accidents. The state - of- the - art technologies such as Am (Automatic Number Identification), GIS(Geographical Information System) and GPS (Global Positioning System) were applied and integrated in the system for efficient and effective location identification. It displays a radius of 25M, 50M and 100M on the map after location identification. The system can also provide the shortest path to an incident location from a fire station or a fire engine. In case of a fire breakout in or near a building, the attribute information of the building, called a building attribute card, is displayed along with the map location. The system then matches the information with the fire situation and sends an alert to a responsible fire station by phone or fax in order to help promptly react to the problem. An attribute card includes the critical information of a premise such as building's location, number of stories, floor plans, capacity, construction history, indoor fire detection and Prevention facilities, etc.

  • PDF

Selecting QA Items & Guidelines for Hospital Safety Management (병원내 안전관리 향상을 위한 항목 및 지침 선정)

  • Park, Jee-Won;Kim, Yong-Soon;Jin, Hye-Young
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.78-93
    • /
    • 1996
  • Background : The goal of this study was to establish the QA items and guidelines for preventing and improving of safety management. Therefore we investigated the nurses' recognition and knowledge of the safety and risk procedures and policies, and the agreement between the nurses beliefs on the degree of importance of those procedures and policies, with actual implementation in hospitals. Method : The subjects of this study were 201 nurses who participated in a program called continuing education for nurses, which held in December, 1993. Result: The results of this study were as follows: 1. Among 18 types of hospital risks, the items that scored highest or the need of closer attention in safety management was the needle stick, medication errors, falling, and bed sores. 2. In most questions of the 18 incidences, the nurses showed that the estimated result would have positive signs except for hospital infections, burns, and bed sores. 3. Even though the survey shows that incidences and types of occurences varies according to the person's age and the time of incident, they mostly occur between midnight to 6AM. Falls and bed sores can be seen more in the elderly. Medications errors, hospital infections and burns are frequently found between the ages of one through twenty. 4. There was a higher mean score for recognizing the importance of those items than the importance of implementing them. Conclusion : In summary, nurses did perceive the need of safety management but the hospital policy for proper safety management was not established. So we recommended that the hospital administration would undertake an early detection and proper management system for hospital precautions, based on QA items & guidelines presented in this study.

  • PDF

Novel Accuracy Enhancement Method for Absolute Temperature Measurement Using TEC-LESS Control in Uncooled Thermal Imaging (비냉각 열상시스템에서 TEC-Less를 이용한 절대온도 측정 정밀도 향상 기법)

  • Han, Joon Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.41-47
    • /
    • 2012
  • Every object over $O^{\circ}K$ emits radiant energy based on its own temperature. Uncooled thermal imaging system displays the detected incident radiant energy as an image by signal processing. Recently, the uncooled thermal imaging system is applied to various areas such as medical, industrial, and military applications. Also, several researches are in progress to find new applications of the uncooled thermal imaging system. In this paper, we present effective method for controlling TEC-less detector in the uncooled thermal imaging system and also present the efficient control scheme for maximizing the accuracy of temperature measurement. The proposed scheme is to apply TEC-less and temperature detection algorithm in Uncooled thermal imaging system. In results of tests performed by using the actual chamber, we acquired images of better quality than the former system and temperature measurement accuracy was improved to less than $1^{\circ}C$.

Assessment technology for spatial interaction of Artificial Monitoring System through 3-dimensional Simulation (3차원 시뮬레이션을 이용한 인위감시체계의 공간대응성능 평가기술)

  • Kim, Suk-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1426-1433
    • /
    • 2015
  • CCTV-applied monitoring is an effective measure to suppress potential crimes and record objective relationship; however, there is no methodology that can quantitatively compare and assess the afore-mentioned effects. Thus, this study intended to construct the methodology and analysis application that can measure the changes in the space-corresponding performance of CCTVs depending on installation measures by using 3-dimenstional virtual simulation technology. For analysis, the raster-based Isovist theory was 3-dimensionally expanded and the amount of incident sight line to each point was accumulated. At the same time, the amount of overlapped monitoring in the CCTV cameras that were connected to each measurement node was accumulated for cross-analysis. By applying the examples and analyzing the results, it was possible to construct an analysis application in use of collision detection model and quantify the changes of monitoring performance depending on positioning alternative of the cameras. Moreover, it enabled intuitive review and supplementation by reproducing visible shadow areas in a graph.

