• 제목/요약/키워드: In-water cleaning

검색결과 653건 처리시간 0.026초

화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구 (A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process)

  • 신성훈;정종태;조용철
    • 한국수처리학회지
    • /
    • 제26권6호
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구 (The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants)

  • 김선봉;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF

상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정 (Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems)

  • 홍성진;이찬욱;박지승;유도근
    • 한국수자원학회논문집
    • /
    • 제53권11호
    • /
    • pp.1015-1024
    • /
    • 2020
  • 최근 인천, 서울 적수 사고와 같은 관로 내 수질오염 사고가 지속적으로 발생되고 있다. 이러한 수질문제를 인지하기 위해서는 적절한 위치에 수질계측기를 설치하고 미리 계측하여 수용가의 수도꼭지까지 물 공급이 되기 이전에 발견 혹은 차단할 필요가 있다. 그러나 모든 관로에 수질계측기를 다수 설치하는 것에는 유지비용증대와 같은 한계점이 존재한다. 따라서 본 연구에서는 관로 내 수질문제 인지를 위한 유속기반의 수질계측기 설치위치를 결정하고 우선순위를 선정하는 방법론을 제안하였다. 제안된 절차를 관 파괴 시나리오와 국내에서 실제 운영 중인 비상연계관로가 포함된 관망운영 시나리오에 적용해 수질계측기 위치를 결정하고 결과를 분석하였다. 결정 결과 개별적인 관로의 파괴와 비상연계에 의한 비정상상황 발생시 대수용가와 탱크 주변, 그리고 비상연계관로 인근에 위치한 관로의 유속이 급격히 변하여 탁수발생에 의한 수질사고가 나타날 수 있을것으로 나타났다. 제안된 유속기반의 수질계측기 위치 결정 절차는 향후 관 청소를 위한 차단 및 비상관로 운영 계획 수립 등 수질모니터링 지점 선정 기법으로 활용 가능할 것으로 기대된다.

서울시 지하철 구내의 공기중 분진 농도에 관한 연구 (A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area)

  • 백남원;박두용;장익선;신용철;이정인
    • 한국환경보건학회지
    • /
    • 제14권2호
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF

광주지역 바닥분수의 수질특성 평가 (Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju)

  • 김종민;김하람;장서은;최영섭;강유미;정숙경;조영관;김은선
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

도시적 인간상 연구 - 본인 작품을 중심으로- (Human Being in the Contemporary Society)

  • 박성원
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 춘계 종합학술대회 논문집
    • /
    • pp.553-561
    • /
    • 2004
  • 20세기 이후 우리의 경우는 숨가쁘게 유입되는 세계문화와 기존 우리 문화와의 소화 불량적 만남으로 혼돈의 문화를 이룩하였으며, 반도체 수출이나 IT산업에 있어서, 최강의 기술력 보유국(保有國)이라는 자리를 점유하면서도 공허한 심정을 떨칠 수 없게 되었다. 그러한 한국의 현대사와 동시대적 상황 가운데 작금의 현실을 살아가는 우리들은 정치적, 사회적, 문화적 측면에서 혼돈과 현기증을 복합적으로 체감하게 된다. 대중화(大衆化), 소비화(消費化)된 사회는 경제력 향상을 초래(招來)하였으나 그 출발은 익명(匿名)의 대중출현에 의해 가능했으며, 군중(群衆) 속에서의 고독, 소외(疏外), 익명성(匿名性), 몰개성성(沒個性性), 문화의 상품화(商品化) 등의 삶을 동반하고 있다. 본인의 작품에는 이와 같은 사회 현상(現想)들이 도시적 인간상을 통해 드러난다. 소비문화에 노출된 채 그것이 내뿜는 시각 이미지와 유혹에 포위되어 살아가는 인간은 끊임없는 소유욕(所有慾)에 둘러싸여 자신의 가치를 높이기 위한 모든 것을 공간 안에 가둔다. 이들은 몰개성화된 모습으로, 때로는 동물인지 사람인지 알아볼 수 없는 형상으로 도시의 공간에 존재한다. 이는 산업화된 도시의 파괴되어가는 자연 환경을 고발하기 위한 하나의 상징체(象徵體)로서 인간의 소유욕(所有慾)안에 속해있는 제 3의 존재이며 도심속에 갇혀 사는 우리들의 초상화(肖像畵)인 것이다. 본인은 위와 같은 형상을 통하여 현대 도시문명의 현실 속을 살아가는 인간의 객관적 삶과, 익명성(匿名性)에 묻혀 표현되지 못한 욕구와 감정의 대립을 분석해 봄으로써 우리들이 가져야 할 자생성(自生性)과 정체성(停滯性)을 제시하고자 한다.eferences.촉진, 중요 연구 주제의 도출 및 연구 진행 계획을 수립하고, 국제적 산학 협력 강화를 통해 공동 연구를 도출하는 자리를 마련함. $\textbullet$본 학술회의에서 발표된 논문들을 취합하여, 논문집 및 CD-ROM을 제작하여 세계적 수준의 연구 결과를 알리고 이 분야에 관련된 학문, 기술 발전에 큰 도움이 됨.emove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condit

