Scientific Preservation of the Relics left by the Fallen Heroes of the Korean War: Focusing on the Local Relics Kept by the Ground Operations Command (6·25전쟁 전사자 유품의 과학적 보존: 지상작전사령부 소장 지역유품 중심으로)

  • Park, Min-Seon;Oh, Seung-Jun;Lee, Ho-Yeon;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.38 no.2
    • /
    • pp.144-153
    • /
    • 2022
  • This study conducted scientific analysis and preservation treatment for the local 7 relics (depurator bottle, eagle patten button, rank insignia, mess tin, M1 Grand-gun cleaning tool kit, Carbine bullet, cartridge) of the fallen of Korean War excavated through the MND Agency for KIA Recovery & Identification that are possessed in the exhibition hall of the Ground Operations Command. FT-IR analysis results show that remainder of depurator bottle is assumed to play a role of water and food purifier during the war for its spectrum similar to Trisodium phosphate, and inscription carved on the cartridge that is hard to observe with naked eyes was also confirmed through 3D digital shooting method. This study also established directivity of preservation treatment of relics for stable treatment by carrying out a survey of conditions based on the microscope and visual observation. The result is expected to be used as basic data for establishment of future directivity of preservation treatment for a variety of war relics.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

A Survey on Hanwoo Calf Management Prior to Weaning (이유전 합리적인 송아지 사양관리를 위한 한우농가 송아지 사양관리 실태 조사)

  • Yeo, Joon-Mo;Lee, Sung-Hoon;Ki, Kwang-Seok;Hwang, Jin-Ho;Lee, Sung-Sill;Kim, Wan-Young
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.141-147
    • /
    • 2012
  • The present survey was conducted to provide basic information on Hanwoo calf management. Eight hundred and sixty-two Hanwoo breeding farms from all nine provinces were surveyed via personal interviews. The percentages of farms categorized by herd size were 30.5%, 32.8%, 26.0% and 10.7% for <50 heads, 51-100 heads, 101-200 heads, and >200 heads, respectively. More than 50% of farms offered calf starter at 6-10 days of age, showing that calf starter was offered relatively at an earlier age. Calf starter was replaced every three days by 30.1% of farms. The percentages of farms replacing starter weekly (19.2%) were even higher than those of replacing starter daily (18.8%), suggesting that the frequency of replacing starter needs to be increased to maintain starter freshness and to increase starter intake. About one-third of farms offered forage at 6-10 days of age and 21% of farms offered even at 1-5 days of age although it has been well known that forage does not contain either nutrient density or nutrient profile necessary to stimulate rumen papillae development, especially before weaning. Furthermore, about half of farms used rice straw with calf starter. Water was offered relatively at an earlier age (1-5 days of age) by 55% of farms. Deciding when to wean calves should be based on starter intake rather than age but less than 50% of farms decided weaning age by starter intake. In conclusions, to reduce weaning age of Hanwoo calves by rapid rumen papillae development it is necessary to provide fresh starter and water by increasing frequency of starter replacing and water trough cleaning and not to feed forage before weaning.

Phase Behavior Study of Fatty Acid Potassium Cream Soaps (지방산 칼륨 Cream Soaps 의 상거동 연구)

  • Noh, Min Joo;Yeo, Hye Lim;Lee, Ji Hyun;Park, Myeong Sam;Lee, Jun Bae;Yoon, Moung Seok
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.1
    • /
    • pp.55-64
    • /
    • 2022
  • The potassium cream soap with fatty acid called cleaning foam has a crystal gel structure, and unlike an emulsion system, it is weak to shear stress and shows characteristics that are easily separated under high temperature storage conditions. The crystal gel structure of cleansing foams is significantly influenced by the nature and proportion of fatty acids, degree of neutralization, and the nature and proportion of polyols. In order to investigate the effect of these parameters on the crystal gel structure, a ternary system consisting of water/KOH/fatty acid was investigated in this study. The investigation of differential scanning calorimeter (DSC) revealed that the eutectic point was found at the ratio of myristic acid (MA) : stearic acid (SA) = 3 : 1 and ternary systems were the most stable at the eutectic point. However, the increase in fatty acid content had little effect on stability. On the basis of viscosity and polarized optical microscopy (POM) measurements, the optimum degree of neutralization was found to be about 75%. The system was stable when the melting point (Tm) of the ternary system was higher than the storage temperature and the crystal phase was transferred to lamellar gel phase, but the increase in fatty acid content had little effect on stability. The addition of polyols to the ternary system played an important role in changing the Tm and causing phase transition. The structure of the cleansing foams were confirmed through cryogenic scanning electron microscope (Cryo-SEM), small and wide angle X-ray scattering (SAXS and WAXS) analysis. Since butylene glycol (BG), propylene glycol (PG), and dipropylene glycol (DPG) lowered the Tm and hindered the lamellar gel formation, they were unsuitable for the formation of stable cleansing foam. In contrast, glycerin, PEG-400, and sorbitol increased the Tm, and facilitated the formation of lamellar gel phase, which led to a stable ternary system. Glycerin was found to be the most optimal agent to prepare a cleansing foam with enhanced stability.