Construction and Validation of Hospital-Based Cancer Registry Using Various Health Records to Detect Patients with Newly Diagnosed Cancer: Experience at Asan Medical Center (의무기록의 다각적 활용을 통한 충실도 높은 병원 암등록 체계의 구축: 서울아산병원의 경험)

  • Kim, Hwa-Jung;Cho, Jin-Hee;Lyu, Yong-Man;Lee, Sun-Hye;Hwang, Kyeong-Ha;Lee, Moo-Song
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.3
    • /
    • pp.257-264
    • /
    • 2010
  • Objectives: An accurate estimation of cancer patients is the basis of epidemiological studies and health services. However in Korea, cancer patients visiting out-patient clinics are usually ruled out of such studies and so these studies are suspected of underestimating the cancer patient population. The purpose of this study is to construct a more complete, hospital-based cancer patient registry using multiple sources of medical information. Methods: We constructed a cancer patient detection algorithm using records from various sources that were obtained from both the in-patients and out-patients seen at Asan Medical Center (AMC) for any reason. The medical data from the potentially incident cancer patients was reviewed four months after first being detected by the algorithm to determine whether these patients actually did or did not have cancer. Results: Besides the traditional practice of reviewing the charts of in-patients upon their discharge, five more sources of information were added for this algorithm, i.e., pathology reports, the national severe disease registry, the reason for treatment, prescriptions of chemotherapeutic agents and radiation therapy reports. The constructed algorithm was observed to have a PPV of 87.04%. Compared to the results of traditional practice, 36.8% of registry failures were avoided using the AMC algorithm. Conclusions: To minimize loss in the cancer registry, various data sources should be utilized, and the AMC algorithm can be a successful model for this. Further research will be required in order to apply novel and innovative technology to the electronic medical records system in order to generate new signals from data that has not been previously used.

A Study on the Effective Countermeasures for Preventing Computer Security Incidents (기업의 침해사고 예방을 위한 관리 모델)

  • Kang, Shin-Beom;Lee, Sang-Jin;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.1
    • /
    • pp.107-115
    • /
    • 2012
  • The level of information protection is relatively low, in comparison with the informatisation in this country. The budget for information protection is also quite marginal at 5% of the entire information-related policy budget. The passive information protection practices by companies, which focus more on the aftermaths, lead to repeated expenses for risk management. The responses to the violation of information protection should be changed from the current aftermaths-oriented focus to prevention and early detection of possible violations. We should also realize that the response to a violation of protected information is not a responsibility of an individual but a joint responsibility of the nation and the industry. South Korea has been working towards to building a systematic foundation since 2004 when guidelines were announced regarding the information protection policy and the safety diagnosis. The current level of safety policies cannot provide a perfect protection against actual violation cases in administrative, technological and physical ways. This research evaluates the level of prevention that the current systematic protection policy offers, and discusses its limitation and possible ways for improvement. It also recommends a list effective measures for protection against information violation that companies can employ to maintain the actual target safety level.

Impact of Solar Irradiance on the Receiver Sensitivity of Free-Space Optical Communication Systems (주광이 무선 광통신 시스템의 수신 감도에 미치는 영향)

  • Park, Gihong;Kim, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.259-267
    • /
    • 2020
  • We evaluate the degradation of receiver sensitivity induced by direct and indirect exposure to solar irradiance in free-space optical communication systems. For this purpose, we calculate the variances of numerous noise components arising from solar irradiance, and then estimate the receiver sensitivity penalties for intensity-modulation/direct-detection and coherent systems. The results show that the penalties are less than 1.3 dB when indirect sunlight impinges on the detector, regardless of the system. However, the sensitivity penalties are estimated to be larger than 30 dB when the sunlight is directly incident upon the receiver. These penalties are barely reduced if we insert an optical polarizer, or if we adjust the bandwidth of an optical filter at the receiver to be as narrow as the signal's bandwidth.