  • PDF

Stain removal on ivory using cyclododecane as a hydrophobic sealing agent

  • 이현숙
    • 고문화
    • /
    • 66호
    • /
    • pp.87-112
    • /
    • 2005
  • Stain removal on ivory has been, for a long time, considered an undesirable treatment in conservation field because ivory is hygroscopic and anisotropic, having different physical properties in different directions. Cyclododecane, which sublimes at room temperature, has been investigated for its use in conservation field since 1995, as a reversible temporary consolidant, sealing agent or coating, water repellent, and barrier layer. This research aims to remove stains on ivory, temporarily protecting the none-stained area or painted area from methanol, acetone or the aqueous cleaning system using cyclododecane as a hydrophobic sealing agent. This research also aims to obtain information regarding whether cyclododecane can be safely and effectively used on archaeological wet ivory. Melted cyclododecane and saturated solutions of cyclododecane in mineral spirits, and hexanes were applied to ivory samples. Application methods, working properties of cyclododecane on ivory, and effect of cyclododecane coating on moisture content of wet ivory were evaluated. The sealing layer formed by molten cyclododecane or by saturated cyclododecane solution in hexane or saturated cyclododecane solution in mineral spirits did not form a secure contact with the surface of the highly polished ivory. The sealing formed with two different layers, in which saturated cyclododecane solution in hexane was applied initially and then molten cyclododecane was applied over the first layer, was found to securely protect the painted area. When the wet samples were kept in 100% RH environments for a month, active mold growths were observed except in the samples sealed with molten cyclododecane. In conclusion, cyclododecane was an efficient hydrophobic sealing agent to protect painting area while cleaning stains on ivory. It also prevented mold growing on wet ivory and wet bone. Evenness of cyclododecane film on ivory will be determined in UV light. Analytical techniques will include visual observation, polarized light microscopy, Scanning Electron Microscope, and Gas Chromatography.

  • PDF

PVDF 가압식과 PE 침지식 분리막을 결합한 2단 막여과 공정의 성능검토 및 회수율 증대 방안 연구 (Increase of Recovery Ratio by Two Stage Membrane Process (the Pressurized PVDF Membrane Followed by Submerged PE Membrane))

  • 김준현;문백수;장홍진;김진호;김병석
    • 멤브레인
    • /
    • 제23권1호
    • /
    • pp.45-53
    • /
    • 2013
  • 현재 분리막 여과 공정은 정수처리에서 많은 관심을 받고 있다. 하지만, 분리막의 효율적인 운영을 위하여 '혼화/응집(/침전)' 등의 전처리 시설 설치로 인한 부지면적 및 비용증가와 5~10%의 배출수 문제가 추가적으로 발생한다. 그래서 본 연구에서는 전처리 공정 없이 지표수(한강)에 대하여 가압식 PVDF 분리막[(주)에코니티]으로 운전하여 성능을 검토하였으며 그 결과 1년 동안 화학적 세정 없이 여과 flux가 1~2.4 m/d (at $25^{\circ}C$)로 운전되었고, 유입원수의 탁도와 상관없이 분리막 처리수의 탁도는 0.05 NTU 이하로 안정되게 유지되었다. 또한, 회수율 제고를 위하여 1개월 동안 가압식 배출수(역세수 + 배수)를 침지식 PE 분리막[(주)에코니티]으로 연계하여 2단 막여과 운영을 한 결과 전체 공정 회수율을 99.5%까지 증가시킬 수 있었다.