Changes in Characteristics of Semi-cured Pig Manure Liquid Fertilizer according to the Storage Duration and Aeration (반부숙상태 돈분뇨 액비의 저장기간 및 폭기여부에 따른 특성 변화)

  • Jeong, Kwang-Hwa;Park, Hoe-Man;Lee, Dong-Jun;Kim, Jung-Kon;Kim, Hyunjong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.109-122
    • /
    • 2022
  • Currently, most of the pig manure generated from pig farms in Korea is in the form of a slurry with a moisture content of about 97%. Pig manure slurry is a mixture of pig manure and cleaning water in the pig house. In this study, changes in properties of pig manure liquid fertilizer according to whether air was supplied or not and with the passage of storage period were analyzed for 120 days. During the experimental period, the degree of maturity of the pig manure liquid fertilizer was higher in the experimental closed batch reactors supplied with air than in the same type reactors not supplied with air. As the liquid fertilizer storage period elapsed, there was a tendency that liquid fertilizer was converted to a state of complete maturity. In the batch reactor in which air was supplied, the moisture content of pig manure slurry, which had a moisture content of 97.90%, was reduced to 96.82% at the end of the experiment. On the other hand, the moisture content in the reactor without air was reduced to 97.33%. The pH of the liquid fertilizer, which was 8.82 at the start of the experiment, changed to 7.57 in the reactor with air supplied and 8.75 in the reactor without air at the completion of the experiment. The nitrogen content in the liquid fertilizer was 0.198 mg/L on average at the start of the experiment and it was lowered to 0.076 mg/L in the air supplied reactor at the end of the experiment. On the other hand, the nitrogen content of the liquid fertilizer was lowered to 0.121 mg/L in the reactor to which air was not supplied. The phosphoric acid (P2O5) concentration in the liquid decreased higher in the liquid fertilizer filled in the reactor without air than the liquid fertilizer filled in the reactor with air supplied as the storage period elapsed. Considering the experimental results, it is considered that the quality of pig manure liquid fertilizer is improved when air is supplied to pig manure slurry and the storage period of pig manure slurry is longer.

A Study on the Nonpoint Pollutant Loadings in Urban and Agricultural Areas (도시(都市)와 농촌(農村)에서의 비점원(非點源) 오염물(汚染物) 배출양상(排出樣相)에 관한 연구(硏究))

  • Lim, Bong Su;Lee, Byung Hyun;Choi, Eui So
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.2
    • /
    • pp.45-53
    • /
    • 1984
  • This study was conducted to investigate characteristics of nonpoint pollutant discharges and concentrations in runoff from the urban and agricultural areas in Korea. The analytical parameters used for this study were COD, BOD and SS. This study was conducted during the period from May to August 1981. Nonpoint pollutant mass loadings from the urban area were influenced by the rainfall intensity and the duration of rainfall, and etc. The concentrations of pollutants in the first flush was higher as the discharges increased. It was, however, found that the concentrations of pollutants in the heavy storm runoff were decreased due to the dilution effect. When other rainfall followed a peak rainfall, the concentrations of pollutants were lower than expected, because the first flush conveyed the most of pollutants deposited on the combined sewers. However the concentrations were increased in proportion to the increased flow when a rainfall of higher intensity than the first flush was continued. Yearly area yield rates in kg/ha were estimated to be 690.5(489.9~1,328) of COD, 319.7(226.8~614.8) of BOD, and 831.2(589.7~1,598) of SS. Pollutant sources in agricultural area were of the domestic waste water, manure composting stack, and agricultural solid wastes and etc. In the paddy field, yearly area yield rates in kg/ha were estimated to be 623.4(21.7~114) of COD, 18.65(9.53~34.5) of BOD, and 91.9(46.3~171.8) of SS. In the crop land, however, yearly rates in kg/ha were estimated to be 91.9(46.3~171.8) of COD, 23.09(11.7~42.5) of BOD, and 23.09(11.4~43.4) of SS. Pollutant sources in the feedlot area were originating from the feces of cattle, the cleaning water, the wastes spilled from manure composting stack during rain. Yearly area yield rate in kg/ha was estimated to be 3.804(2,489~6,658) of COD, 2.047(464~2,900) of BOD, and 1.149 (729~1,442) of SS. Pollutant discharges in the forest area were resulted from the organic layer like leaves and others deposited on the surface. Yearly area yield rate in kg/ha was estimated to be 9.86(5.45~18.56) of COD, 3.48(1.67~7.54) of BOD, and 4.64(9.74~10.35) of SS.

