• Title/Summary/Keyword: In-water cleaning

Search Result 652, Processing Time 0.032 seconds

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Development of an automated system for water-hydraulic and leakage test of pressure vessels

  • Kim, Dong-Soo;Lee, Won-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • This study developed a fully automated test system for pressure vessels, containing such as oxygen, nitrogen, which is widely used in many industries. The pressure vessel test has three major parts including weight measurement test, water-hydraulic test and leakage test followed by cleaning and drying. The control system for these tests consists of three parts: a PLC, a monitoring system and a database management system. The PLC oversees overall control of test machines, while the monitoring system measures and displays weight, pressure, flow etc. for every situations, and the database management system stores test data. These three modules are designed to communicate with one another at 1 Hz frequency alerting problematic situations to the operator. The system has gone through actual field tests for verification of performances.

Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement (회전자 고정자권선의 절연보수후 절연특성변화 연구)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

Experimental Study on Synthetic Fiber Filled Channel for Treating Turbid Water at the Construction Sites and Protecting Drain System (합성섬유 충진 여과수로를 이용한 건설사업장의 흙탕물 처리 및 배수구 보호에 관한 실험적 연구)

  • Yuan, Qingke;Cheng, Jing;Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.537-545
    • /
    • 2016
  • In order to cope with the new and strict government regulations for turbid water discharge from construction sites, this study tested whether synthetic fiber filters can replace conventional best management practices. The filter efficiency was about 10 to 60% with a varying filter depth of 5 to 15cm, presuming extreme storm flow conditions to be in the range of 800 to 1500m/day of filtration rates. Fiber filter acts exactly like a granular filter, i.e. the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. Based on the operational data, we suggested the Log-Log design relationship, which can be used to determine the filter depth and area. Compared to the widely used gravel filter which treats the turbid water at the construction site, about 20% higher efficiency was obtained under similar operating conditions. Cleaning the filter through a simple hand-washing method at the time of break-through, achieved about 90% soil recovery.

Dyeing of Silk with Chinese Scholar Tree Extract (괴화추출물에 의한 견섬유의 염색성)

  • 배정숙;김성숙
    • Textile Coloration and Finishing
    • /
    • v.12 no.3
    • /
    • pp.183-191
    • /
    • 2000
  • The dyeing of silk fabric with chinese scholar tree extract was investigated. The colorant was extracted with distilled water, and concentrated under reduced pressure, and, finally spray-dried. The optimum temperature and dyeing time for the dyeing of silk with the scholar tree extract was $60^\circ{C}$ and 60 minutes respectively. In mordant dyeing, pre-mordanting method was most effective for color yield, and 1~2 % of mordant concentration was acceptable. Fastness of the dyed silk fabric to laundering and rubbing was shown to be good, but fastness to light, dry cleaning, and perspiration were varied with used mordants.

  • PDF

Flotation for Recycling of a Waste Water Filtered from Molybdenite Tailings (몰리브덴 선광광미 응집여과액 재활용을 위한 부유선별 특성)

  • Park, Chul-Hyun;Jeon, Ho-Seok;Han, Oh-Hyung;Kim, Byoung-Gon;Baek, Sang-Ho;Kim, Hak-Sun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.235-242
    • /
    • 2010
  • Froth flotation using the residual water in the end of flotation process has been performed through controlling of pH. IEP (isoelectric point) of molybdenite and quartz in distilled water was below pH 3 and pH 2.7, respectively and the stabilized range was pH 5~10. In case of a suspension in reusing water, zeta potential of molybdenite decreased to below -10 mV or less at over pH 4 due to residual flocculants. As result of pH control, flotation efficiency in the alkaline conditions was deteriorated by flocculation, resulting from expanded polymer chain, ion bridge of the divalent metal cations ($Ca^{2+}$), and hydrophobic interactions between the nonpolar site of polymer/the hydrophobic areas of the particle surfaces. However, the weak acid conditions (pH 5.5~6) improved the efficiency of flotation as hydrogen ions neutralize polymer chains and then weakened its function. In cleans after rougher flotation, the Mo grade of 52.7% and recovery of 90.1% could be successfully obtained under the conditions of 20 g/t kerosene, 50 g/t AF65, 300 g/t $Na_2SiO_3$, pH 5.5 and 2 cleaning times. Hence, we developed a technique which can continuously supply waste water filtered from tailings into the grinding-rougher-cleaning processes.

An Experimental Study of Operating Characteristics on Fouling Auto Removal Apparatus of Multi Pass Type Heat Exchanger using Ejector (이젝터를 이용한 다관식 열교환기 파울링 자동제거장치의 구동특성에 관한 실험적 연구)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.63-69
    • /
    • 2009
  • The experiment was performed to check operating characteristics of fouling auto removal apparatus for multi pass type heat exchanger using ejector. The results showed as following. The ejector suction flow rate increased with the head of operating pump of ejector. Proper suction flow rate showed $7.2{\sim}10.2m^3/h$ for ball collection in case of pump head 35~50m. The head of ejector outlet pipe is below 4.1m in case of 40m, the head of operating pump of ejector to confirm ejector suction flow rate 8.4m3/h. Lattice space of ball separator is allowed 6~10.3mm in ranges of ball diameter are 15~25mm and when mass flow of cooling water is 3.0m/sec. Average of passing time of balls is 1.2~2.8sec depend on the velocity of flow and the size of balls.

  • PDF

A Study on the Low-energy Large-aperture Electron Beam Generator (저에너지 대면적 전자빔 발생장치 개발에 관한 연구)

  • Jo, Ju-Hyeon;Choe, Yeong-Uk;Lee, Hong-Sik;Im, Geun-Hui;U, Seong-Hun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.785-790
    • /
    • 1999
  • This research has been carried out to develop a low-energy large-aperture pulsed electron beam generator (LELA), 200keV 1A, for industrial applications. One of the most important feature of this electron beam generator is large electron beam cross section of $190cm^2$. Low energy electron beam generators have been used for water cleaning, flue gas cleaning, and pasteurization, etc. In these applications the cross sectionof the e-beam is related to reaction efficiency. Another important feature of this LELA EB generator is easy maintenance because of its simple structure and relatively low vacuum operation compared to the conventional EB generators. The conventional EB generators need to be scanned because the small cross section thermal electron emitters are used in the conventional EB generators which have small EB cross section. In this research, we use the secondary electrons generated by ion bombardment on the HV cathode surface as a electron source. Therefore we can make any shape of EB cross section without scanning.

  • PDF

The Control Method of Scale in Drainage Pipe of Deteriorated Tunnel used Magnetic Field and Quantum Stick (자화장치와 퀀텀스틱을 이용한 노후터널의 배수공내 침전물 방지 방법)

  • Nam, Joongwoo;Lee, Changgi;Lee, Jonghwi;Do, Jongnam;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.59-64
    • /
    • 2011
  • Clogging in drainage pipe is one of the important problems, so it needs a remedy urgently. Recently, scale in drainage pipe is removed by water jet cleaning and other treatment. But these treatments need much cost and regular management. The principal component of scale in drainage pipe is $CaCO_{3}$. It was observed the setting of $CaCO_{3}$ by some kind of analysis such as SEM, XRD, visual and weight measuring analysis to solve these problems and prevent setting formation in drainage pipe. As a result, in case of magnetic, particle shape of $CaCO_{3}$ is changed Aragonite from Calcite. Also in case of Quantum Stick, the amount of scale is reduced by expert inspector's result. As a whole, Magnetic treatment and Quantum Stick have the effect for protecting of scale precipitation.