Damage Proxy Map over Collapsed Structure in Ansan Using COSMO-SkyMed Data

  • Nur, Arip Syaripudin;Fadhillah, Muhammad Fulki;Jung, Young-Hoon;Nam, Boo Hyun;Kim, Yong Je;Park, Yu-Chul;Lee, Chang-Wook
    • The Journal of Engineering Geology
    • /
    • v.32 no.3
    • /
    • pp.363-376
    • /
    • 2022
  • An area under construction for a living facility collapsed around 12:48 KST on 13 January 2021 in Sa-dong, Ansan-si, Gyeonggi-do. There were no casualties due to the rapid evacuation measure, but part of the temporary retaining facility collapsed, and several cracks occurred in the adjacent road on the south side. This study used the potential of synthetic aperture radar (SAR) satellite for surface property changes that lies in backscattering characteristic to map the collapsed structure. The interferometric SAR technique can make a direct measurement of the decorrelation among different acquisition dates by integrating both amplitude and phase information. The damage proxy map (DPM) technique has been employed using four high-resolution Constellation of Small Satellites for Mediterranean basin Observation (COSMO-SkyMed) data spanning from 2020 to 2021 during ascending observation to analyze the collapse of the construction. DPM relies on the difference of pre- and co-event interferometric coherences to depict anomalous changes that indicate collapsed structure in the study area. The DPMs were displayed in a color scale that indicates an increasingly more significant ground surface change in the area covered by the pixels, depicting the collapsed structure. Therefore, the DPM technique with SAR data can be used for damage assessment with accurate and comprehensive detection after an event. In addition, we classify the amplitude information using support vector machine (SVM) and maximum likelihood classification algorithms. An investigation committee was formed to determine the cause of the collapse of the retaining wall and to suggest technical and institutional measures and alternatives to prevent similar incidents from reoccurring. The report from the committee revealed that the incident was caused by a combination of factors that were not carried out properly.

Molecular detection and genotype analysis of Kudoa septempunctata from food poisoning outbreaks in Korea

  • Gyung-Hye Sung;In-Ji Park;Hee-Soo Koo;Eun-Hee Park;Mi-Ok Lee
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • Concerns about foodborne illnesses caused by Kudoa septempunctata are steadily growing, but reports of K. septempunctata in clinical and food specimens related to food poisoning in Korea are limited. This study aimed to genetically identify K. septempunctata in patients with acute diarrhea and in clinical and food samples related to food poisoning caused by sashimi consumption. Both real-time and nested polymerase chain reaction assays were performed to detect K. septempunctata 18S and 28S rDNA genes in the stools of 348 patients with acute diarrhea, 11 samples (6 stool and 5 rectal swab samples) from patients with food poisoning, and 2 raw Paralichthys olivaceus samples collected from a restaurant where a food poisoning incident occurred. K. septempunctata was identified in 5 clinical specimens (4 stools and 1 rectal swab) and 1 P. olivaceus sashimi sample. All detected K. septempunctata were of genotype ST3. This is the first study to identify K. septempunctata in both patients and food samples with epidemiological relevance in Korea, providing evidence that it is a pathogen that causes food poisoning. Also, this is the first study to confirm the presence of K. septempunctata genes in rectal swabs. Despite continuing suspected occurrences of Kudoa foodborne outbreaks, the rate of identification of K. septempunctata is very low. One reason for this is the limitation in obtaining stool and vomit samples for the diagnosis of Kudoa infection. We strongly suggest the inclusion of rectal swabs among the diagnostic specimens for Kudoa food poisoning.

Hydrogen sensor using Pt-loaded porous In2O3 nanoparticle structures (백금 담지 다공성 산화인듐 나노입자 구조를 이용한 수소센서)

  • Sung Do Yun;Yoon Myung;Chan Woong Na
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.420-426
    • /
    • 2023
  • We prepared a highly sensitive hydrogen (H2) sensor based on Indium oxides (In2O3) porous nanoparticles (NPs) loaded with Platinum (Pt) nanoparticle in the range of 1.6~5.7 at.%. In2O3 NPs were fabricated by microwave irradiation method, and decorations of Pt nanoparticles were performed by electroless plating on In2O3 NPs. Crystal structures, morphologies, and chemical information on Pt-loaded In2O3 NPs were characterized by grazing-incident X-ray diffraction, field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, respectively. The effect of the Pt nanoparticles on the H2-sensing performance of In2O3 NPs was investigated over a low concentration range of 5 ppm of H2 at 150-300 ℃ working temperatures. The results showed that the H2 response greatly increased with decreasing sensing temperature. The H2 response of Pt loaded porous In2O3 NPs is higher than that of pristine In2O3 NPs. H2 gas selectivity and high sensitivity was explained by the extension of the electron depletion layer and catalytic effect. Pt loaded porous In2O3 NPs sensor can be a robust manner for achieving enhanced gas selectivity and sensitivity for the detection of H2.