  • PDF

Dietitians' Perception of Importance about Standards of Foodservice Management Associated with Long-Term Care Hospital Accreditation (요양병원 인증제 관련 급식관리 기준에 대한 영양사들의 중요성 인식도)

  • Lee, Joo-eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1558-1566
    • /
    • 2015
  • The purpose of this study was to examine dietitians' perception of importance about standards of foodservice management associated with long-term care hospital accreditation. This study was carried out through a postal survey consisting of 500 questionnaires, and 157 returned questionnaires were used in the statistical analysis. The results were summarized as follows. Average scores of perception of importance were 4.54/5 points in foodservice production management domain, 4.56/5 points in foodservice facilities management domain, and 4.70/5 points in foodservice sanitation domain. The average scores of importance of long-term care hospitals without accreditation were significantly (P<0.05) lower than those of hospitals with accreditation in items of 'establishment of ventilation equipment in kitchen', 'establishment of hand-washstand in toilet (warm-water, soap)', 'setup of sterilizing foothold in entrance of kitchen and toilet', 'division and use of knife, chopping board, gloves, and utensils before and after cook', 'establishment of cleaning plan and cyclic practice', and 'recording of receiving diary'. Results indicate that there is a need to supplement a casebook of regulations by suggesting detailed and critical limits in the case of below average points of importance. A manual, including HACCP standards for foodservice management of long-term care hospitals, is needed, along with education and webpage for comparing notes on accreditation of long-term care hospitals.

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.

A Study on the Fouling of Ultrafiltration Membranes Used in the Treatment of an Acidic Solution in a Circular Cross-flow Filtration Bench (순환식 막 모듈 여과장치를 이용한 산성용액의 수처리 공정 시 발생하는 한외여과막 오염에 관한 연구)

  • Kim, Nam-Joon;Choi, Chang-Min;Choi, Yong-Hun;Lee, Jun-Ho;Kim, Hwan-Jin;Park, Byung-Jae;Joo, Young-Kil;Kang, Jin-Seok;Paik, Youn-Kee
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.252-260
    • /
    • 2009
  • The effects of the treatment of an acidic solution at pH 2 on polyacrylonitrile ultrafiltration (UF) membranes were investigated using a circular cross-flow filtration bench with a membrane module. A substantial reduction in the membrane permeability was observed after 80 hours' treatment of the acidic solution. In addition, the analyses of the sample solutions by ultraviolet/visible absorption spectroscopy and gas chromatography/mass spectrometry (GC/MS), which were taken from the feed tank as a function of the treatment time, showed that a new organic compound was produced in the course of the treatment. From a thorough search of the mass spectral library we presumed the new compound to be 1,6-dioxacyclododecane-7,12-dione (DCD), one of the well-known additives for polyurethane. Based on further experimental results, including the scanning electron microscope (SEM) images and the solid-state NMR spectra of the membranes used for the treatment of the acidic solution, we suggested that the decrease of the permeate flux resulted not from the deformation of the membranes, but from the fouling by DCD eluted from the polyurethane tubes in the filtration bench during the treatment. Those results imply that the reactivity to an acidic solution of the parts comprising the filtration bench is as important as that of the membranes themselves for effective treatments of acidic solutions, for efficient chemical cleaning by strong acids, and also in determining the pH limit of the solutions that can be treated by the membranes.

Evaluation and Reduction of Microbiological Hazard of Spoon and Spoon Case Carried by Nursery School Children (어린이집 유아 휴대 수저 및 수저집의 미생물학적 위해 분석 및 저감화)

  • Kim, Jung-Beom;Park, Yong-Bae;Kim, Ki-Cheol;Kim, Dae-Hwan;Kang, Suk-Ho;Lim, Young-Sik;Park, Po-Hyun;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.1
    • /
    • pp.116-122
    • /
    • 2011
  • This study was conducted to investigate the microbiological hazard of spoons and their cases carried by nursery school children and to evaluate the reduction effects of washing methods and ultraviolet (UV) treatments against Escherichia coli on the spoon and spoon case. A total of 78 spoons and their cases were sampled to test about total aerobic bacteria, coliform bacteria, Staphylococcus aureus, Bacillus cereus and Salmonella spp. Total aerobic bacteria were detected over 2.7 log CFU/100 $cm^2$ in 20 out of 36 spoons (55.6%), 9 out of 20 zipper-type spoon cases (45.0%) and 13 out of 22 plastic-type spoon cases (59.1%). Coliform bacteria were also detected in 19 out of 36 spoons (52.8%), 14 out of 20 zipper-type spoon cases (70.0%) and 14 out of 22 plastic-type spoon cases (63.6%). The pathogens tested in this study were not found in all samples except for the zipper-type spoon cases which were contaminated with Staph. aureus (2 samples) and B. cereus (3 samples). The results indicated that the sanitary conditions of spoons and their cases should be improved promptly. To evaluate the reduction effects of washing methods and UV treatments against E. coli, the spoons and their cases were treated at different cleaning times with and without soap, and different UV exposure times, respectively. E. coli with initial cell number of 4 log CFU on the spoons and their cases was not detected when they were cleaned at running water for 30 sec after dish sponging with soap for 30 sec. In UV treatments, E. coli with the same level of washing method was not detected after UV exposure for 15 minute in the spoons and their cases. From the results, the washing and UV treatment should be used to control the microbial contamination of spoons and their cases for more than 1 and 15 minutes, respectively.