Surface modification of polypropylene membrane to improve antifouling characteristics in a submerged membrane-bioreactor: Ar plasma treatment

  • Zhou, Jin;Li, Wei;Gu, Jia-Shan;Yu, Hai-Yin
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.83-92
    • /
    • 2010
  • To improve the antifouling characteristics of polypropylene hollow fiber microporous membranes in a submerged membrane-bioreactor for wastewater treatment, the surface-modification was conducted by Ar plasma treatment. Surface hydrophilicity was assessed by water contact angle measurements. The advancing and receding water contact angles reduced after the surface modification, and hysteresis between the advancing and receding water contact angles was enlarged after Ar plasma treatment due to the increased surface roughness after surface plasma treatment. After continuous operation in a submerged membrane-bioreactor for about 55 h, the flux recovery after water cleaning and the flux ratio after fouling were improved by 20.0 and 143.0%, while the reduction of flux was reduced by 28.6% for the surface modified membrane after 1 min Ar plasma treatment, compared to those of the unmodified membrane. Morphological observations showed that the mean membrane pore size after Ar plasma treatment reduced as a result of the deposition of the etched species; after it was used in the submerged membrane-bioreactor, the further decline of the mean membrane pore size was caused by the deposition of foulants. X-ray photoelectron spectroscopy and infrared spectroscopy confirmed that proteins and polysaccharide-like substances were the main foulants in the precipitate.

첨가제 처리에 의한 과.채류 중 잔류농약 제거효과 연구 (A Study on the Removal Efficiency of Pesticide Residues in Fruits and Vegetables Treated by Additional Materials)

  • 구평태;진성현;강정미;권혁동;박선희;이지윤
    • Applied Biological Chemistry
    • /
    • 제48권4호
    • /
    • pp.388-393
    • /
    • 2005
  • 치커리, 청경채, 방울토마토, 포도 등 과 채류 4종에 Chlorpyrifos, Chlorothalonil, Endosulfan, EPN, Fenitrothion, Procymidone 등 농약 6종을 인위적으로 부착시켜 잔류농약 제거율을 조사한 결과, 수돗물 세척에서 전체 평균 제거율은 68.3%, 수돗물을 이용한 초음파 2분 및 5분간 세척에서 73.7, 82.5%로 나타났고, 4종의 첨가제액를 이용한 세척에서는 0.5% 세제액(82.9%)>5% 식초액(76.9%)>5% 소금물(75.8%)>5% 밀가루액(75.7%) 순으로 나타나 0.5% 세제액이 가장 높은 제거율을 보였으며, 나머지 3종류의 첨가제는 비슷한 제거율을 나타내었다. 첨가제액를 이용한 초음파 세척에서는 첨가제액 세척보다 $1{\sim}3%$ 정도 높게 나타났으며, 0.5% 세제액으로 5분간 초음파 세척시 89.3%로 수돗물 세척보다는 20%정도 높은 제거율을 보였다. 한편 전체 결과에서 최고 및 최저 제거율은 방울토마토중 Chlorthalonil 이 99.0%(0.5%세제 초음파 5분간 세척), 포도 중 EPN이 47.8%(물세척)로 나타났고, 농약별로는 Chlorthalonil(90.0%)>Procymidone(81.3%)>Chlorpyrifos(76.6%)>Endosulfan(75.7%)>Fenitrothion(75.5%)>EPN(73.8%) 순으로 높은 제거율을 보였다.